Fans - 1

TECHNICAL CHARACTERISTICS The XXE Series ventilation units are formed by the box and the centrifugal fan with a direct coupled electric motor. Air flow rates between 100 and 4.600 m³/h Galvanized carbon steel sheet panels box structure Sideway panel with function of inspection door Suction with circular operning Monophase three speeds motor direct coupled Supporting motor-board formed by proper soundproof cages and buffers Double aspiration centrifugal fan Fan fixing to the structure by vibrationproof joints. Fluid dynamic performance measured in accordance with ISO 5801:2007.

Open the catalog to page 1
Fans - 2

TECHNICAL CHARACTERISTICS

Open the catalog to page 2
Fans - 3

SELF-SUPPORTING BOX FANS ON GUIDES TECHNICAL CHARACTERISTICS The XXP double inlet centrifugal fan is made up of a soundproof box, and a centrifugal fan with direct drive motor. - The self-supporting structure of the soundproof casing is made of galvanised steel sheet. A side panel, with a closing device that conforms to EEC standards, serves as an inspection hatch. - The double inlet, direct drive fan uses a conventional motor, which is supported in the centre of an inlet cone by means of an adequate support caging and anti-vibration pads. Galvanised steel scroll, fan and motor supporting...

Open the catalog to page 3
Fans - 4

SELF-SUPPORTING BOX FANS ON GUIDES TECHNICAL CHARACTERISTICS The boxed ventilators are generally not supplied with an aspiration opening. This must be obtained from the installer in the required point and dimensions of the duct. All boxed ventilators are supplied with the use and instructions manual complete of certificate of conformity.

Open the catalog to page 4
Fans - 5

SELF-SUPPORTING BOX FANS ON GUIDES Fan units with additional soundproofing XXP 1 IA XXP 2 IA XXP 3 IA XXP 4 IA XXP 5 IA XXP 6 IA XXP 7 IA XXP 8 IA XXP 9 IA XXP 10 IA XXP 11 IA XXP 12 IA XXP 13 IA XXP 14 IA XXP 15 IA Fan unit with direct drive motor Fan type Additional soundproofing Exhaust stubpipe Regulating damper Regulator for single-phase motor (4 A) Regulator for three-phase motor (6 A) Regulator for single-phase motor (9 A) Exhaust stubpipe Rain cover XTEXP 1 XTEXP 2 XTEXP 3 XTEXP 4 XTEXP 5 XTEXP 6 XTEXP 7 XTEXP 8 XTEXP 9 XTEXP 10 XTEXP 11 XTEXP 12 XTEXP 13 XTEXP 14 XTEXP 15 Regulator...

Open the catalog to page 5
Fans - 7

BOXED FANS WITH LOADBEARING STRUCTURE TECHNICAL CHARACTERISTICS The XXS double-inlet centrifugal fan is made up of a soundproof caging and a direct drive motor centrifugal fan. - The supporting structure of the soundproof caging is made up of an aluminium frame and of single or double panels in galvanised or stainless steel sheet. A side panel, fitted with a closing device that conforms to EEC standards, serves as an inspection hatch. - The double inlet, direct drive fan uses a conventional motor, which is supported in the centre of an inlet cone by means of an adequate support caging and...

Open the catalog to page 7
Fans - 8

BOXED FANS WITH LOADBEARING STRUCTURE TECHNICAL CHARACTERISTICS The boxed ventilators are generally not supplied with an aspiration opening. This must be obtained from the installer in the required point and dimensions of the duct. All boxed ventilators are supplied with the use and instructions manual complete of certificate of conformity.

Open the catalog to page 8
Fans - 9

BOXED FANS WITH LOADBEARING STRUCTURE Exhaust stubpipe XTAXS1 XTEXS1 XTAXS2 XTEXS2 XTAXS3 XTEXS3 XTAXS4 XTEXS4 XTAXS5 XTEXS5 XTAXS6 XTEXS6 XTAXS7 XTEXS7 XTAXS8 XTEXS8 XTAXS9 XTEXS9 XTAXS10 XTEXS10 XTAXS11 XTEXS11 XTAXS12 XTEXS12 XTAXS13 XTEXS13 XTAXS14 XTEXS14 XTAXS15 XTEXS15 XXS Ventilation unit wit directly coupled motor n Ventilator type IA Additional sound insulation XTE XP Expulsion bracket WM-10 Regulation damper XSR-M04E Regulator for single phase motor (4 A) XSR-M06E Regulator for single phase motor (6 A) XSR-M09E Regulator for single phase motor (9 A) XSR-T06E regulator for single...

Open the catalog to page 9
Fans - 11

BELT DRIVEN BOX FANS TECHNICAL CHARACTERISTICS The XXK series of double-inlet centrifugal fans is made up of a soundproof casing, a fan and a motor. - The supporting structure of the soundproof casing is made up of an aluminium frame and single or double side panels in galvanised or stainless steel sheet. The panel on the drive side is fitted with a closing device that conforms to EEC standards, and serves as an inspection hatch. The fan and electric motor are mounted on a system of slides, resting on anti-vibration bearings. - The scroll and centrifugal fan are made of galvanised steel...

Open the catalog to page 11
Fans - 12

BELT DRIVEN BOX FANS TECHNICAL CHARACTERISTICS The boxed ventilators as standard are not supplied with aspiration opening. This must be made from the installer in the required position and dimension of the duct. All the boxed ventilators are accompanied with an instructions manual that included the declaration of conformity.

Open the catalog to page 12
Fans - 13

BELT DRIVEN BOX FANS XXK IA Unit with additional soundproofing Stainless steel panel Double panel Belt driven ventilation unit Ventilator type XXK unit with soundproof insulation Stainless steel panel Double panel Rain protecting top Extraction connector Regulation damper Speed regulation with inverter on request

Open the catalog to page 13
Fans - 15

BELT DRIVEN BOXED VENTILATORS SQUARE MOUTH TECHNICAL CHARACTERISTICS The XXT series of double-inlet centrifugal fans is made up of a soundproof casing, a fan and a motor. - The supporting structure of the soundproof casing is made up of an aluminium frame and single or double side panels in galvanised or stainless steel sheet. The panel on the drive side is fitted with a closing device that conforms to EEC standards, and serves as an inspection hatch. The centrifugal fan and electric motor are mounted on a system of slides, resting on anti-vibration bearings. - The scroll and centrifugal...

Open the catalog to page 15
Fans - 16

BELT DRIVEN BOXED VENTILATORS SQUARE MOUTH TECHNICAL CHARACTERISTICS Accessories: double panels; stainless steel panels; rain protecting top; supplementary soundproof insulation; extraction connector; extraction damper. The boxed ventilators are usually supplied The boxed ventilators as standard are not supplied with aspiration opening. This must be made from the installer in the required position and dimension of the duct. All the boxed ventilators are accompanied with an instructions manual that included the declaration of conformity.

Open the catalog to page 16

All MP3 catalogs and technical brochures

  1. UV SERIES

    6 Pages

  2. FLEXIBLE DUCTS

    18 Pages

  3. TT Series

    6 Pages

  4. SA2 Series

    5 Pages

  5. SAC Series

    5 Pages

  6. XRC Series

    26 Pages

  7. XXP Series

    4 Pages

  8. XTE Series

    2 Pages

  9. AS-TN Series

    6 Pages

  10. XZO Series

    4 Pages

  11. XE Series

    2 Pages

  12. XZJ Series

    2 Pages

  13. XSR Series

    4 Pages

  14. FTR Series

    2 Pages

  15. FA Series

    2 Pages

  16. FP

    1 Pages

  17. FTF

    2 Pages

  18. XUM

    4 Pages

  19. XLA-C

    2 Pages

  20. XLF

    6 Pages

  21. diffusion

    30 Pages

  22. VAV and CAV

    82 Pages

  23. Regulation

    38 Pages

  24. Recuperators

    26 Pages

  25. Humidifiers

    6 Pages

  26. Silenciers

    20 Pages

  27. Filtering

    26 Pages

Archived catalogs

  1. silencers

    20 Pages

  2. VAV & CAV

    48 Pages

  3. diffusion

    132 Pages

  4. regulation

    20 Pages

  5. fans

    32 Pages

  6. recuperators

    6 Pages