Catalog excerpts
BASIC AIR CURTAINS OVERVIEW CHARACTERISTICS XLA-C SERIES OVERVIEW: For many applications, such as in shops with large numbers of clients coming in and out, a traditional entrance door may act as a psychological barrier to customers that shop owners would obviously like to avoid (typical examples are: large department stores, supermarkets, bars, restaurants and boutiques). One solution is automatic doors, but these create other difficulties. In fact, each time the door opens (due to someone simply passing along the pavement), the outside air comes into the shop, causing discomfort, and sometimes even illnesses for personnel and customers, as well as increasing energy consumption by air-conditioning systems. The XLA-C series of air-curtains resolve all these problems simultaneously - the customer is induced to enter, the thermo hygrometric conditions of the air remain constant and energy consumption is does not increase. In fact, consumption may drop as these barriers generate an air ring that reduces stratification (Bernoulli effect). This draws the air from the hotter areas in the room and provides a p g uniform temperature throughout. XLA-C air curtains also prevent dust, exhaust fumes, smells, and insects from entering the room. XLA-C air-curtains can even be used within the same building, to separate areas with different climate conditions. For example, heated areas from warehouses without heating. Control buttons with speed selection On/Off infra-red remote control
Open the catalog to page 1XLA-C SERIES OVERVIEW CHARACTERISTICS CHARACTERISTICS: The unit, painted RAL9016, is installed above the entrance door, using normal expansion anchors. The room air is drawn in by the fan, passed through the grille on the front and is ejected downwards. The continuous flow of air forms an invisible "curtain" that travels all the way to the floor. The fins on the air outlet can be adjusted. The unit has a 2-speed fan, with a selector switch on the unit itself and a practical remote control is also supplied. The curtian must cover at least the full width of the doorway for which it is...
Open the catalog to page 2OVERVIEW FOR DOMESTIC USE OVERVIEW CHARACTERISTICS OVERVIEW: Air-curtain are compact units that are generally installed at openings to the outdoors. They generally resolve three main requests: - Reduce entry of cold air in winter (or hot air in summer) from the outside. - Prevent dust, odours and insects entering the areas to be protected. - Can complete or replace a heating system. The XLB series of air-curtain are ideal for use in locations such as bars, hotel entrances, shops, libraries, restaurants, display areas, refrigerated stores, offices, etc. CHARACTERISTICS: The XLB series of air...
Open the catalog to page 3AIR-CURTAIN BARRIERS FOR DOMESTIC USES CONSTRUCTION DETAILS TECHNICAL DATA CONSTRUCTION DIMENSIONS Frontal view Lateral view Model code NO NO NO ELECTRICAL ELECTRICAL ELECTRICAL WATER WATER WATER * Values at air temperature of 18 °C and water temperature of 80-60 °C ** Sound pressure referred to the maximum air flow measured at 3m from the aspiration grille as per EN-ISO 3743-1 and EN-ISO 3744 *** SM= remote control - RF= radio control XLB Air-curtain barrier Without heating Water heating Electrical heating SM Remote control RF Radio control XLB
Open the catalog to page 4AIR CURTAINS FOR COMMERCIAL USE OVERVIEW CHARACTERISTICS OVERVIEW: These air-curtain are used to separate two rooms with different temperature conditions. As it descends, the air curtain separates the indoor environment, with clean air, heating, or air conditioning, from the outdoor environment. This prevents heated or cooled air from flowing out of the room and dust and insects entering the treated area. XLC air curtains are supplied with two types of intake grilles a drilled plate (standard) supplied with the air curtain or a satin-finish aluminium grille (elegance) that can be ordered...
Open the catalog to page 5AIR CURTAINS FOR COMMERCIAL USE CONSTRUCTION CONSTRUCTION: The casing is made of painted, galvanised sheet. The visible parts are painted RAL 9010 white. The upper part of the casing has four connecting points, with M8 type nuts. The fans used conform to current standards and are fitted with self-lubricating bearings, which ensure a long, maintenance-free lifespan of the unit. The motor speed can be controlled by varying the voltage between 0 and 100%. The version with the electric resistance is fitted with two safety thermostats. In standard operating mode, the thermostat keeps the air at...
Open the catalog to page 6Model code NO NO NO ELECTRIC ELECTRIC ELECTRIC WATER WATER WATER * Values for one stage / two stages activated ** Values for a temperature of 18 °C and water temperature gradient of 90/70 °C *** The noise pressure level refers to the maximum flow and is measured at 3m from the air exit opening of the unit according to EN-ISO 3743-1 ed EN-ISO 3744 norms **** For models with elctric heating, a three faze power supply, with neutral, has to be installed prior to the installation of the air curtain. ACCESSORIES XLC-SKDA XLC-SDA XLC-DS XLC-DK1 XLC-TERP XLC-V135 Pair of supports for wall fixing...
Open the catalog to page 7AIR-CURTAIN FOR CEILING INSTALLATIONS OVERVIEW CHARACTERISTICS OVERVIEW: The XLD series of air-curtains provide a modern solution to all ceiling applications. This product class provides high air flow rates to suit any need. They are easy to install in any type of ceiling and the air stream can be heated thereby reducing or even eliminating the need for any other heat source. The XLD series provide the ideal design and solution for all installations in which aesthetic appearance is important, such as in banks, hotels, restaurants, business centres, conference rooms, etc. CHARACTERISTICS:...
Open the catalog to page 9AIR-CURTAINS FOR CEILING INSTALLATIONS CONSTRUCTION DETAILS CONSTRUCTION: The particular compactness and high-level engineering of this product makes it possible to install it inside low suspended ceilings and simplify internal maintenance and/or inspection. In addition, these equipment have pre prepared holes for fixing to the ceiling. MOUNTING HOLES FOR HANGING UNDER CEILING LOW HEIGHT ALSO FOR LOW HANGED CEILINGS EASY ACCESS TO REMOVABLE ELECTRONIC BOARDS SIDE CONNECTION OF WATER HEAT EXCHANGER TWO OUTPUT TYPES B AND C FOR DOOR HEIGHTS 4 AND 7,5 M POWERFUL OUTLET AND MAINTENANCE-FREE...
Open the catalog to page 10All MP3 catalogs and technical brochures
-
UV SERIES
6 Pages
-
EXTERNAL INDUSTRIAL GRILLES
14 Pages
-
FLEXIBLE DUCTS
18 Pages
-
floor diffusers
30 Pages
-
AT-RPR Series
7 Pages
-
TT Series
6 Pages
-
SA2 Series
5 Pages
-
SAC Series
5 Pages
-
XRC Series
26 Pages
-
XXP Series
4 Pages
-
XTE Series
2 Pages
-
AS-TN Series
6 Pages
-
XZO Series
4 Pages
-
XE Series
2 Pages
-
XZJ Series
2 Pages
-
XSR Series
4 Pages
-
FTR Series
2 Pages
-
PP 30F Series
4 Pages
-
FA Series
2 Pages
-
FP
1 Pages
-
FTF
2 Pages
-
XUM
4 Pages
-
XLA-C
2 Pages
-
XLF
6 Pages
-
FIXED CONES CIRCULAR DIFFUSERS
72 Pages
-
VENTILATION GRILLES
24 Pages
-
diffusion
30 Pages
-
VAV and CAV
82 Pages
-
Regulation
38 Pages
-
Air curtain barrier
42 Pages
-
floor diffusers
22 Pages
-
Recuperators
26 Pages
-
Humidifiers
6 Pages
-
Fans
58 Pages
-
Silenciers
20 Pages
-
Filtering
26 Pages
Archived catalogs
-
silencers
20 Pages
-
VAV & CAV
48 Pages
-
diffusion
132 Pages
-
regulation
20 Pages
-
fire protection
12 Pages
-
air-curtain barriers
10 Pages
-
fans
32 Pages
-
humidification
4 Pages
-
recuperators
6 Pages