Filtering - 1

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES TECHNICAL CHARACTERISTICS OVERVIEW : The PP 30F (rear connection) and PP 31F (side connection) are employed for the diffusion of air using absolute filters in white rooms, hospitals, pharmaceutical labs, food industries and generally in buildings with controlled contamination. TECHNICAL CHARACTERISTICS: Here below are shown the main size characteristics. For the absolute filter class indicated, refer to the relevant page. CONSTRUCTION CHARACTERISTICS Supporting frame: the filter holding plenum is made from folded steel plate, welded and varnished RAL 9010 both internally and externally or stainless steel; the construction is made completely air tight, complete with connection for the air supply. On request the unit can be made in stainless steel (special construction). Fixing of the grille using screws and filleted inserts applied on the side of the plenum. Supply grille: double deflection blades individually adjustable, in anodized extruded aluminium. On request this can be supplied in a RAL colour chosen from the customer. Air entrance: rear or lateral with circular connector. Installation: the fixing profile has been designed specifically to allow for fixing to walls. The removal of the grille for the substitution of the filter can be done without removing the entire filter holding unit.

Open the catalog to page 1
Filtering - 2

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES j F absolute filter holder PP30F550400 Plenum with absolute filter holder lateral connection 550x400 UM2VF550400 Ventilation grille double deflection vertical/horizontal 550x400

Open the catalog to page 2
Filtering - 3

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES HOW TO ORDER Plenum nominal dimensions Absolute filter plenum wit rear connection Double deflection supply grille Absolute filter plenum wit rear connection Double deflection supply grille Absolute filter Plenum nominal dimensions

Open the catalog to page 3
Filtering - 5

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS OVERVIEW TECHNICAL CHARATTERISTICS OVERVIEW : The FY series of terminals is used for diffusing air through absolute filters for white chambers, medical centres, pharmaceutical laboratories, the food industry and generally in any contamination-controlled environment. The FY series of diffuser terminals can be fitted with various types of diffusers, depending on the type of diffusion required, that is, the slotted diffusers may be used for laminar airflows and panel or 4-outlet diffusers for turbulent airflows. FA Filter with gasket CONSTRUCTION...

Open the catalog to page 5
Filtering - 6

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 6
Filtering - 7

ABSOLUTE FILTER HOLDER TERMINAL FY 10 - 4N - APA - 305

Open the catalog to page 7
Filtering - 8

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 8
Filtering - 9

ABSOLUTE FILTER HOLDER TERMINAL FY 21 - KN - APA - 457

Open the catalog to page 9
Filtering - 10

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 10
Filtering - 11

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 11
Filtering - 12

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 12
Filtering - 13

ABSOLUTE FILTER HOLDER TERMINAL DIFFUSERS

Open the catalog to page 13
Filtering - 14

ABSOLUTE FILTER HOLDER -1 FY Absolute filter holder terminal N4 four ways diffuser KN4 I- P whith flat damper F with perfored damper A lateral circular connection B upper circular connection

Open the catalog to page 14
Filtering - 15

FILTER MEDIA OVERVIEW - TECHNICAL CHARACTERISTICS MEDIUM EFFICENCY FILTERS OVERVIEW : FR series filter media are made of fiber glass. They are used for spry booth, paint field application and prefiltration of rough dusts. Furthermore FR filter media is suitable for application on filter-holder extract grilles. They are supplied in rolls or panels. FILTER MEDIA : fire retardant and water-repellent fiber glass with progressive density. OPERATIVE TEMPERATURE : + 100 C. HEIGHT FILTER MEDIA : 2000 mm. Filtering class - Am% on synthetic dust Packing weight[kg] G3 Initial Δp Final Δp Maximum Δp...

Open the catalog to page 15
Filtering - 16

FLAT FILTERING CELLS OVERVIEW - TECHNICAL CHARACTERISTICS MEDIUM EFFICENCY FILTERS OVERVIEW : The flat filtering cell FP series is used for primary filtration in HVAC plant when pre-filtration of rough and fine dusts is required. Furthermore FP filters are suitable for application on filter-holder extract grilles. FILTER MEDIA : made of polyester fiber. FRAME : made of galvanized steel and protective mesh screen on both sides. OPERATIVE TEMPERATURE : - 30 + 100 C. HEIGHT FILTERING ELEMENT : 22 - 48 mm.. Filtering class - Am% on synthetic dust CODE EXAMPLE Flat filter cell sizes 592x592,...

Open the catalog to page 16
Filtering - 17

PLEATED FILTERING CELL OVERVIEW - TECHNICAL CHARACTERISTICS MEDIUM EFFICENCY FILTERS OVERVIEW : The pleated filtering cell FO series is used for primary filtration in HVAC plant when pre-filtration of rough and fine dusts is required. Furthermore FP filters are suitable for application on filter-holder extract grilles. FILTER MEDIA : made of polyester fiber. FRAME : made of galvanized steel and protective mesh screen on both sides. OPERATIVE TEMPERATURE : - 30 + 100 C. HEIGHT FILTERING ELEMENT : 48 - 98 mm. Filtering class - Am% on synthetic dust CODE EXAMPLE Pleated filter cell sizes...

Open the catalog to page 17
Filtering - 18

STAINLESS STEEL FLAT FILTER OVERVIEW - TECHNICAL CHARACTERISTICS MEDIUM EFFICENCY FILTERS OVERIVIEW : The pleated filtering cell FPI series is used for primary filtration in cooking area plant and when aspiration of kitchen vapours and smokes removal is required. FILTER MEDIA : The media is constituted by multilayer nets with variable density of stainless steel. FRAME : AISI 304 stainless steel. OPERATIVE TEMPERATURE : + 200 C. HEIGHT FILTERING ELEMENT : 12,5 - 22 mm. EU 2 EN779 (G2) Filtering class CODE EXAMPLE Flat filter cell sizes 400x400, filtering class EU2 and filtering element...

Open the catalog to page 18
Filtering - 19

RIGID FILTER BAGS OVERVIEW - TECHNICAL CHARACTERISTICS HIGH EFFICENCY FILTERS The FTR Series units are hard pocket filters. They are used for micro dusts filtering in the air-treatment installations for dwelling houses, general laboratories, hospitals, telephone and data processing stations. They also are used as absolute filters prefilterings. Filtration class from F6 to F9 Contructins with two, three or four bags Air flow from 1700m³/h to 4250 m³/h Material folded glass fiber paper Containment frame of plastic material Separator wire thermoplastic Sealing Polyurethane Max temperature +70...

Open the catalog to page 19

All MP3 catalogs and technical brochures

  1. UV SERIES

    6 Pages

  2. FLEXIBLE DUCTS

    18 Pages

  3. TT Series

    6 Pages

  4. SA2 Series

    5 Pages

  5. SAC Series

    5 Pages

  6. XRC Series

    26 Pages

  7. XXP Series

    4 Pages

  8. XTE Series

    2 Pages

  9. AS-TN Series

    6 Pages

  10. XZO Series

    4 Pages

  11. XE Series

    2 Pages

  12. XZJ Series

    2 Pages

  13. XSR Series

    4 Pages

  14. FTR Series

    2 Pages

  15. FA Series

    2 Pages

  16. FP

    1 Pages

  17. FTF

    2 Pages

  18. XUM

    4 Pages

  19. XLA-C

    2 Pages

  20. XLF

    6 Pages

  21. diffusion

    30 Pages

  22. VAV and CAV

    82 Pages

  23. Regulation

    38 Pages

  24. Recuperators

    26 Pages

  25. Humidifiers

    6 Pages

  26. Fans

    58 Pages

  27. Silenciers

    20 Pages

Archived catalogs

  1. silencers

    20 Pages

  2. VAV & CAV

    48 Pages

  3. diffusion

    132 Pages

  4. regulation

    20 Pages

  5. fans

    32 Pages

  6. recuperators

    6 Pages