Catalog excerpts
DISTRIBUTION BOARD
Open the catalog to page 1Structure is achieved by the pursuit of high capacity. Structure assures ease of installation and wiring. Structure assures outstanding operability, maintenance performance, and safety. Accommodates units within a height of 1,800 mm, housing up to 18 units of two sets of 100 AF / 3P MCCB. Constructed to the same casing depth and configured with the same busbar scheme as the Type-B Motor Control Center, this model permits contiguous installation and direct connection of busbars of both panels. With its B wiring (standard), connection to external devices is easy through the front of the...
Open the catalog to page 2Structure External Dimensions Wiring method Indoor type Outdoor type Transparent window Transparent window Thin type Terminal blocks Terminal blocks Four φ18 installation holes per panel Basic type Wiring on the rear side of the panel to terminal blocks Wiring on the front side of the panel directly to MCCB Type: CNF-BC-652B (load cable bottom entry) 550 Side view Bottom view Horizontal busbars Note: The oblique lines indicate a space for incoming cables. Type: CNF-BC-652T (load cable top entry) Note: The oblique lines indicate a space for incoming cables. Unit space Model type Load cable...
Open the catalog to page 3Structure Busbar Unit Unit designation: BC4-12SW12SW (125 AF) Unit space Horizontal busbars (rear) Plug-in Unit base Horizontal busbars (left view) MCCB Transparent window Horizontal busbar (copper, tin plated) Rated busbar current Installation frame Installation frame Horizontal busbars Safety cover Protective cover Outside door Inside door Safety cover Transparent window Protective cover Plug-in Unit base Outside door Inside door Busbar compartment space Three-phase, three-line Three-phase, four-line Safety cover Safety cover The horizontal busbars are configured vertically in an upper...
Open the catalog to page 4Table of units Table 1 Standard feeder unit (3φ3w, 1φ2w) Unit height (mm) Table 2 Standard incoming unit (3φ3w, 1φ2w) MCCB Maximum cable size for incoming B wiring (mm2) - (screw size) Unit designation Maximum cable size for incoming B wiring (mm2)-(screw size) Ampere frame (AF) Poles Quantity Note: (1) For the units 400 AF and above, the MCCB is installed vertically at the lowest position, and a power cable is led in from the MCCB secondary side. (MCCB is installed at the highest position if the power cable is led in from the top.) (2) Units 600 AF and above require conductor connections....
Open the catalog to page 5Planning Information Installation Foundation base and installation example (indoor type) Unit: mm Configuration example 2 (with instruments on top) 3. We will provide the necessary number of foundation bolts (figure on right) when requested by the user as an option. Basic type Thin type Cross-sectional view (A-A) Frame Foundation bolt (M12) provided by customer 488 Foundation base 50×50×3.2 Buried base (not included) Bottom frame SP: Space for future additional units DSP: Space not permitting unit accommodation Incoming MCCB Foundation base 18 50×50×3.2 Buried base (not included) (2) with...
Open the catalog to page 6A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Please read the instruction manual before using the device. G-199-8-C8163-AHQ 0809 Printed in Japan (MDOC) Revised publication effective Sep. 2008. Specifications subject to change without notice.
Open the catalog to page 7All MITSUBISHI ELECTRIC catalogs and technical brochures
-
SILICON RF DEVICES_2023
12 Pages
-
HIGH FREQUENCY DEVICES_2024
4 Pages
-
MSZ-HR R32
2 Pages
-
MFZ-KT R32
2 Pages
-
PLA-ZM-R32
2 Pages
-
PLA-M R32
2 Pages
-
PLA-SM R410A
2 Pages
-
HVRF PLFY-WL-VFM-E
2 Pages
-
PUMY-P R410A
2 Pages
-
MSZ-LN R32
2 Pages
-
2020 Product Catalogue
402 Pages
-
Central Plant Solutions
24 Pages
-
I-LIFE2 SLIM
6 Pages
-
Hybrid VRF
36 Pages
-
MSZ-AP R32
2 Pages
-
OPTICAL DEVICES
8 Pages
-
SiC POWER DEVICES
12 Pages
-
Power Modules
32 Pages
-
Matalan
2 Pages
-
The Co-operative
4 Pages
-
Air Conditioning
2 Pages
-
Corporate solution
2 Pages
-
PLATNUM
4 Pages
-
M-Series Contractor Guide
47 Pages
-
H2iMSZ-FH
2 Pages
-
H2i Family
20 Pages
-
CITYMULTI
96 Pages
-
RedLINK Controllers
4 Pages
-
Commercial Controllers
2 Pages
-
Advancing HVAC
4 Pages
-
Office
4 Pages
-
Multi-Tenant Living
4 Pages
-
Low-Rise
4 Pages
-
Historic Renovation
4 Pages
-
High-Rise
4 Pages
-
switchgear
16 Pages
-
MELPRO-D
64 Pages
-
Administrative system (MELSAS-S)
10 Pages
-
escalators
8 Pages
-
PASSENGER ELEVATOR
21 Pages
-
Optical Devices Catalog
8 Pages
-
Power Devices General Catalog
60 Pages
-
Power Modules Catalog
20 Pages
Archived catalogs
-
SILICON RF DEVICES_2018
12 Pages
-
HIGH FREQUENCY DEVICES_2018
4 Pages
-
Silicon RF Devices_2013
12 Pages
-
High Frequency Devices_2013
12 Pages
-
Product Range 2008-2009
152 Pages