1. Catalogs
  2. Modulo parking
  3. SLANT - technical card
video corpo

SLANT - technical card

SLANT - technical card

SLANT - technical card

Product catalog summary
Overview: The MODULO SLANT is an independent parking system designed for areas with limited height, such as garages in multi-family buildings or public institutions. It features an inclined upper platform to maximize space and is suitable for various passenger cars, including limousines, station wagons, vans, and SUVs.
Specifications: The system accommodates cars up to 2000 kg in weight and 190 cm in width. The maximum gradient for driveways is 4% downslope and 10% upslope. The system requires a minimum building structure dimension and specific installation space.
Construction Requirements: The system must be anchored to a concrete floor with M12 chemical anchors. The ordering party is responsible for ventilation and fire protection systems, as well as providing a 3-phase power supply and other electrical requirements.
System Components: The system includes a supporting structure, hydraulic installation, and electrical system. The hydraulic power unit consists of a hydraulic oil tank, pump, and valves. The electrical system includes control panels and wiring.
Operation and Safety: The system operates with a 'keep pushed to actuate' principle and includes an emergency switch. Unauthorized use is prevented by a unique key. Proper car position is ensured by moveable buffers.
Maintenance and Compliance: Regular maintenance and proper ventilation are essential for longevity. The system is CE-certified and complies with relevant standards. Corrosion protection is provided as per class C3 standards.
Additional Information: Technical documents, user manuals, and maintenance agreements are available. The system is subject to acceptance by the Technical Inspection Authority.
See more

Catalog excerpts

SLANT - technical card-1

RKING SYSTEM MODULO SLANT is a system that works great in places with limited height – the upper pla orm is inclined to the lower parking space and lowered at a small angle, so as to maximize the available space. This solu on is ideal for garages with low ceilings, inter alia in mul -family buildings or public ins tu ons. It is the lightest of all MODULO Parking Systems. What is important, to be able to use it, it is 2.5 m wide, which is only as much as the standard parking space. BUILDING STRUCTURE DIMENSIONS Free space for installa on works Free space for installa on works Earth ground 530 for 480 cm long cars

 Open the catalog to page 1
SLANT - technical card-2

DIMENSIONS OF THE PIT DEPENDING ON THE MAXIMUM HEIGHT OF THE PARKED CARS In case of height values 155/290 and 170/305, station wagons entering level 1 can only do so by reverse parking. Parking at level 0 can only be done frontally.

 Open the catalog to page 2
SLANT - technical card-3

Platform working width COLUMNS OF THE BUILDING STRUCTURE Platform working width

 Open the catalog to page 3
SLANT - technical card-4

OPERATION (PARKING POSITIONS OF THE SYSTEM) Please keep in mind that you can drive onto/off the pla orm (LEVEL 1) only a er the vehicle at LEVEL 0 drives out! Pla orm entry posi on (LEVEL 1) DIMENSIONS OF DRIVEWAYS / RAMPS MAXIMUM GRADIENT OF DOWNSLOPE DRIVEWAY 4% ATTENTION! Do not exceed the specified access angle. Non-compliance with this note can result in car damage for which the manufacturer shall not be held liable. MAXIMUM GRADIENT OF UPSLOPE DRIVEWAY 10% Pla orm entry posi on (LEVEL 0

 Open the catalog to page 4
SLANT - technical card-5

CONSTRUCTION REQUIREMENTS 1. The devices have to be anchored to a concrete floor by M12 chemical (adhesive) anchors, with hole depth of ca. 12 cm. The floor should be made of at least class C20/25 concrete, minimum floor thickness – 15 cm. Installa on of all systems and structures that have to be installed in the same space as the parking system must be carried out in such a way that the parked cars are not at risk of being crushed. 2. The ordering party is responsible for designing and implemen ng a ven la on and fire protec on system in accordance with applicable regula ons. The contrac ng authority...

 Open the catalog to page 5
SLANT - technical card-6

DESCRIPTION OF THE PARKING SYSTEM STRUCTURE The MODULO SLANT parking system is a device that mul plies the number of parking spaces in a independent manner MODULO SLANT allows mul -level car parking even with lower ceiling height in comparision to other systems. The devices are powered by hydraulic power units. Device group division and the number of hydraulic power units are determined on an individual, case-to-case basis. Each device is equipped with an individual control panel that is protected against use by unauthorised persons with a unique key assigned to it. Opera on of the device follows...

 Open the catalog to page 6
SLANT - technical card-7

DESCRIPTION OF THE PARKING SYSTEM STRUCTURE AVAILABLE DOCUMENTS: User and maintenance manual, abridged user manual, declara on of conformity, structure founda on plan, maintenance offer/agreement. Pursuant to the applicable regula ons, car parking systems are subject to acceptance by the Technical Inspec on Authority. The manufacturer provides the required documenta on related to the device. The customer is under an obliga on to provide a construc on acceptance report for the floor. MAINTENANCE: In order for the device lifecycle to be as long and failure-free as possible, follow the maintenance...

 Open the catalog to page 7
SLANT - technical card-8

To download technical sheets and catalog in electronic version ar .dwg files for each of our products, please visit our website Photos from our projects are available at Find us on Facebook! Find out more about our Modulo Parking Systems on our blog: moduloparking.com/en/blog

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.