MINIB 2009
88Pages

{{requestButtons}}

Catalog excerpts

MINIB 2009 - 19

without fan COIL - PW COIL - PW CHARACTERISTICS X high heat output convector without fan CD r» o oo o CM (M o (M + ■S r» co r» co o co o CM + O 00 r» o oo o CM CM o C\l 05 DIMENSIONS total width construction height length 380 mm 125 mm 900 - 3000 mm UOHu C Designed to provide medium heat output where construction width is not a limiting factor. TEMPERATURE EQUATION where: m=1,4212 t. temperature exponent mean water temperature [°C] mean air temperature [°C] nominal heat transfer rate for difference of temperatures tW - tA = 50 °C [W] the coefficient of water flow rate, u:=1 mass flow rate...

Open the catalog to page 19
MINIB 2009 - 28

Forced Convection (with fan) COIL -T80 CHARACTERISTICS X for heating dry interiors X very low MINIB convector (only 80 mm in the floor) X supplied with any aluminium or wooden grille DIMENSIONS total width 243 mm construction height 80 mm length L 900 - 3000 mm USAGE Designed for individual use in dry interiors with higher heating demands and low construction height requirements (up to 80 mm) where the deeper COIL-KT units cannot be used. CROSS SECTION OF COIL-T80 o TEMPERATURE EQUATION <§) CD O N O co where: m=1.09663 tW temperature exponent mean water temperature [°C] mean air temperature...

Open the catalog to page 28
MINIB 2009 - 30

COIL - KT0 Forced Convection (with fan) COIL - KT0 CHARACTERISTICS X the narrowest available convector. total width 106 mm X for heating dry interiors DIMENSIONS total width construction height length L 106 mm 125 mm 900 - 3000 mm USAGE The convector COIL - KT0 is MINIB's narrowest available floor convector. It is a fast-responding heater from the lower heat output series of MINIB convectors with the 12V fan. Despite the extreme-ly narrow design, the convector can achieve heat outputs of approx. 450 W/m of length. Use is re-commended in cases where the extremely narrow profile of the floor...

Open the catalog to page 30
MINIB 2009 - 40

COIL-MO Forced Convection (with fan) COIL - MO CHARACTERISTICS X powerf ul MIN IB con vector X COIL - MO: heating of any interior (in winter) and in te r i o r cooli ng (i n summer) wi t h t h e possibil i ty of moist ure cond ensat i o n in the t rench X COIL - M 0 : h eati n g of sw i mmi ng pool s DIMENSIONS total wid t h 303 mm con st r uct ion h ei gh t 1 30 mm I eng t h L 900 - 3000 mm USAGE C o n vector CO I L - M O i s used as a fast react i n g h eat in g e I em ent s ui ta bl e for h eat i n g of in te r i ors with h i gh h eat loads . Convector CO IL - M O i s a I so s ui tab I e...

Open the catalog to page 40
MINIB 2009 - 42

COIL - HC Forced Convection (with fan) COIL - HC CHARACTERISTICS x very effective convector for heating and cooling X 2-tube connection X air is blown tangentially into the interior X cooling output approximately 1000 W for the 2 metre long convector DIMENSIONS total width construction height length L 243 mm 125 mm 900 - 3000 mm USAGE COIL - HC is a MINIB floor convector special-ly designed for both heating and cooling of the space. The convector has the 2-tube connection and common cooling and heating circuit. The air is tangentially blown across the floor of the room to a distance of 3 to...

Open the catalog to page 42
MINIB 2009 - 76

CONTROL D Control D (dry environment, automatic step control, programmable thermostat) Control D is automatic step control suitable for dry and wet environment. This control can be also used for heating mode in winter and cooling in summer. CYKY 3x1,5 (brown, black, yellow-green) o sz o 1 MINIB TT1-DC MINIB TH-0108 contactless c E Control panel D PE ծ\ 0V 5^ Lo Mi Com Hi 24V 2'3r , 2'2r OP MAX7A <§) CD O 'b N O co EMK1 CYKY 3x1,5 (black, black, brown) EMK2 EMKn CO CL O O CM CO ■sr ^cfl o > o >co >CD CO o co 93 2 Control D can control cooling of the space if sufficiently cool water is...

Open the catalog to page 76
MINIB 2009 - 77

CONTROL E1 Control E1(wet environment, automatic step control, programmable thermostat) Automatic control for convectors used in wet environment. CD r» o oo o CM CM O CM + ■S r» co r» co o co o CM + CD 00 o 00 o CM CM o CM 05 CYKY 3x1,5 (brown, black, yellow-green) K1.1, -cr - o szo 1 (fi Switchboard o MINIB TH-0108 contactless OP Control panel E.1 i MINIB TT3-E1 / (TT5-E1) 3.2R 3.1 C 2.3 c 2.1 c ~12Va ~12Vb Cable UTP5 with terminals RJ45 CYKY 2x1,5 (black, brown) N o TT3-E1 max. 20 A TT5-E1 max. 27 A co ce cl o o CM co a> ^cC o > o >co co CD EMK1 EMK2 Connecting terminals FC 1 Connecting...

Open the catalog to page 77
MINIB 2009 - 78

CONTROL E Control E (dry and wet environment, automatic control, programmable thermostat) Fully automatic control of convectors with continuous speed control. The most advanced MINIB controller. CYKY 3x1,5 (brown, black, yellow-green) K1.1, -ori- ro o .Q .c o 1 (fi -1551- MINIB TT1-DC MINIB TH-0108 contactless Switchboard o control panel E 51 0V S Lo Mi txH-i Com 5S-I R OP 11^ 2.1 ˕PE Hi 24V MAX7A <§) CD O N O co EMK1 CYKY 3x1,5 (black, black, brown) EMK2 FC 2 EMKn co cl o o CM CD ■sT ^cC O > o >co >CD CO CD co 93 2 CD lu FC 1 FC n Connecting terminais Connecting terminais Connecting...

Open the catalog to page 78

All MINIB catalogs and technical brochures

  1. NCA

    2 Pages

  2. NCA 4P

    2 Pages

  3. SKB

    2 Pages

  4. SPB

    2 Pages

  5. NKB

    2 Pages

  6. NPB

    2 Pages

  7. NEWS

    28 Pages

  8. CONTTROLS

    3 Pages

  9. NEWS MINIB

    3 Pages

  10. BEST OF MINIB

    11 Pages

  11. CATALOGUE MINIB

    108 Pages

Archived catalogs

  1. COIL - SW250

    1 Pages

  2. COIL- SP2/4

    1 Pages

  3. COIL – SU2

    1 Pages

  4. COIL – SU1

    1 Pages

  5. COIL – NU2

    1 Pages

  6. COIL – NU1

    1 Pages

  7. COIL – DP

    1 Pages

  8. COIL – LP

    1 Pages

  9. COIL – SK2

    2 Pages

  10. COIL – SK1

    2 Pages

  11. COIL – NK1

    2 Pages

  12. COIL – KP

    1 Pages

  13. COIL – TE

    1 Pages

  14. COIL – MT2

    2 Pages

  15. COIL – KT3

    2 Pages

  16. COIL – HCM

    2 Pages

  17. COIL – HC

    2 Pages

  18. COIL – M0

    2 Pages

  19. COIL – MT

    2 Pages

  20. COIL – KT2

    2 Pages

  21. COIL – KT1

    2 Pages

  22. COIL – KTO

    2 Pages

  23. COIL – T80

    2 Pages

  24. COIL-T50

    2 Pages

  25. COIL – KT

    2 Pages

  26. COIL – KO

    2 Pages

  27. COIL – PW

    1 Pages

  28. COIL – PO

    1 Pages

  29. COIL – PT

    1 Pages

  30. COIL – P

    1 Pages