Overview: This document outlines the specifications and operational guidelines for the Mitsubishi Freight Elevator Series GFM-T, aimed at improving goods-handling efficiency.
Specifications:
  • Capacity: 750kg to 6000kg.
  • Speed: 30m/min to 60m/min.
  • Door Types: 2-panel side opening (2S), 3-panel side opening (3S), 4-panel center opening (2CO), 2-panel upward opening (2U), 3-panel upward opening (3U).
  • Machine Room: Positioned above the hoistway.
Operational Systems:
  • Single Automatic for Freight (1BF): Standard operation for individual calls.
  • Selective Collective (2BC): Optional sequential call response.
Door Systems:
  • Horizontal Sliding Doors: Fast operation, aligns entrance and car width.
  • Vertical Sliding Doors: Not compliant with EN-81-1 or GB code.
Safety Features:
  • Safety Door Edge (SDE): Detects contact during door closing.
  • Ultrasonic Door Sensor (USDS): Scans area near open doors.
  • Overload Holding Stops (OLH): Indicates car overload.
Additional Features:
  • Emergency Car Lighting (ECL-C): Provides lighting during power outages.
  • Earthquake Emergency Return (EER): Stops cars at nearest floor during seismic events.
  • Fire Emergency Return (FER): Returns cars to evacuation floor during fires.
Layout and Dimensions: Includes detailed drawings and dimensions for various door types, with compliance and installation notes.
Specifications and Dimensions: Details dimensions for elevator door types, specifying entrance width, wall thickness, jamb depth, and entrance height. Some door types are not applicable for EN-81-1 or GB code.
Electrical Installation: Outlines requirements for the machine room, including transformers, ground wire, lighting power supply, and ventilation. Voltage fluctuation should be within +5% to -10%, with a voltage imbalance factor of 5%.
Power Supply and Ventilation: Requires a power supply with sufficient capacity. Lighting should be on a separate circuit. A ventilating fan and window are necessary to maintain the machine room temperature below 40°C.
Inter Communication System: Essential for emergency communication, with the master station's position determined early in building design.
Lighting and Inspection Power Outlets: Adequate lighting is required for maintenance, with inspection power outlets in the machine room and pit.
Power Feeder Data: Provides detailed data on capacity, speed, motor power, and current ratings for different elevator specifications.
Work Not Included in Elevator Contract: Excludes tasks like building the machine room, architectural finishing, and electrical wiring, which are the responsibility of the building owner or contractor.
Elevator Site Requirements: Machine room and hoistway must be below 40°C, with humidity below 90% monthly and 95% daily. Areas should be finished to prevent concrete dust, and voltage fluctuation should be within specified limits.
Ordering Information: Orders should include unit details, speed, capacity, stops, travel, operation system, design, and power source specifications.
Note: Specifications may change without notice, and local laws may affect work responsibilities.
See more

Catalog excerpts

GFM-T-1

Freight Elevator Series GFM-T

 Open the catalog to page 1
GFM-T-2

Mitsubishi Freight Elevators Can Improve Your Goods-Handling Ability Basic Specifications The following dimension is shown in Japan code. Entrance (mm) Car interior (mm) Loading equipment and scope of application Door type Speed (m/min.) Elevator Selection 1. Rated capacity and car size What is the maximum weight or size of goods to be transported at one time? Is a forklift used to load and unload goods? Check shaft size and loading area Traction type Directly over the hoistway Machine room location Responds to individual calls. It cannot General operation system for typical register new calls...

 Open the catalog to page 2
GFM-T-3

Operation System Signal fixtures such as Car operating panel and Hall position indicator, etc., are shown according to operation system. The applications vary based on the model, so please confirm when ordering. Single automatic for freight (1BF) : Standard Selective collective (2BC) : Optional Finishes and Designs 2-panel side opening Door frame Entrance Doors Entrance Sill Hall buttons Car Ceiling Car Walls Car Doors Flooring Car Sill Lighting Car wall protectors Narrow Jamb with Painted steel sheet Painted steel sheet Extruded hard aluminum (Capacity of 2000kg or less) Steel plate with black...

 Open the catalog to page 3
GFM-T-4

Descriptions Painted steel sheet Walls and Transom Panel Stainless steel hairline Panel Doors (Horizontal Sliding Doors) Painted steel sheet Stainless steel hairline Steel Mesh Doors (Vertical Sliding Doors) Expanded metal with painted finish Painted steel sheet Fluorescent light fixtures Entrance Columns (Only Horizontal Sliding Doors) Stainless steel hairline Stainless steel hairline Checkered steel plate with black paint Capacity of 2000kg or less Extruded hard aluminum Steel plate with black paint Same unit as car flooring Vertical Sliding Doors Painted steel sheet Narrow Jamb Stainless steel...

 Open the catalog to page 4
GFM-T-5

Layout Drawings and Dimensions for One Gate (1D1G) For JIS Code The following dimension is shown in Japan code. Type Capacity Speed Motor (kg) (m/min.) (kW)*1 Machine room (mm) AM✕BM Hoistway Plan for 2-panel side opening door (2S) Hoistway Plan for 3-panel side opening door (3S) Hoistway Plan for 2-panel upward opening door (2U) Hoistway Section 2-panel upward 3-panel side opening door opening door 2-panel side opening door Max. Travel 30m Entrance height HH Ventilation hole (by owner) Reaction loads (kN)*2 Machine room Control panel Access door W1200XH2000 Min. floor Overhead OH height (mm)...

 Open the catalog to page 5
GFM-T-6

Layout Drawings and Dimensions for Two Gates (1D2G & 2D2G) For JIS Code The following dimension is shown in Japan code. Type Capacity Speed Motor (kg) (m/min.) (kW)*1 Machine room (mm) AM✕BM Hoistway Plan for 2-panel side opening door (2S) Hoistway Plan for 3-panel side opening door (3S) Hoistway Plan for 2-panel upward opening door (2U) Min. clear machine room height Hoistway Section Cinder concrete finish (by owner) Access door W1200 H2000 Ventilation hole (by owner) 2-panel upward opening door 3-panel side opening door Machine room *1: Since required motor power varies according to the specifications,...

 Open the catalog to page 6
GFM-T-7

Entrance Layouts Wall thickness 28 Finish 137 4-panel center opening door (2CO) 2-panel side opening door (2S) 2-panel upward opening door (2U) 3-panel side opening door (3S) Sill width Sill width 3-panel upward opening door (3U) Wall thickness 31 Finish 174 *1: Since dimensions for vertical sliding doors vary according to the entrance width, entrance height and floor height, please consult our sales agency for details. 200 *1

 Open the catalog to page 7
GFM-T-8

Electrical Installation Important Information on Elevator Planning ELEVATOR MACHINE ROOM Vent. fan Celling-lighting equipment Control panel Traction motor ELECTRICAL ROOM NF breaker *2 Traction-machinery power supply Ground wire *1 Receiving box Ventilation window Power outlet Lighting power supply Receiving box Inter Communication System *1: The minimum size of ground wire is determined according to the ampere rating of the NF breaker installed at the power source side. Supervisor's room *2: The current rating of the power-source NF breaker should be of one level larger than that of the receiving-box...

 Open the catalog to page 8
GFM-T-9

INTERNATIONAL NETWORK Inquiries and orders should be directed to the following offices. Some products may not be available for sale in some countries. Country/Area Company/Telephone/Fax/Address Country/Area Company/Telephone/Fax/Address Hong Kong Mitsubishi Elevator Hong Kong Co., Ltd. 7F., 321 Java Road, North Point, Hong Kong Shanghai Mitsubishi Elevator Co., Ltd. 811 Jiang Chuan Road, Minhang, Shanghai 200245, P.R.C. Mitsubishi Elevator Hong Kong Co., Ltd. 7F., 321 Java Road, North Point, Hong Kong Taiwan Mitsubishi Elevator Co., Ltd. Chung-Ling Building, No. 363, Sec. 2, Fu-Hsing S. Rd.,...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.