MHG Brochure
12Pages

{{requestButtons}}

Catalog excerpts

MHG Brochure - 1

Premium Heating Technology MHG Heating Ltd – Simply better.

Open the catalog to page 1
MHG Brochure - 2

Premium quality made in Germany MHG Heiztechnik GmbH the parent company of MHG Heating Ltd is one of the leading German providers of high-quality heating systems and components for oil, gas, wood pellets and solar technology. Originally part of the MAN Group, we are now an independent, owner-managed company that can look back on more than 80 years of tradition. With Haspa Beteiligungsgesellschaft für den Mittelstand mbH, Hamburg, we have a financially strong and longterm oriented partner at our side. Its parent company, Hamburger Sparkasse AG, with total assets of 34 billion euros, is...

Open the catalog to page 2
MHG Brochure - 3

MHG’s head offices are in Buchholz near Hamburg. Our specialist engineers are intensively trained in the technical features of our top-quality heating products as part of our real-life-scenario training programme. The high degree of maintainability of our devices eases the work of technicians.

Open the catalog to page 3
MHG Brochure - 4

Technical data ProCon Streamline Nominal heat output at 50/30 °C Efficiency at 40/30 °C Dimensions (H x W x D) Max. pressure at flue gas outlet Technical data Allowable flue gas connection types Nominal heat output at 50/30 °C Max. pressure at flue gas outlet CE-0063AR3527 Product IDs 16H = 20 mg/kWhr 25H = 22 mg/kWhr 16/24S = 22 mg/kWhr 25/32 S = 34 mg/kWhr 25/32 Flash = 34 mg/kWhr Hot water continuous output at T = 30K Allowable flue gas connection types CE-0085AT0424 16H = 30 mg/kWhr 27H = 12 mg/kWhr 27S = 12 mg/kWhr Kompakt = < 12 mg/kWhr Hot water continuous output at T = 30K All...

Open the catalog to page 4
MHG Brochure - 5

Technical data Technical data Nominal heat output at 50/30 °C Max. pressure at flue gas outlet Allowable flue gas connection types Nominal heat output at 50/30 °C Max. pressure at flue gas outlet Allowable flue gas connection types 47H = 28 mg/kWhr 47S = 28 mg/kWhr 75H = 29 mg/kWhr Hot water continuous output at T = 30K Hot water continuous output at T = 30K All appliances supplied with a 24 month warranty All appliances supplied with a 24 month warranty The best features at a glance The best features at a glance Wall-mounted premium gas-condensing boilers specially designed for use in...

Open the catalog to page 5
MHG Brochure - 6

Technical data Air/water heat pumps split units R407c* ThermiStar L .., L .. T, L .. E Heating/refrigerating performance* Performance coefficient* * Performance data and COP for A2/W35, expanded scale of 3K at source and 10K on heating side; larger performances on request Brine/water heat pumps R407c*, ThermiStar S .., S .. T, S .. T, S .. E Heating/refrigerating performance* Performance coefficient* * Performance data and COP for B0/W35, expanded scale of 3K at source and 10K on heating side; larger performances on request Water/water heat pumps R407c*, ThermiStar W Heating/refrigerating...

Open the catalog to page 6
MHG Brochure - 7

Technical data THERAMAT tank Technical data Unit Nominal capacity THERAMAT EMT (HWS Calorifiers/storage tanks) External dimensions THERAMAT EM (HWS Calorifiers/storage tanks) Gross area THERAMAT ES (HWS Calorifiers/storage tanks) Effective absorber area THERAMAT EMH (HWS Calorifiers/storage tanks) THERAMAT EMS (Solar HWS Calorifiers/tanks) Absorber design THERAMAT SZ (HWS Calorifiers/heat pump tanks) Optical coefficient THERAMAT SP (Buffer tanks) THERAMAT SK (Combination tanks) SOLARMAT SOLARMAT SOLARMAT SOLARMAT FL/K 420 DH FL/K 420 EM CPC 14 CPC 21 Compound Parabolic Concentrator The best...

Open the catalog to page 7
MHG Brochure - 8

Technical data EcoStar 200 Nominal thermal output Standard efficiency Exhaust temperature* Technical data EcoStar 222 Nominal thermal output Standard efficiency Exhaust temperature* * The quoted exhaust temperatures are based on a flow temperature of 75 °C * The quoted exhaust temperatures are based on a new boiler at a flow temperature of 60 °C The best features at a glance The best features at a glance High-performance oil unit in proven low-temperature design for installation in homes and commercial buildings Exclusive use of premium components (cast-iron boiler, Rocket Burner®, comfort...

Open the catalog to page 8
MHG Brochure - 9

Technical data EcoStar 500 Nominal thermal output EcoStar 500: The best features at a glance High-tech oil-condensing system for installation in homes and commercial buildings Innovative, patented high-performance glass pipe heat exchanger for maximum energy efficiency, operational safety and long service life: glass does not rust! Up to 30 per cent savings on heating costs thank to perfect, soot-free burning process and heat recovery with optimum use of combustion heat Top standard efficiency of up to 104 per cent Exclusive use of premium components (Rocket Burner®, cast-iron boiler, glass...

Open the catalog to page 9
MHG Brochure - 10

Technical data Technical data Unit Boiler output Oil burner, single-stage (On-Off) 15–70 Rocket Burner® (oil burner), double-stage (Hi-Lo) RZ 2.6–RZ 3.3 Boiler output Rocket Burner® (oil burner), single-stage (On-Off) Oil burner, double-stage (Hi-Lo) DZ 2.1–4.2 Rocket Burner®: The best features at a glance The best features at a glance Single- (On-Off) and double-stage (Hi-Lo)-high-tech oil burner with blue flame technology Converts oil into gas: extremely low heating-oil consumption and very low emissions thanks to perfect sootfree burning process Now in its third generation with sales in...

Open the catalog to page 10
MHG Brochure - 11

Technical data Technical data Unit Boiler output Gas forced-air burner, single-stage (On-Off) Boiler output Combination burner Gas forced-air burner, double-stage (Hi-Lo) The best features at a glance The best features at a glance Single- (On-Off) and double-stage (Hi-Lo) gas forced-air burner for use with natural gas or LPG Highly mature, tried-and-tested products Energy-saving and environmentally friendly Single-stage (On-Off) burner used in the Rocket Burner® casing ensures optimal start-up, particularly stable burning and high levels of operational safety. Double-stage (Hi-Lo) burner in...

Open the catalog to page 11
MHG Brochure - 12

MHG Heiztechnik GmbH Germany kontakt@mhg.de www.mhg.de MHG Heating Ltd UK Telephone: 0845 6448802 Fax : 0845 6448803 Email: info@mhgheating.co.uk Web: www.mhgheating.co.uk

Open the catalog to page 12

All MHG Heating catalogs and technical brochures

  1. Alucon

    2 Pages

Archived catalogs

  1. gz2

    28 Pages