1. Catalogs
  2. MINIB
  3. MINIB 2009
video corpo

MINIB 2009

MINIB 2009
1 / 88 PagesView full catalog

MINIB 2009

Product catalog summary
Overview: The document provides comprehensive technical specifications and performance data for various convector models manufactured by MINIB, a company based in Prague, Czech Republic. These convectors are designed for heating and cooling applications in both dry and wet environments, suitable for residential and commercial spaces.
Specifications:
  • COIL-HC and COIL-HC4pipe: Designed for heating and cooling with dimensions ranging from 900 to 3000 mm in length. The COIL-HC4pipe offers separate circuits for heating and cooling.
  • COIL-HCM and COIL-HCM4pipe: Feature high cooling outputs and are suitable for intensive heating and cooling applications.
  • COIL-KT3, COIL-MT2, COIL-TE, COIL-SK, COIL-KP: Each model has specific characteristics, dimensions, and usage scenarios, such as fast-reacting heating, universal convector with automatic airflow, and electrical heating for dry interiors.
Performance Data: The document includes tables detailing heat transfer rates for various lengths and temperatures, cooling outputs, and acoustic characteristics. It provides equations for calculating heat transfer rates based on mean air and water temperatures.
Usage Recommendations: Convectors are recommended for spaces with windows to prevent condensation and are suitable for both residential and commercial environments. Specific models are designed for skirting, kick space mounting, or installation into window sills.
Control Systems: MINIB offers several control systems tailored for different environments, including basic single-speed controllers, programmable thermostats, and fully automatic controls.
Installation Guidelines: Convectors should be installed horizontally with proper connection to piping and wiring. Specific instructions are provided for embedding in concrete or installing in wooden floors.
Standards and Recommendations: Installation must comply with safety standards, especially in wet areas. Only qualified personnel should perform installations, and all drainage lines in wet areas should be non-conducting.
Warranty: A two-year warranty is provided on convector parts, with a ten-year warranty on the heat exchanger and rust-through protection.
Contact Information: MINIB s.r.o., Střešovická 49, 162 00 Praha 6, Czech Republic. Tel: +420 220 180 780, Email: [email protected], Website: www.minib.cz
See more

Catalog excerpts

MINIB 2009-9

cross section of convectors

 Open the catalog to page 9
MINIB 2009-19

without fan COIL - PW COIL - PW CHARACTERISTICS X high heat output convector without fan CD r» o oo o CM (M o (M + ■S r» co r» co o co o CM + O 00 r» o oo o CM CM o C\l 05 DIMENSIONS total width construction height length 380 mm 125 mm 900 - 3000 mm UOHu C Designed to provide medium heat output where construction width is not a limiting factor. TEMPERATURE EQUATION where: m=1,4212 t. temperature exponent mean water temperature [°C] mean air temperature [°C] nominal heat transfer rate for difference of temperatures tW - tA = 50 °C [W] the coefficient of water flow rate, u:=1 mass flow rate of...

 Open the catalog to page 19
MINIB 2009-28

Forced Convection (with fan) COIL -T80 CHARACTERISTICS X for heating dry interiors X very low MINIB convector (only 80 mm in the floor) X supplied with any aluminium or wooden grille DIMENSIONS total width 243 mm construction height 80 mm length L 900 - 3000 mm USAGE Designed for individual use in dry interiors with higher heating demands and low construction height requirements (up to 80 mm) where the deeper COIL-KT units cannot be used. CROSS SECTION OF COIL-T80 o TEMPERATURE EQUATION <§) CD O N O co where: m=1.09663 tW temperature exponent mean water temperature [°C] mean air temperature [°C]...

 Open the catalog to page 28
MINIB 2009-30

COIL - KT0 Forced Convection (with fan) COIL - KT0 CHARACTERISTICS X the narrowest available convector. total width 106 mm X for heating dry interiors DIMENSIONS total width construction height length L 106 mm 125 mm 900 - 3000 mm USAGE The convector COIL - KT0 is MINIB's narrowest available floor convector. It is a fast-responding heater from the lower heat output series of MINIB convectors with the 12V fan. Despite the extreme-ly narrow design, the convector can achieve heat outputs of approx. 450 W/m of length. Use is re-commended in cases where the extremely narrow profile of the floor convector...

 Open the catalog to page 30
MINIB 2009-40

COIL-MO Forced Convection (with fan) COIL - MO CHARACTERISTICS X powerf ul MIN IB con vector X COIL - MO: heating of any interior (in winter) and in te r i o r cooli ng (i n summer) wi t h t h e possibil i ty of moist ure cond ensat i o n in the t rench X COIL - M 0 : h eati n g of sw i mmi ng pool s DIMENSIONS total wid t h 303 mm con st r uct ion h ei gh t 1 30 mm I eng t h L 900 - 3000 mm USAGE C o n vector CO I L - M O i s used as a fast react i n g h eat in g e I em ent s ui ta bl e for h eat i n g of in te r i ors with h i gh h eat loads . Convector CO IL - M O i s a I so s ui tab I e for...

 Open the catalog to page 40
MINIB 2009-42

COIL - HC Forced Convection (with fan) COIL - HC CHARACTERISTICS x very effective convector for heating and cooling X 2-tube connection X air is blown tangentially into the interior X cooling output approximately 1000 W for the 2 metre long convector DIMENSIONS total width construction height length L 243 mm 125 mm 900 - 3000 mm USAGE COIL - HC is a MINIB floor convector special-ly designed for both heating and cooling of the space. The convector has the 2-tube connection and common cooling and heating circuit. The air is tangentially blown across the floor of the room to a distance of 3 to 4...

 Open the catalog to page 42
MINIB 2009-76

CONTROL D Control D (dry environment, automatic step control, programmable thermostat) Control D is automatic step control suitable for dry and wet environment. This control can be also used for heating mode in winter and cooling in summer. CYKY 3x1,5 (brown, black, yellow-green) o sz o 1 MINIB TT1-DC MINIB TH-0108 contactless c E Control panel D PE ծ\ 0V 5^ Lo Mi Com Hi 24V 2'3r , 2'2r OP MAX7A <§) CD O 'b N O co EMK1 CYKY 3x1,5 (black, black, brown) EMK2 EMKn CO CL O O CM CO ■sr ^cfl o > o >co >CD CO o co 93 2 Control D can control cooling of the space if sufficiently cool water is supplied...

 Open the catalog to page 76
MINIB 2009-77

CONTROL E1 Control E1(wet environment, automatic step control, programmable thermostat) Automatic control for convectors used in wet environment. CD r» o oo o CM CM O CM + ■S r» co r» co o co o CM + CD 00 o 00 o CM CM o CM 05 CYKY 3x1,5 (brown, black, yellow-green) K1.1, -cr - o szo 1 (fi Switchboard o MINIB TH-0108 contactless OP Control panel E.1 i MINIB TT3-E1 / (TT5-E1) 3.2R 3.1 C 2.3 c 2.1 c ~12Va ~12Vb Cable UTP5 with terminals RJ45 CYKY 2x1,5 (black, brown) N o TT3-E1 max. 20 A TT5-E1 max. 27 A co ce cl o o CM co a> ^cC o > o >co co CD EMK1 EMK2 Connecting terminals FC 1 Connecting terminals...

 Open the catalog to page 77
MINIB 2009-78

CONTROL E Control E (dry and wet environment, automatic control, programmable thermostat) Fully automatic control of convectors with continuous speed control. The most advanced MINIB controller. CYKY 3x1,5 (brown, black, yellow-green) K1.1, -ori- ro o .Q .c o 1 (fi -1551- MINIB TT1-DC MINIB TH-0108 contactless Switchboard o control panel E 51 0V S Lo Mi txH-i Com 5S-I R OP 11^ 2.1 ˕PE Hi 24V MAX7A <§) CD O N O co EMK1 CYKY 3x1,5 (black, black, brown) EMK2 FC 2 EMKn co cl o o CM CD ■sT ^cC O > o >co >CD CO CD co 93 2 CD lu FC 1 FC n Connecting terminais Connecting terminais Connecting terminais...

 Open the catalog to page 78
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.