MELPRO-D

MELPRO-D
1 / 64 PagesView full catalog

MELPRO-D

Product catalog summary
Introduction
The document provides comprehensive information on Mitsubishi Electric Corporation's MELPROTM-D series, a line of numerical protection relays designed for advanced network systems and power distribution automation. It covers specifications, safety precautions, warranty details, and ordering instructions.
Specifications
The relays are designed to operate under specific environmental conditions, including temperature, humidity, and altitude. They support a range of auxiliary power and frequency deviations.
Safety Precautions
Proper handling, transportation, storage, mounting, wiring, and operation are crucial to prevent damage or malfunction. Only qualified personnel should handle the equipment to avoid risks such as electric shock.
Warranty and Guarantee
The relays come with a one-year warranty covering defects due to Mitsubishi Electric's responsibility, excluding improper use or modifications by third parties.
Ordering Instructions
Orders should specify phase current, frequency, auxiliary power supply voltage, and case type. Communication features and terminal block arrangements must also be detailed.
Key Features
  • High-Speed Digital Computation: Ensures high accuracy and stable operation.
  • Self-Diagnosis Function: Monitors inputs, power sources, and CPU for immediate failure detection.
  • Communication Network System: Enhances data acquisition and remote operation.
  • Flexibility and Extensibility: Replaceable communication cards allow adaptability.
  • Local and Remote Monitoring: Supported via RS232C port.
  • Resistance to Disturbances: Withstands electric surges, noise, and environmental factors.
Protection and Control
  • Provides protection for high voltage systems, including motor and generator protection.
  • Programmable output contacts reduce switchboard costs.
  • Measuring functions support energy management.
Maintenance and Compatibility
  • Draw-out unit mechanisms improve maintenance ease.
  • Compatible with existing relay systems.
Technical Specifications
  • Includes environmental ratings, burden, thermal withstand, and contact capacity.
  • Designed to operate within specific temperature ranges and power supply conditions.
Relay Types
Includes over-current, voltage, feeder protection, earth fault directional, biased differential, motor protection, and generator protection relays.
Operational Procedures
  • Auto reset and LED self-hold are default settings.
  • Operation results indicated via LED status and defect codes.
  • Communication options include direct and CC-Link.
Standards and Recommendations
  • Ensure grounding with resistance less than 100 ohms.
  • Use uninterruptible power supplies for auxiliary power.
  • Dedicated contacts for circuit breaker trip circuits.
  • Surge absorbers may be necessary.
Key Parameters
  • Operation time characteristics for various elements are defined.
  • Reset time characteristics and operation current settings are detailed.
Precautions
  • Consider inrush current for power supply selection.
  • Configure self-diagnosis output contacts with a time-delay timer if necessary.
  • Ensure proper connection of CTs for protection elements.
Time-Delayed Characteristics
Formulas for calculating operation time for different inverse characteristics are provided.
Connection Diagrams
Illustrates wiring concepts for phase fault and earth fault protection systems.
Voltage Relay Specifications
Details on operation voltage, time, and reset characteristics for CBV and CUB series voltage relays.
Performance Guarantees
Guarantees performance under common conditions and advises on using uninterruptible power supplies.
Power Supply and Backup
Recommends using a commercial uninterruptible power supply if power loss exceeds 2 seconds.
Inrush Current
Consider inrush current when selecting a power circuit breaker.
Trip Circuit
Use dedicated contacts for the circuit breaker trip circuit.
Self-Diagnosis Output Circuit
Configure to energize the auxiliary relay when a normal result is received.
Grounding Circuit
Follow Class D earth wiring method with grounding resistance less than 100 ohms.
CC-Link Communication Circuit
Optional communication card for CC-Link communication.
Reliability Improvement
Use a multiplex system for important facilities.
External Surge Effects
Install surge absorbers if external surges affect the relay.
Wiring Instructions
Connect EVT terminals to relay terminals as specified.
Factory Settings
Products are shipped with settings in 'LOCK' or 'minimum setting value' positions.
Testing and Safety
Use the UV test function for under-voltage element testing.
Specifications and Requirements
Details for a communication facility using a CC-Link card.
Reliability and Surge Protection
Recommends a multiplex system for critical facilities and installing surge absorbers.
Operational Lock and Polarity Considerations
Relays have a lock feature to prevent unnecessary operations.
Wiring and Configuration
Specific wiring instructions for EVT terminals and grounding.
Testing and Measurement Settings
Settings for measuring transformer ratios and EVT tertiary voltage.
Precautions and Safety
Includes handling inrush currents and input voltages.
Relay Types and Ratings
Specifications for the CGP1 Series Generator Protection Relay.
Performance and Characteristics
Guaranteed performance conditions and operation characteristics for different elements.
Front Panel Description
Includes switches and LEDs for operation and settings.
Operation and Settings
Allows for setting and forced operation through switches.
Safety Guidelines
Includes proper transportation, storage, mounting, and wiring.
Maintenance and Testing
Should be performed by qualified personnel.
Modification and Disposal
Conducted by authorized personnel to ensure warranty coverage.
Contact Information
For technical support, contact Mitsubishi Electric Corporation's Protective Relay Technical Service.
See more

Catalog excerpts

MELPRO-D-1

MITSUBISHI Numerical Protection Relay MITSUBISHI Numerical Protection Relay Mitsubishi ELectric corporation's PROtection relay for Distribution. HEAD OFFICE CAUTION TO PREVENT IT FROM THE RISK OF DAMAGE AND MAL FUNCTION, BE SURE TO READ OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS BEFORE USING. : 7-3 MARUNOUCHI 2-CHOME, CHIYODA-KU TOKYO, 100-8310, JAPAN We are waiting your technical contacts by FAX. ATTN. Protective relay technical service FAX NO. JAPAN +81-78-996-7074 Relays suitable for advanced network systems and strongly support power distribution automation.

 Open the catalog to page 1
MELPRO-D-2

Safety section This Safety section should be read before starting any work on the relay. Be sure to read the instruction manuals and other related documents prior to commencing any work on the relay in order to maintain them in a safe condition. Be sure to be familiar with the knowledge, safety information and all caution items of the I Caution means that failure to un-observe safety information, incorrect use, or improper use may endanger personnel and equipment and cause personnel injury or physical damage. Items as classified to the caution may become to occur more sever results according...

 Open the catalog to page 2
MELPRO-D-3

Request when placing order Thank you very much for your usual selecting the MITSUBISHI ELECTRIC CORPORATION products. When ordering our products described in this catalogue, please read and agree the followings before ordering as long as any special condition are not nominated in the offer document, contract document, catalogue other than this. The guarantee period of this product should be one year after delivery, unless otherwise specified by both parties. When any fault or defect is detected during the period of guarantee and such fault or defect is proved to be caused apparently at the responsibility...

 Open the catalog to page 3
MELPRO-D-4

Relays suitable for advanced communication network systems contribute to build the automated power distribution. To improve the reliability of distribution system is quite essential for the stable operation of all facilities installed in the factories and buildings. In order to realize high reliable distribution system, more functional protection relay as the core for the protection and control systems is essentially required. Through passing the age of the electric mechanical type relay and the transistor type relay, today, the main stream of protection relay has been moved to the numerical...

 Open the catalog to page 4
MELPRO-D-5

Mitsubishi Numerical type protection relay Programmable output contacts complying with requirements on the flexibility The operating output contacts can be set by combing the outputs of the protection relay element using "OR" logic, thereby simplifying sequence design. Also, it is possible to reduce the cost of switchboard as reducing wiring works. Output sequence with using "OR" logic [Schematic image of programmable output (Example: type COC4-A01)' Substantial measuring function Substantial metering function Possible to measure the steady state of the relay input values (Current, Voltage, Power,...

 Open the catalog to page 5
MELPRO-D-8

Common Technical Data VN: Rated voltage IN: Rated current

 Open the catalog to page 8
MELPRO-D-9

COC Series OVER-CURRENT RELAY Type, rating and specification A ^Please refer to the instruction manual regarding the details on this specification

 Open the catalog to page 9
MELPRO-D-10

^Please refer to the instruction manual regarding the details on this specification.

 Open the catalog to page 10
MELPRO-D-11

^1 Common condition! (l) Rating Frequency (2) Ambient temperature:20°C (3) Auxiliary power supply: Rating voltage

 Open the catalog to page 11
MELPRO-D-12

1. Guarantee against interruption of AC power supply When an uninterruptible AC power source is not available in your system for the auxiliary power supply, use the type B-Tl AC/DC converter or commercially available uninterruptible power supply (UPS). In addition, possible duration of the power supply type B-Tl AC/DC converter is confirmed as about 2 seconds in combination with one MELPRO-D series relay. Therefore, in the case that the required duration of power supply after power source loss exceeds 2 seconds, please use a suitable commercial uninterruptible power supply. When power supply...

 Open the catalog to page 12
MELPRO-D-13

Operation time and Reset time characteristics The time-delayed element have 12 kinds of operation characteristics as shown on Fig.1-1 and Fig.1-2, and 3 kinds of reset time characteristics as shown on table 1-1. ■ Inverse time-delayed characteristic for reset Following the principle of resetting an electromagnetic mechanical type induction disc, the inverse time-delayed characteristic given by the equation below is used for computing the reset time of the internal operation timer, although the output contact will be reset after a definite period of time (0.2 s). The inverse time-delayed characteristic...

 Open the catalog to page 13
MELPRO-D-14

Sample of external connection diagram power supply Self diagnosis output Programmable output (Default setting at ex-works) Fig.1 -3 COC1-A01D1 (Phase fault protection) Self diagnosis output Programmable output (Default setting at ex-works) Fig.1 -4 COC1-A01D1 (Solidly grounded neutral system, Earth fault protection) The connection diagram shows concepts of the wiring only. Therefore, please note that there will have some difference between the connection diagram and actual installation status of CT.VT and safety devices such as fuse, etc.

 Open the catalog to page 14
MELPRO-D-15

power supply Self diagnosis output Programmable output Default setting at ex-works) 'iThe terminal number A-05 is changed to A-07 and A-06 is changed to A-08 in case of COC1-A01D1 type Example: 100A grounding system power supply Self diagnosis output Earth fault • Earth fault • Programmable output Default setting at ex-works) Fig.1 -6 COC1-A02D1 (Earth fault protection) The connection diagram shows concepts of the wiring only. Therefore, please note that there will have some difference between the connection diagram and actual installation status of CT,VT and safety devices such as fuse, etc.

 Open the catalog to page 15
MELPRO-D-16

Example: 100A grounding system power supply Self diagnosis output Earth fault • Earth fault • Programmable output (Default setting at ex-works) Fig.1 -7 COC1-A02D1 (Earth fault protection) power supply Self diagnosis output Programmable output DA (Default setting at ex-works) Fig.1 -8 COC2-A01D1 (Phase fault protection) The connection diagram shows concepts of the wiring only. Therefore, please note that there will have some difference between the connection diagram and actual installation status of CT.VT and safety devices such as fuse, etc.

 Open the catalog to page 16

All MITSUBISHI ELECTRIC catalogs and technical brochures

  1. PLA-ZM-R32

    2  Pages

  2. PLA-M R32

    2  Pages

  3. PLA-SM R410A

    2  Pages

  4. PUMY-P R410A

    2  Pages

  5. MSZ-LN R32

    2  Pages

  6. I-LIFE2 SLIM

    6  Pages

  7. MSZ-AP R32

    2  Pages

Archived catalogs

  1. MSZ-HR R32

    2  Pages

  2. Hybrid VRF

    36  Pages

  3. PLATNUM

    4  Pages

  4. H2i Family

    20  Pages

  5. CITYMULTI

    96  Pages

  6. Low-Rise

    4  Pages

  7. High-Rise

    4  Pages

  8. switchgear

    16  Pages

  9. escalators

    8  Pages

  10. Matalan

    2  Pages

  11. Power Modules

    32  Pages

  12. H2iMSZ-FH

    2  Pages

  13. MFZ-KT R32

    2  Pages

  14. Office

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.