Catalog excerpts
INSTALLATION GUIDE - DP CONVECTORS An all-wood free-standing heater which uses the convection heating principle. Since the heater fully uses physical laws of thermodynamics it represents one of the most efficient methods of interior heating. Benefits of free-standing DP convectors: High output Silent operation Low hot water consumption Short response time Design Minimum requirements for operation and maintenance Ball valve - straight !4" 4 Screw fitting - angular W 5 Each position in the table corresponds to Figure No. 1 on aluminum fins through which the heating water flows. tion because other materials (rubber, NBR, silicon) do not provide the required sealing characteristics. 4. straight ball valve - used to shut off water supply. fig. 1: COMPONENTS OF DP CONVECTOR: 1. WOODEN CONVECTOR CASING - the all-wood casing of the convector is a design piece and encases the heat exchanger. 2. CONVECTOR GRILLE - a design piece protecting the convector outlet. It must not be covered!!! 3. HEAT EXCHANGER - copper pipes with pressed- > Select the correct convector position and location - see paragraph 4.1. 4.1 Convector Position The free-standing DP convector made by MINIB is to be floor-mounted. Place the convector so that it does not disturb the overall aesthetic experience of the room. We recommend leaving a 50-150 mm space between the convector and the wall - Figure 2. Never cover the top grille - this would result in flow reduction and a considerable decrease in the convector output (Figure 2). SCREW FITTING - a valve that controls/adjusts heating water flow. HOSE 41 mm HOSE 65 mm - the bellows hose is a stainless hose intended for fitting the connection to the convector exchanger. GASKET - seals joints between valves, hoses, and exchangers (KLINGERSIL C4400). MINIB, a.s. recommends this sealing as the optimal sealing solu- 9. SCREW ANCHOR - for anchoring the screw. 10. SCREW - for fixing the convector to the floor. 11. TEMPLATE - for marking the positions of the inlet and return pipes and for marking the convector fixing holes on the floor. Use: dry environment. } Maximum operating pressure: 1 MPa. } Maximum operating temperature: 90 °C. } Operating medium: water. The use of other media is prohibited. Water may not be mixed with other substances, such as antifreeze fluids! ) Environment: interiors with temperatures ranging between +5 °C and +40 °C. Free-standing DP convectors are designed for installation right on the floor. Please read the following instructions before you start. Plan the exact position before installation. The convector unit (all-wood body) is to be used for determination of the exact position.
Open the catalog to page 1Fix the convector using the supplied mounting accessories. The heat exchanger and the distribution pipes must be connected using the supplied stainless steel hoses. A correctly installed convector is in horizontal position and firmly supported along its entire length The stainless hoses must not be extremely stretched, stressed, or otherwise deformed. Media inlet: The ball valve (included in the standard supply) is always connected to the water inlet. Outlet (return pipe): The control valve is always connected to the outlet pipe. FIG. 6: Insert screw anchors in the prepared holes. Remove the...
Open the catalog to page 2All MINIB catalogs and technical brochures
-
NCA
2 Pages
-
NCA 4P
2 Pages
-
SKB
2 Pages
-
SPB
2 Pages
-
INNOVATIVE ACTIVE CHILLED BEAM
12 Pages
-
NKB
2 Pages
-
NPB
2 Pages
-
NEWS
28 Pages
-
THE BESTSELLING CONvECTORS
52 Pages
-
IG - FLOOR CONVECTORS TE
4 Pages
-
IG - SK CONVECTORS
2 Pages
-
IG - KZ CONVECTORS
2 Pages
-
FLOOR CONVECTORS with fan
47 Pages
-
CONTROL ACCESSORIES
24 Pages
-
CONTTROLS
3 Pages
-
WALL-MOUNTED AND FREE-STANDING
40 Pages
-
FLOOR CONVECTORS
72 Pages
-
WALL FREE CONVECTORS
36 Pages
-
DESIGN CONVECTORS
12 Pages
-
NEWS MINIB
3 Pages
-
BEST OF MINIB
11 Pages
-
CATALOGUE MINIB
108 Pages
-
COIL – PT300
1 Pages
Archived catalogs
-
COIL – SK PTG - NK PTG
1 Pages
-
COIL - SW250
1 Pages
-
COIL- SP2/4
1 Pages
-
COIL – SP1/4
1 Pages
-
COIL – NP2/4
1 Pages
-
COIL – NP1/4
1 Pages
-
COIL – SU2
1 Pages
-
COIL – SU1
1 Pages
-
COIL – NU2
1 Pages
-
COIL – NU1
1 Pages
-
COIL – DP
1 Pages
-
COIL – LP
1 Pages
-
COIL – SK2
2 Pages
-
COIL – SK1
2 Pages
-
COIL – NK1
2 Pages
-
COIL – KP
1 Pages
-
COIL – TE
1 Pages
-
COIL-KT3 105
2 Pages
-
COIL – KT110
2 Pages
-
COIL – MT2
2 Pages
-
COIL – KT3
2 Pages
-
COIL – HCM4pipe
2 Pages
-
COIL – HCM
2 Pages
-
COIL – HC4pipe
2 Pages
-
COIL – HC
2 Pages
-
COIL – M0
2 Pages
-
COIL – MT
2 Pages
-
COIL – KT2
2 Pages
-
COIL – KT1
2 Pages
-
COIL – T 60
2 Pages
-
COIL – KTO
2 Pages
-
COIL – T80
2 Pages
-
COIL-T50
2 Pages
-
COIL – KT
2 Pages
-
COIL – KO
2 Pages
-
COIL – PW
1 Pages
-
COIL – PT180
1 Pages
-
COIL – PT80
1 Pages
-
COIL – PO
1 Pages
-
COIL – PT
1 Pages
-
COIL – P
1 Pages
-
COIL – SW420
1 Pages
-
COIL – NW340
1 Pages
-
COIL – NW170
1 Pages
-
COIL – PMW205
1 Pages
-
COIL – PMW165
1 Pages
-
COIL – PT105
1 Pages
-
COIL – PMW90
1 Pages
-
COIL – PMW125
1 Pages
-
Minib TH-0343 Termostat
1 Pages
-
Minib TH-0108 Termostat
88 Pages
-
MINIB 2009
88 Pages