Catalog excerpts
2010/2011 … more than just heat MANUFACTURER OF HEATING CONVECTORS
Open the catalog to page 15 CROSS SECTION of correctors I WALL CONVECTORS WITH FAN I WALL CONVECTORS WITHOUT FAN INSTRUCTION MANUALS
Open the catalog to page 2Introduction Dear customers, Welcome to the new Minib s.r.o catalogue for the year 2010/2011. Along with continuous improvements to existing products we will also be introducing new products and product ranges that we have developed for this year. 1) 2) 3) 4) 5) 6) Important market innovations for the year are represented by ranges of products which combine aesthetically pleasing design with effective heat transfer through either convection or radiation. The innovative wall-mounted units are notable for their flat construction which enables the use of materials such as granite, glass or...
Open the catalog to page 3Introduction Table of contents The company is able to manufacture most styles of convectors according to the customer‘s specific requirements. With prior agreement the company can provide performance testing of individual units in the approved (accredited) test chamber according to EN 442-2. FREQUENTLY ASKED QUESTIONS 1) When is it suitable to choose MINIB convectors? MINIB water heated convectors are specifically designed for installation below large window surfaces, under terraced doors, in winter gardens and in swimming pool areas. The units are produced in many standard lengths, but it...
Open the catalog to page 4FLOOR CONVECTORS WITHOUT FANS * dry and wet environment is defined by the standard CSN 038900 – design of electric objects – Classification of the environment TEMPERATURE EQUATION: CALCULATION OF THE OUTPUT FOR THE PARTICULAR TEMPERATURES: Use the temperature equation for calculation of the output at other than the tabulated value of heating water and air in the room. Enter the required mean temperature of heating water and air in the room and calculate the heat output. These values can be also simply calculated on our website on the specific convector page. PRICE OF THE STANDARD CONVECTOR...
Open the catalog to page 8without fan – wet interiors Floor convectors COIL – PO CHARACTERISTICS 6 for heating wet interiors 6 the most popular convector without a fan DIMENSIONS total width construction height length 303 mm 125 mm 900 to 3000 mm USAGE COIL PO has a formed drain pan to provide drainage of stored water from the trough drain pan. COIL PO can be combined with the COIL – KO and COIL – MO, which have a significantly higher heat output These convectors are equipped with an 18 mm CU drain tube placed in the front of the convector. The convector cannot be installed to swimming pools with salt or other...
Open the catalog to page 17Floor convectors without fan – wet interiors COIL – PO4 CHARACTERISTICS 6 6 for heating wet interiors identical in dimension to convectors PO but it has the 4 – tube heat exchanger and therefore a higher output Q DIMENSIONS total width construction height length 303 mm 125 mm 900 to 3000 mm USAGE HEAT TRANSFER RATE q [W] coil – Po4 length L (mm) 900 mean air temperature tA mean water temperature tW 15 20 22 90 567 513 492 70 362 315 297 60 270 228 212 150 115 102 45 COIL PO/4 is recommended for individual use in interiors where COIL PO does not efficiently cover the heat requirement. COIL...
Open the catalog to page 18FLOOR CONVECTORS WITH FANS HOW TO CORRECTLY CHOOSE TEMPERATURE EQUATION FOR HEATING A FLOOR CONVECTOR WITH A FAN: where: - determination of the heat loss in the room according tw - ta m m= temperature exponent to the project mean heating water temperature tW, A Q=µ QN - determination of the mean heating water temperature mean air temperature in the interior [°C] 50 - setting of the required temperature in the room nominal heat transfer rate for QN temperatures tW/tA 70/20 °C [W] - setting of the convector type according to the environment µ µ=1 (select µ according to the diagram for (dry or...
Open the catalog to page 23Floor convectors with fan – wet interiors coil – KT CHARACTERISTICS 6 6 6 6 the most popular convector with fan for heating dry interiors high heat output also heating when the fan is switched off DIMENSIONS total width construction height length L 303 mm 125 mm 900 to 3000 mm USAGE Temperature exponent CROSS SECTION of COIL-KT m = 1,012688 63 75 12 VA 12 VA 1250 24 VA 1500 24 VA 1750 24 VA 2000 36 VA 2500 48 VA 3000 48 VA 305 LONGITUDINAL SECTION OF COIL-KT 72 62 136 101 24 www.minib.com Ø30 900 1000 DC motor 125 power input 63 61 ELECTRIC INPUT FOR FANS Ø30 303 52 length Window The most...
Open the catalog to page 24Floor convectors with fan – dry interiors coil – KT 110 CHARACTERISTICS 6 6 6 6 for heating dry interiors high heat output also heating when the fan is switched off KT110 variant with lower demands on construction height DIMENSIONS total width construction height length L 303 mm 110 mm 900 to 3000 mm USAGE m = 1.0543 power input 900 12 VA 1000 12 VA 1250 24 VA 24 VA 36 VA 48 VA 3000 48 VA LONGITUDINAL SECTION OF COIL-KT110 136 101 www.minib.com Ø30 2500 305 60 50 1750 2000 26 63 24 VA 1500 DC motor 303 75 110 length 63 50 ELECTRIC INPUT FOR FANS 51 Ø3 0 CROSS SECTION of COIL-KT110...
Open the catalog to page 26Floor convectors with fan – dry interiors coil – KO CHARACTERISTICS 6 6 6 6 the most popular convector with the fan for heating wet interiors high heat output also heating when the fan is switched off DIMENSIONS total width construction height length L 303 mm 125 mm 900 to 3000 mm USAGE m = 1,012688 51 63 303 75 63 37 VA 37 VA 1500 64 VA 1750 74 VA 2000 74 VA 2500 106 VA 3000 111 VA www.minib.com 305 Ø1 8 LONGITUDINAL SECTION OF COIL-KO 136 101 Ø30 1250 28 32 VA 72 62 900 1000 125 AC power input motor 116 length 61 ELECTRIC INPUT FOR FANS Ø3 0 CROSS SECTION of COIL-KO Temperature exponent...
Open the catalog to page 28Floor convectors with fan – wet interiors coil – kt0 CHARACTERISTICS 6 he narrowest available MINIB floor convector, total t width only 106 mm 6 or heating dry interiors f DIMENSIONS total width construction height length L 106 mm 125 mm 900 to 3000 mm USAGE The convector COIL – KT0 is MINIB‘s narrowest available floor convector. It is a fast-responding heater from the lower heat output series of MINIB convectors with the 12V fan. Despite the extremely narrow design, the convector can achieve heat outputs of approx. 420 W/m of length. Their use is recommended in cases when an extremely...
Open the catalog to page 30All MINIB catalogs and technical brochures
-
NCA
2 Pages
-
NCA 4P
2 Pages
-
SKB
2 Pages
-
SPB
2 Pages
-
INNOVATIVE ACTIVE CHILLED BEAM
12 Pages
-
NKB
2 Pages
-
NPB
2 Pages
-
NEWS
28 Pages
-
THE BESTSELLING CONvECTORS
52 Pages
-
IG - FLOOR CONVECTORS TE
4 Pages
-
IG - DP CONVECTORS
2 Pages
-
IG - SK CONVECTORS
2 Pages
-
IG - KZ CONVECTORS
2 Pages
-
FLOOR CONVECTORS with fan
47 Pages
-
CONTROL ACCESSORIES
24 Pages
-
CONTTROLS
3 Pages
-
WALL-MOUNTED AND FREE-STANDING
40 Pages
-
FLOOR CONVECTORS
72 Pages
-
WALL FREE CONVECTORS
36 Pages
-
DESIGN CONVECTORS
12 Pages
-
NEWS MINIB
3 Pages
-
BEST OF MINIB
11 Pages
-
COIL – PT300
1 Pages
Archived catalogs
-
COIL – SK PTG - NK PTG
1 Pages
-
COIL - SW250
1 Pages
-
COIL- SP2/4
1 Pages
-
COIL – SP1/4
1 Pages
-
COIL – NP2/4
1 Pages
-
COIL – NP1/4
1 Pages
-
COIL – SU2
1 Pages
-
COIL – SU1
1 Pages
-
COIL – NU2
1 Pages
-
COIL – NU1
1 Pages
-
COIL – DP
1 Pages
-
COIL – LP
1 Pages
-
COIL – SK2
2 Pages
-
COIL – SK1
2 Pages
-
COIL – NK1
2 Pages
-
COIL – KP
1 Pages
-
COIL – TE
1 Pages
-
COIL-KT3 105
2 Pages
-
COIL – KT110
2 Pages
-
COIL – MT2
2 Pages
-
COIL – KT3
2 Pages
-
COIL – HCM4pipe
2 Pages
-
COIL – HCM
2 Pages
-
COIL – HC4pipe
2 Pages
-
COIL – HC
2 Pages
-
COIL – M0
2 Pages
-
COIL – MT
2 Pages
-
COIL – KT2
2 Pages
-
COIL – KT1
2 Pages
-
COIL – T 60
2 Pages
-
COIL – KTO
2 Pages
-
COIL – T80
2 Pages
-
COIL-T50
2 Pages
-
COIL – KT
2 Pages
-
COIL – KO
2 Pages
-
COIL – PW
1 Pages
-
COIL – PT180
1 Pages
-
COIL – PT80
1 Pages
-
COIL – PO
1 Pages
-
COIL – PT
1 Pages
-
COIL – P
1 Pages
-
COIL – SW420
1 Pages
-
COIL – NW340
1 Pages
-
COIL – NW170
1 Pages
-
COIL – PMW205
1 Pages
-
COIL – PMW165
1 Pages
-
COIL – PT105
1 Pages
-
COIL – PMW90
1 Pages
-
COIL – PMW125
1 Pages
-
Minib TH-0343 Termostat
1 Pages
-
Minib TH-0108 Termostat
88 Pages
-
MINIB 2009
88 Pages