Overview: The document provides technical specifications and performance data for the COIL-T80 fan coil unit, designed by MINIB, s.r.o. It is intended for heating dry interiors with specific requirements for low construction height.
Specifications:
  • Dimensions: Total width is 243 mm, construction height is 80 mm, and length ranges from 900 mm to 3000 mm.
  • Characteristics: The unit is a very low convector (only 80 mm in the floor) and can be supplied with either an aluminium or wooden grille.
Performance Data:
  • The document includes detailed tables showing the heat transfer rate (Q) in watts for various lengths (900 mm to 3000 mm) and mean air temperatures (15°C, 20°C, 22°C) at different mean water temperatures (50°C, 70°C, 80°C, 90°C).
  • Performance is categorized by fan speed: minimum, medium, and maximum.
Usage: The COIL-T80 is designed for individual use in dry interiors with high heating demands and low construction height requirements, where deeper units like COIL-KT or COIL-KT3 cannot be used.
Technical Equation: The document provides a temperature equation for calculating the heat transfer rate (Q) based on the nominal heat transfer rate (QN) and the temperature difference between water and air.
Diagrams: Cross-sectional and longitudinal diagrams of the COIL-T80 are included to illustrate its design and installation.
See more

Catalog excerpts

COIL – T80-2

MINIB, s. r. o., Støešovická 49, 162 00 Praha 6 CZ, [email protected] tel.: +420 220 180 780, +420 604 767 677 fax: +420 220 180 779 46 www.minib.cz COIL - T 80 with a fan CHARACTERISTICS 6 for heating dry interiors 6 very low MINIB convector (only 80 mm in the floor) 6 supplied with any aluminium or wooden grille DIMENSIONS total width 243 mm construction height 80 mm length 900 to 3000 mm USAGE Designed for individual use in dry interiors with higher heating demands on intensity of heating and low construction height requirements (up to 80 mm) when the deeper COIL-KT or COIL-KT3 units cannot...