FLOOR CONVECTORS with fan
47Pages

{{requestButtons}}

Catalog excerpts

FLOOR CONVECTORS with fan - 1

FLOOR CONVECTORS with fan

Open the catalog to page 1
FLOOR CONVECTORS with fan - 2

ABOUT THE PRODUCTS ABOUT THE COMPANY MINIB is one of the foremost manufacturers of convectors within the Czech Republic. All MINIB products are manufactured in the Czech Republic from where they are exported to over thirty European countries, Asia, Australia and America. Operating since 1999, the company has systematically invested in the development of its products and production techniques and continues to do so. This investment is aimed at providing customers with the ultimate in technical and aesthetic heating and cooling equipment. MINIB operates from a strong financial base and has...

Open the catalog to page 2
FLOOR CONVECTORS with fan - 3

CONTENTS FLOOR CONVECTORS WITHOUT A FAN FLOOR CONVECTORS WITH A FAN Coil P Coil P80 Coil PT Coil PT4 Coil PT80 Coil PT105 Coil PT180 Coil PT300 Coil PO Coil PO4 Coil PMW125 Coil PMW90 Coil PMW165 Coil PMW205 type of grille more on p. 66 TEMPERATURE EQUATION Coil KT Coil MT Coil KT110 Coil KO Coil MO Coil KT0 Coil KT1 Coil KT2 Coil KO2 Coil KT3 Coil KT3 105 Coil T50 Coil T60 Coil T80 Coil TO85 Coil HC Coil HC4pipe Coil HCM Coil HCM4pipe Coil TE Coil SK Coil KP TEMPERATURE EQUATION FOR COOLING where: temperature exponent mean temperature of heating water, air temperature in the interior (°C)...

Open the catalog to page 3
FLOOR CONVECTORS with fan - 4

CROSS-SECTIONS OF CONVECTORS FLOOR CONVECTORS WITHOUT A FAN

Open the catalog to page 4
FLOOR CONVECTORS with fan - 5

floor convectors with fan – dry environment COIL- KT TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Basic and most popular floor convector with a fan of the KT/MT series CHARACTERISTICS • highly efficient forced convection heating • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height length connection

Open the catalog to page 5
FLOOR CONVECTORS with fan - 6

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 6
FLOOR CONVECTORS with fan - 7

floor convectors with fan – dry environment COIL- MT TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Most efficient floor convector with a fan of the KT/MT series CHARACTERISTICS • very highly efficient forced convection heating • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height length connection

Open the catalog to page 7
FLOOR CONVECTORS with fan - 8

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 8
FLOOR CONVECTORS with fan - 9

floor convectors with fan – dry environment COIL- KT110 TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Lowest floor convector with a fan of the KT/MT series CHARACTERISTICS • high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height length connection

Open the catalog to page 9
FLOOR CONVECTORS with fan - 10

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 10
FLOOR CONVECTORS with fan - 11

floor convectors with fan – wet environment COIL- KO TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Most common floor convector with a fan for an interior with a wet environment CHARACTERISTICS • high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • safe 12V AC voltage • suitable primarily for swimming pools • simple control DIMENSIONS width structural height length connection

Open the catalog to page 11
FLOOR CONVECTORS with fan - 12

with fan – wet environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 12
FLOOR CONVECTORS with fan - 13

floor convectors with fan – wet environment COIL- MO TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Most efficient floor convector with a fan for an interior with a wet environment CHARACTERISTICS • very high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • safe 12V AC voltage • suitable primarily for swimming pools • simple control The convector cannot be installed for a swimming pool with salty or otherwise corrosive water DIMENSIONS width structural height length connection

Open the catalog to page 13
FLOOR CONVECTORS with fan - 14

with fan – wet environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 14
FLOOR CONVECTORS with fan - 15

floor convectors with fan – dry environment COIL- KT0 TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Narrowest floor convector with a fan of the MINIB company CHARACTERISTICS • high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height length connection

Open the catalog to page 15
FLOOR CONVECTORS with fan - 16

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. 80 mean water temperature tW

Open the catalog to page 16
FLOOR CONVECTORS with fan - 17

floor convectors with fan – dry environment COIL- KT1 TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Narrow floor convector with a fan CHARACTERISTICS • high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height length connection

Open the catalog to page 17
FLOOR CONVECTORS with fan - 18

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. mean water temperature tW

Open the catalog to page 18
FLOOR CONVECTORS with fan - 19

floor convectors with fan – dry environment COIL- KT2 TEMPERATURE EXPONENT ELECTRICAL POWER FOR FANS length Floor convector with a fan with optional input of fresh air CHARACTERISTICS • connection to ventilation outlet • very high forced convection heating efficiency • rapidly reacting heating unit • heats even when the fan is turned off • low electrical energy consumption • safe 12V DC voltage • simple control DIMENSIONS width structural height spiggot length connection

Open the catalog to page 19
FLOOR CONVECTORS with fan - 20

with fan – dry environment floor convectors THERMAL OUTPUT Q [W] Level 1 minimum r.p.m. 45 mean water temperature tW

Open the catalog to page 20

All MINIB catalogs and technical brochures

  1. NCA

    2 Pages

  2. NCA 4P

    2 Pages

  3. SKB

    2 Pages

  4. SPB

    2 Pages

  5. NKB

    2 Pages

  6. NPB

    2 Pages

  7. NEWS

    28 Pages

  8. CONTTROLS

    3 Pages

  9. NEWS MINIB

    3 Pages

  10. BEST OF MINIB

    11 Pages

  11. CATALOGUE MINIB

    108 Pages

Archived catalogs

  1. COIL - SW250

    1 Pages

  2. COIL- SP2/4

    1 Pages

  3. COIL – SU2

    1 Pages

  4. COIL – SU1

    1 Pages

  5. COIL – NU2

    1 Pages

  6. COIL – NU1

    1 Pages

  7. COIL – DP

    1 Pages

  8. COIL – LP

    1 Pages

  9. COIL – SK2

    2 Pages

  10. COIL – SK1

    2 Pages

  11. COIL – NK1

    2 Pages

  12. COIL – KP

    1 Pages

  13. COIL – TE

    1 Pages

  14. COIL – MT2

    2 Pages

  15. COIL – KT3

    2 Pages

  16. COIL – HCM

    2 Pages

  17. COIL – HC

    2 Pages

  18. COIL – M0

    2 Pages

  19. COIL – MT

    2 Pages

  20. COIL – KT2

    2 Pages

  21. COIL – KT1

    2 Pages

  22. COIL – KTO

    2 Pages

  23. COIL – T80

    2 Pages

  24. COIL-T50

    2 Pages

  25. COIL – KT

    2 Pages

  26. COIL – KO

    2 Pages

  27. COIL – PW

    1 Pages

  28. COIL – PO

    1 Pages

  29. COIL – PT

    1 Pages

  30. COIL – P

    1 Pages

  31. MINIB 2009

    88 Pages