Catalog excerpts
AMITSUBISHI for a greener tomorrow VPR Series Vacuum Circuit Breakers Safety & Quality
Open the catalog to page 1Milffe) !L&wiJ§) @if ami iaii§% AMIemdj TrbiDQiiignj y§ej @jfj tjt© Ha tesfr Tie.c h n olo.gteS) Vac u u mi <§i§ii BreakerrS] E^silepeJ 1M tjnej pulyjej wjithi in ha need I Bnv/iiionmental llgassesj art Maintenance; IfeajMife^ • Incorporates Mitsubishi Electric vacuum interrupter technology, realizing a more compact vacuum interrupter (VI) 16% smaller than in the previous type* and high reliability (class E2). Self-cooling vacuum circuit breakers (VCBs) that do not require a fan to be mounted on the panel. Available in a wide range, from rated current of 600 to 3,150A. • Compliant with IEC...
Open the catalog to page 2Cutting-edge Technologies Using 3D CAD and CAE VCB Structure to Ensure the Utmost Levels of Reliability and Safety Operating Mechanism Through use of thermal fluid analysis, we have realized efficient release of heat to the cylinder-shaped insulation frame covering the VCB main circuit part, enabling a self-cooling mechanism up to a rated current of 3,150A. Greater performance reliability and extension of the lubrication cycle from three to six years through measures for the operating mechanism such as minimizing the number of parts, reducing the number of moving parts, adopting oilless...
Open the catalog to page 3Type Selection M2, E2, and C2 Classes Described in the Specifications (IEC62271-100) Classification as for Mechanical Endurance ( M1 and M2 ) The IEC standards broadly divide the mechanical operating test into classes M1 and M2. At the control voltages shown in Table 1, class M1 requires the rated operation sequence to be performed 2,000 times in total while class M2 requires the rated operation sequence to be performed 10,000 times in total. At five times the actuating cycle of class M1, class M2 represents a highly reliable operation class. Table 1 M1 and M2 operating sequence. Control...
Open the catalog to page 4Ratings Table 3 List of Ratings (JEC / IEC Standards). Type Closing operating mechanism Table 4 List of Ratings (JEC / IEC Standards). Closing operating mechanism Motor-spring charged mechanism Motor-spring charged mechanism JEC-2300-2010 / IEC 62271-100-2012 Rated normal current (A) Rated frequency (Hz) Rated short-circuit breaking current (kA) Rated short-circuit breaking current (kA) Rated making current (kA) Rated short-time withstand current (kA) Rated making current (kA) Rated short-time withstand current (kA) Rated opening time (s) Power frequency (JEC/IEC) Lightning impulse(JEC/IEC)...
Open the catalog to page 5Description and Structure VCB Configuration Mounting Frame Configuration Manual charging handle aperture Primary junction Manual close button (with button cover) Manual trip button Closing spring indicator Secondary junction Front view of mounting frame (with earthing switch) Rear view of mounting frame (with earthing switch) Closing spring charged indication switch (page 21) Additional auxiliary switch (page 22) Padlock device for close and trip button (page 22) Short-circuit capacity earthing (page 24) Mechanical locking device (page 21) Additional shunt tripping coil (page 22) Position...
Open the catalog to page 6I600A/630A, 1,200A/1,250A Rating: External Dimensions (Circuit Breaker) Fixed (type-L) Manual close Withdrawable with door closed Code B: with interlock handle aperture Withdrawable with door open Code B: with interlock without interlock Draw-out \ Maximum handle aperture \ displacement Interlock lever Shutter guide \ Additional auxiliary switch (option) 600A/630A, 1,200A/1,250A Rating: External Dimensions (Mounting Frame) this distance keep 126mm or more, or cover busbars with insulation cover. Details of main-circuit terminal Details of main-circuit terminal that this distance keep cover...
Open the catalog to page 71,600A, 2,000A Rating: External Dimensions (Circuit Breaker) Fixed (type-L) Closing spring charge indicator Withdrawable with door closed Manual charging handle aperture Withdrawable with door open Shutter guide Additional auxiliary switch (option) ■ 1,600A, 2,000A Rating: External Dimensions (Mounting Frame) this distance keep 1 26mm or more, or cover busbars with insulation cover. Details of main-circuit terminal Details of main-circuit terminal that this distance keep cover busbars with insulation cover.
Open the catalog to page 8■ 2,500A, 3,000A/3,150A Rating: External Dimensions (Circuit Breaker) Withdrawable with door closed (type-M) Withdrawable with door open (types C, D and G) 2,500A, 3,000A/3,150A Rating: External Dimensions (Mounting Frame) Air clearance for ventilation (more than 400cm; Details of main-circuit terminal that this distance keep cover busbars with insulation cover. edge busbars. Details of main-circuit terminal that this distance keep cover busbars with insulation cover.
Open the catalog to page 9Withdrawable: Standard Connection Diagram (Code A) Note: There is no LSO in a fixed (type-L) This device is not supplied with the VCB; please order separately. The shunt tripping coil (STC) is for DC only; for AC operation, use a capacitor tripping device for conversion to DC. When the auxiliary switch has micro current specifications, are contacts for micro current. the micro current specification auxiliary switch, the tripping coil disconnection monitoring the capacitor tripping device and LS3. In the above wiring diagram; Circuit breaker: Opened state Closing spring : Discharged state...
Open the catalog to page 10Accessories Secondary Connector Lifting Adapter The panel side lead wires connect the input voltage and VCB unit. They are inserted in the control plug section of the VCB. A lifting adapter used to lift the VCB. Please refer to the directions for use in the instruction manual. Number of accessories: 1 per unit Number of accessories: 1 per 1-5 VCBs (min. 1) Code B Manual Charging Handle This handle enables the closed spring to be charged manually by inserting the handle in the front manual charging handle aperture and rotating clockwise for approximately 15 rotations. Shipping Clamp Number...
Open the catalog to page 11iCIosing Spring Charged Indication Switch Used for charging/discharging output of closing springs. Table 5 Contact ratings. 1: Please refer to the standard connection diagram for 2: Fig. 38 shows a closed spring in a dischrged state. 3: LS3 (limit switch for the spring charge indicator) iTripping Coil Disconnection Monitoring This function monitors disconnection of the tripping coil and control connector based on output from the input terminal. The disconnection monitoring current is 30mA or below. ■ Additional Auxiliary Switch (Additional 5a5b) The switch makes it possible to add 5a5b to a...
Open the catalog to page 12All MITSUBISHI ELECTRIC catalogs and technical brochures
-
SILICON RF DEVICES_2023
12 Pages
-
HIGH FREQUENCY DEVICES_2024
4 Pages
-
MSZ-HR R32
2 Pages
-
MFZ-KT R32
2 Pages
-
PLA-ZM-R32
2 Pages
-
PLA-M R32
2 Pages
-
PLA-SM R410A
2 Pages
-
HVRF PLFY-WL-VFM-E
2 Pages
-
PUMY-P R410A
2 Pages
-
MSZ-LN R32
2 Pages
-
2020 Product Catalogue
402 Pages
-
Central Plant Solutions
24 Pages
-
I-LIFE2 SLIM
6 Pages
-
Hybrid VRF
36 Pages
-
MSZ-AP R32
2 Pages
-
OPTICAL DEVICES
8 Pages
-
SiC POWER DEVICES
12 Pages
-
Power Modules
32 Pages
-
Matalan
2 Pages
-
The Co-operative
4 Pages
-
Air Conditioning
2 Pages
-
Corporate solution
2 Pages
-
PLATNUM
4 Pages
-
M-Series Contractor Guide
47 Pages
-
H2iMSZ-FH
2 Pages
-
H2i Family
20 Pages
-
CITYMULTI
96 Pages
-
RedLINK Controllers
4 Pages
-
Commercial Controllers
2 Pages
-
Advancing HVAC
4 Pages
-
Office
4 Pages
-
Multi-Tenant Living
4 Pages
-
Low-Rise
4 Pages
-
Historic Renovation
4 Pages
-
High-Rise
4 Pages
-
switchgear
16 Pages
-
MELPRO-D
64 Pages
-
Administrative system (MELSAS-S)
10 Pages
-
escalators
8 Pages
-
PASSENGER ELEVATOR
21 Pages
-
Optical Devices Catalog
8 Pages
-
Power Devices General Catalog
60 Pages
-
Power Modules Catalog
20 Pages
Archived catalogs
-
SILICON RF DEVICES_2018
12 Pages
-
HIGH FREQUENCY DEVICES_2018
4 Pages
-
Silicon RF Devices_2013
12 Pages
-
High Frequency Devices_2013
12 Pages
-
Product Range 2008-2009
152 Pages