video corpo

DIAMOND TRAC
1 /15Pages

DIAMOND TRAC

DIAMOND TRAC
1 /15Pages

Catalog excerpts

DIAMOND TRAC-1

PASSENGER ELEVATORS (MACHINE-ROOM-LESS SYSTEM)

 Open the catalog to page 1
DIAMOND TRAC-2

Based on our policy, "Quality in Motion", we provide elevators and escalators that will satisfy our customers with high levels of comfort, efficiency, ecology and safety. Mitsubishi Electric elevators, escalators and building management systems are always evolving, helping achieve our goal of being the No.l brand in quality. In order to satisfy customers in all aspects of comfort, efficiency and safety while realizing a sustainable society, quality must be of the highest level in all products and business activities, while priority is place on consideration for the environment. As the times change,...

 Open the catalog to page 2
DIAMOND TRAC-3

More technological advances, such as the high-accumulation LSI and low-noise PWM inverter, enable the VVVF inverter to deliver smooth, high-precision control of the traction machine. In addition, the IU (Inverter Unit) acts as a high-efficiency power supply circuit for the motor drive and, along with the PM motor, delivers greater energy savings. The result is a more efficient drive control. Power supply Regenerative operation Mitsubishi Electric elevator quality is constantly evolving. Our machine-room-less elevator provides technological advances that deliver a world-class ride in terms of...

 Open the catalog to page 3
DIAMOND TRAC-4

Architects, builders, and even interior designers will appreciate the new design freedom that comes with the machine-room-less system. A machine room is no longer needed, as all machineries successfully fit into the hoistway, except the control panel, which can be placed within a 98-foot, 5-inch radius of the traction machine. Also, the load stress of our conventional elevator with a machine room applies on the building structure, whereas the guide rails of DIAMOND TRAC support as much as 75 percent of the stress, for building friendliness. Mitsubishi Electric has succeeded in miniaturizing key...

 Open the catalog to page 4
DIAMOND TRAC-5

HALL SIGNAL FIXTURES Hall Lanterns Hall Buttons Stainless steel hairline Clear acrylic, yellow-orange when UP side is illuminated, and red when DOWN side is illuminated Plastic round-type micro stroke click button (standard) Stainless steel round-type micro stroke click button (option) Stainless steel hairline Stainless steel hairline Display panel Smoky gray plastic, matt surface Direction and position indicator Digital LED dot display, orange when illuminated Clear acrylic with frosted finish, yellow-orange when UP side is illuminated, and red when DOWN side is illuminated Round-type micro...

 Open the catalog to page 5
DIAMOND TRAC-6

FUNCTIONS Feature Standard Features DOOR OPERATION FEATURES If the elevator doors do not open fully at a destination floor, the doors close and the car automatically moves to the next or nearest floor, where the doors will open. A buzzer sounds to alert the passengers that the car is overloaded; the doors remain open and the car does not leave that floor until enough passengers exit the car. If a car has stopped between floors due to an equipment malfunction, the controller checks the cause, and if it is considered safe to move the car, the car will move to the nearest floor at a low speed and...

 Open the catalog to page 6
DIAMOND TRAC-7

FUNCTIONS Description Optional Features GROUP CONTROL FEATURES To enhance security, service to desired floors can be set to disable using the car operating panel. This function is automatically deactivated during emergency operations. With a key switch on the supervisory panel, etc., a car can be called to a specified floor after responding to all car calls, and then automatically be taken out of service. Secret Call Service (SCS-B) To enhance security, car calls for desired floors can be registered only by entering secret codes using the car buttons on the car operating panel. This function...

 Open the catalog to page 7
DIAMOND TRAC-8

BASIC SPECIFICATIONS CAPACITY: 2000lbs ~ 4000lbs Capacity, Rated Speed, Door Type, Car Inside & Hoistway Dimensions*1 Front & Rear Car inside clear dimensions Width (ft./in.) Depth (ft./in.) Entrance width JJ (ft./in.) 3'-0" Minimum hoistway dimensions*3 AH: Width (ft./in.)*4 7'-6" Maximum number of stops Front Front & Rear Front OH*6 (ft./in.) Canopy height Canopy height 8'-0" 9'-6" OH*6 (ft./in.) Canopy height Canopy height 8'-0" 9'-6" Front & Rear Front Rated speed Opening Front Front & Rear Canopy height Canopy height 8'-0" 9'-6" 15'-3" Notes *1. The contents of these tables are standard...

 Open the catalog to page 8
DIAMOND TRAC-9

BASIC LAYOUTS CAPACITY: 2000lbs ~ 4000lbs Front Opening Hoistway Plan (example) Hoistway Section Car hitch beam: Refer to page 21. Front & Rear Opening Hoistway Plan Hoistway Section Car hitch beam: Refer to page 21. Hoisting beams (by others) Hoisting beams (by others) Car inside clear (Depth) BH AH AU Design REAR SIDE Shown for Single-Slide door CONTROL PANEL Car inside clear (Width) FRONT SIDE Shown for Center-Open doors Car inside clear (Width) JJ Car inside clear (Width) Car inside clear (Width) Shown for Center-Open doors JJ Car inside clear (Width) Access door width 3'-0" Pit depth PD...

 Open the catalog to page 9
DIAMOND TRAC-10

BASIC SPECIFICATIONS CAPACITY: 4000lbs ~ 5000lbs Capacity, Rated Speed, Door Type, Car Inside & Hoistway Dimensions*1 Front & Rear Car inside clear dimensions Width (ft./in.) 5'-8" Depth (ft./in.) Entrance width JJ (ft./in.) Minimum hoistway dimensions*3 AH: Width (ft./in.)*4,7 Maximum number of stops Maximum travel (ft.) Minimum floor height (ft.) For travel greater than shown above, please consult your local sales office or [email protected]. Rated speed Front / Front & Rear Capacity Entrance width AH dimension (ft./in.) (lbs) JJ (ft./in.) 2 Car 3 Car 4000 4500 5000 5000 Rated speed Service...

 Open the catalog to page 10
DIAMOND TRAC-11

BASIC LAYOUTS CAPACITY: 4000lbs ~ 5000lbs Front Opening Hoistway Plan (example) Hoistway Section Car hitch beam : Refer to page 22. Hoisting beams (by others) Front & Rear Opening Hoistway Plan (example) Hoistway Section Car hitch beam : Refer to page 22. REAR SIDE Hoisting beams (by others) Car inside clear (Width) Access door width 3'-0" REAR SIDE Shown for 2-Speed side-open doors FRONT SIDE Car inside clear (Width) Access door width 3'-0" Disconnect switch (by others) Cab height 8'-0" (STD) Car inside clear (Depth) Disconnect switch (by others) Car inside clear (Depth) FRONT SIDE Disconnect...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.