1. Catalogs
  2. MINIB
  3. CONTROL ACCESSORIES
video corpo

CONTROL ACCESSORIES

CONTROL ACCESSORIES
1 / 24 PagesView full catalog

CONTROL ACCESSORIES

Product catalog summary
Company Overview
MINIB, a.s. is a Czech company specializing in the manufacture of convectors, exporting to over thirty countries. Established in 1999, the company emphasizes innovation and invests in research and development to offer advanced technical and aesthetic solutions. It is economically stable, supporting continuous investment in technology and human resources.
Manufacturing Process
The manufacturing facility in Býkev near Mělník is equipped with advanced CNC machines. MINIB offers a ten-year warranty on heat exchangers and stainless steel convector troughs, using high-quality materials. The company is ISO 9001:2009 certified and tests products according to EN 442-2 standards.
Product Overview
MINIB provides over 70 types of convectors for various environments, designed for energy efficiency and low space requirements. The range includes floor, free-standing, wall-mounted, and design convectors, with customization options available.
Control Systems
Heating output is controlled by regulating water supply to the heat exchanger, with manual or automatic options. Since 2005, 12 V DC brushless motors have been used for lower power consumption and noise. Control units (EB-A, EB-B, EB-C) offer fan speed adjustment and protection against overheating.
Wiring and Connection
Specific conductor cables are used for different control types. The EB units should not be connected when energized, and thermostats require suitable cables. The ADA-EB adaptor connects non-standard thermostats, converting voltage signals for fan-coil units.
EBI-2e Electronic Unit
The EBI-2e unit controls DC motors for convector fans, supporting heating and cooling modes with specific conditions for fan operation. It includes LED indicators and multiple outlets for DC motors.
Specifications
  • Power Supply: AC and DC, with a safety transformer 230 V AC/12 V AC.
  • Outputs: 3x for DC motor, 2x for valve (short-circuit resistant).
  • Inputs: 2x for thermistor temperature sensor, 0-10 V DC analog signal control.
  • Modes: Heating and cooling mode distinction, motor speed detection, and optical indications for synchronization and temperature adequacy.
  • Maximum Values: AC supply voltage 15 V, DC supply voltage 20 V, output current for motor 2.5 A, valve 0.3 A, operating temperature 0-85 °C.
Connection and Control
  • Motor and sensor connections are specified with detailed pin functions for each connector.
  • Control of convectors is achieved through various methods including potentiometers, thermostats, and superior systems (BMS).
  • Control units like EB-A, EB-B, and EB-C offer different functionalities for fan speed and mode adjustments.
Operational Modes
  • Heating Mode: Fans activate when water temperature exceeds 30 °C and control voltage is above 2 V. Speed is adjustable between 2-10 V DC.
  • Cooling Mode: Activated by switching +12 V DC to terminal 8. Fans operate when water temperature is below 18 °C and control voltage is above 2 V.
Installation Guidelines
  • Conductor cross-sections should be chosen based on current loading and cable length, with a maximum distance of 15 m between convector and transformer.
  • For installations with more than five convectors, the thermostat should be connected to the nearest convector to the transformer.
Specifications and Power Calculations
Electric power inputs for different convector models are calculated, with KO convectors requiring 434 VA, T80 and KT convectors requiring 64 VA and 180 VA respectively, totaling 293 VA.
Transformer Selection
Transformers are selected with a 20% output reserve. KO convectors require 521 VA, covered by two TT300-E2 transformers. T80 and KT convectors require 293 VA, covered by one TT300 transformer.
Control Elements and Accessories
Control elements include thermostats and transformers. The EB-C control manages fan speeds and automatic modes. Accessories such as thermostatic valves, ball valves, hoses, and electrothermic heads are listed.
Procedure for Control Selection
Guidelines for selecting controls and transformers based on environmental conditions and client comfort are provided.
Contact Information
Contact details for MINIB, a.s., including phone numbers and email addresses for foreign trade inquiries, are provided.
See more

Catalog excerpts

CONTROL ACCESSORIES-1

CONTROL ACCESSORIES

 Open the catalog to page 1
CONTROL ACCESSORIES-2

ABOUT THE PRODUCTS Minib’s product portfolio includes more than 70 types of convectors. Customers can therefore choose the suitable convector for any interior environment. ABOUT THE COMPANY MINIB, a.s. is an entirely Czech business which ranks among the leading manufacturers of convectors in the Czech Republic. It currently exports its products to thirty countries in Europe, Asia, Australia, and America. Since 1999, MINIB has been systematically innovating production technology and its products, and it invests quite considerable amounts in its own development and design, with the goal of offering...

 Open the catalog to page 2
CONTROL ACCESSORIES-3

Control unit - EB Blok EBI-2e 5 Use of non-standard thermostats, converter ADA-EB 10 Manual control of the supply of the heating (cooling) water 11 Control by means of a superior system - EB Blok EBI-2e 12 Control by means of a superior system - EB Blok EBI-2r 13 E2 control with multiple transformers 17 Procedure for selection of suitable control Thermostatic valves Anti-vibration sheet

 Open the catalog to page 3
CONTROL ACCESSORIES-4

CONTROL PRINCIPLE The heating output of convectors is controlled by opening / shutting off the heating or cooling water supply to the heat exchanger. The supply is controlled either manually (thermostatic head), or automatically by the convector electronics (electrothermic head). The output of convectors with fans is also controlled by adjusting the fan speed. OUTPUT CONTROL – CONVECTORS FOR STANDARD (DRY) ENVIRONMENT Since 2005 MINIB has been using 12 V DC brushless motors in its fans intended for standard environment. The advantage of these motors consists in significantly lower power consumption...

 Open the catalog to page 4
CONTROL ACCESSORIES-5

dry environment - output control Control of MINIb convectors with a single-circuit heat The EBI-2e electronic unit (a part of the convector) is intended to control the direct current (DC) low voltage brushless motors used as drives for heating convector fans with a single-circuit heat exchanger. This is a microprocessor controlled unit on a double-sided printed circuit board (PCB) with dimensions of 57x53 mm and fitted with aluminum casing which also acts as a radiator. EB unit is supplied by safety transformer 230 V AC/12V AC. It is possible to choose between three output versions TT100, TT240...

 Open the catalog to page 5
CONTROL ACCESSORIES-6

output control - dry environment Control of MINIB convectors with a two-circuit heat exchanger (4P) Unlike EBI-2e, the EBI-2r electronic unit (a part of the convector) offers the option to connect two electrothermic heads and two temperature sensors for each circuit of the heat exchanger separately. These properties are used in 4P convectors which are equipped with a heat exchanger with two independent circuits (heating/cooling). EB unit is supplied by safety transformer 230 V AC/12 V AC. It is possible to choose between three output versions TT100, TT240 and TT300 (VA). EB unit must not be connected...

 Open the catalog to page 6
CONTROL ACCESSORIES-7

environment output control Simple control of fan operation by a thermostat; the fan speed can be adjusted ma- nually by the potentiometer located on the wall in the room near the thermostat. The EB electronic control unit is set up for stepless speed control. (Potentiometer can be used independently without a thermostat). Transformers which can be used: TT100, TT240, TT300 Use with convectors with a single-circuit heat exchanger, EB unit EBI-2e. Control: 1. potentiometer MINIB + Thermostat ABB 2. only potentiometer MINIB Optional electrical accessories: electrothermic head 12 V DC NO ANOTHER...

 Open the catalog to page 7
CONTROL ACCESSORIES-8

Fan speed (low, medium, high) is adjusted automatically by the firmware in the EB control unit in orderto achieve required convector output. When the thermostat is turned on the speed is always set to level one. The speed is switched to a higher level always after 15 minutes of thermostat operation (without reaching the required temperature). Transformers which can be used: TT100, TT240, TT300 Use with convectors with a single-circuit heat exchanger, EB unit EBI-2e. Optional electrical accessories: electrothermic head 12 V DC NO ANOTHER SECTION ANOTHER SECTION MULT IPLE THERMOSTAT CH-UO |_ FAN...

 Open the catalog to page 8
CONTROL ACCESSORIES-9

Fan speed (low, medium, high) is adjusted automatically by the firmware in the EB control unit in order to achieve required convector output. When the thermostat is turned on the speed is always set to level one. The speed is switched to a higher level always after 15 mi- nutes of thermostat operation (without reaching the required temperature); the maximum speed, however, is determined by the position of the speed switch on the thermostat (e.g., Transformers which can be used: TT100, TT240, TT300 Use with convectors with a single-circuit and two-circuit heat exchanger, EB unit Optional electrical...

 Open the catalog to page 9
CONTROL ACCESSORIES-10

Connection of the fan coil units control using an ADA-EB adaptorto a non-standard thermostat with 230/24 VAC power supply and control of a boiler, if applicable. CONTROL CONNECTION USING THE AUXILIARY ADAPTOR, POWER SUPPLY When connecting more than five convectors to one transformer it is necessary to connect the thermostat to the convector which in the branch that is closest Conductor cross-sections are chosen according to current loading and the supply cable length. When using the conductor cross-sections specified in this material, the maximum acceptable distance between the convector and...

 Open the catalog to page 10
CONTROL ACCESSORIES-11

The electrothermic head opens the valve at power supply with 12 V DC voltage. The 12 V DC output can be used as an impulse for the auxiliary relay (not supplied by MINIB) which switches any kind of equipment (boiler, pump, head, etc.). Warning: the impulse with 12 V DC will appear after manual switching from OFF to HEAT/COOL (no automatic switching based on the required/currenttemperature). Manual control of the supply of the heating/cooling water to the convector Manual control of the supply of the heating (cooling) water using electrothermic head 12V - heating water electrothermic head 12V...

 Open the catalog to page 11
CONTROL ACCESSORIES-12

convector control using CONNECTION WITH ANOTHER SECTION When control by a superior system is used the EB unit must be set to EB-A control. Transformers which can be used: TT100, TT240, Optional electrical accessories: electrothermic EBI-2e CONTROL by a superior system (BMS) heating-cooling, convectors with a single-circuit heat exchanger When connecting more than five convectors to one transformer it is necessary to connect the thermostat to the convector which in the branch that is closest Conductor cross-sections are chosen according to current loading and the supply cable length. When using...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.