Catalog excerpts
Casement windows and doors
Open the catalog to page 1Casement windows Excellent structural quality and aesthetics, good taste and technology together to enhance and protect the living spaces. Great versatility but never forgetting the external look... the METRA casement windows and entrance doors are suitable for all architectural requirements: from the historical centres to the contemporary architecture, from the mountain chalet to the villa at the beach or in the countryside. Resistant to any type of atmospheric agent and climate, with long-lasting performances, the METRA casement windows ensure a valid acoustic Insulation and great energy...
Open the catalog to page 2METRA Quality 3 - Glazing bead available in different sizes depending on glass thickness 4 - Insulating glass with one air space (double glazing) or two air spaces (triple glazing) 5 - EPDM gasket for glazing 6 - Insulating bars made of polyamide 6.6 reinforced with 25% fibreglass 7 - Open joint tightness central gasket 8 - EPDM internal rabbet basket 9 - Insulating bars which reduce the heat dispersion 10 - Under-glass insulating gasket Purchasing METRA trademark profiles and accessories gives the security of using materials that guarantee the highest performances and durability. METRA...
Open the catalog to page 3Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Rabbet double gasket (entrance doors) Glass thickness: Aesthetic lines: Piana, Sagomata Water tightness Wind load resistance max Horizontal section
Open the catalog to page 4Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Rabbet double gasket (entrance doors) Glass thickness: Aesthetic lines: Piana, Sagomata, Raggiata, Ferro, Tonda Water tightness Wind load resistance max Sound insulation Thermal transmittance Burglar resistance 1 vent window 1230 x 1480 mm; glass: Ug=0.6 W/m2K, psi=0.05 W/mK
Open the catalog to page 6Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Glass thickness: Aesthetic lines: Piana, Sagomata, Raggiata, Ferro, Scomparsa Horizontal section Water tightness Wind load resistance max Sound insulation Thermal transmittance * 1 vent window 1230 x 1480 mm; glass: Ug=0.6 W/m2K, psi=0.05 W/mK Burglar resistance Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 8Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Glass thickness: Aesthetic lines: Piana, Sagomata, Raggiata, Ferro, Scomparsa Horizontal section Water tightness Wind load resistance max with deflec- Sound insulation Thermal transmittance * 1 vent window 1230 x 1480 mm; glass: Ug=0.6 W/m2K, psi=0.05 W/mK Burglar resistance Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 10Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Glass thickness: Aesthetic lines: Piana, Sagomata, Raggiata, Scomparsa Horizontal section Water tightness Wind load resistance max Sound insulation Thermal transmittance * 1 vent window 1230 x 1480 mm; glass: Ug=0.6 W/m2K, psi=0.05 W/mK Burglar resistance Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 12Basic dimensions: Air-water-wind tightness: Open joint (windows and French windows) Glass thickness: Aesthetic lines: Piana, Sagomata, Raggiata, Scomparsa Horizontal section Water tightness Wind load resistance max Sound insulation Thermal transmittance * 1 vent window 1230 x 1480 mm; glass: Ug=0.6 W/m2K, psi=0.05 W/m K Burglar resistance Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 14Casement doors The METRA entrance doors fit with style in any archi- tectural context and resist to any climatic condition. They belong to a class of highest performances: they can have double or triple gasket for a perfect tightness to the atmospheric agents. They are secure, strong and non-deformable, they meet the strictest requirements in terms of aesthetics, functionality and energy saving. METRA entrance doors offer many exciting surfaces, so many colours and effects, wide choice of cutting for glazed parts and great style design for the original accessories (handles and hinges). •...
Open the catalog to page 16• Maximum thermal insulation • Maximum acoustic insulation • Unalterable and long lasting • Burglar-proof security • Thin hinges which give to the door a pleasant and elegant look • Panel with high thermal and acoustic insulation, provided with an elastic joint suitable to solve the problem of the "Bi-metal-effekt" even in conditions of remarkable exposure • Plugging or crimping corner cleats with injection of glue • Wide range of mechanical and electric locks (automatic locking) with relevant catches, even adjustable • Easy maintenance • Maximum opening 2 - Gasket for glazing and/or panel
Open the catalog to page 17Basic dimensions: Air-water-wind tightness: Rabbet double gasket Glass thickness: Aesthetic lines: Piana, Sagomata Horizontal section Water tightness Wind load resistance max Sound insulation Thermal transmittance * 1 vent door 1480 x2180 mm with panel Up=0.5 W/m2K ** 1 vent door 1480 x 2180 mm with glass Ug=1.0 W/m2K, psl=0.05 W/m K Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 18Basic dimensions: : Air-water-wind tightness: Rabbet double gasket Glass thickness: Aesthetic lines: Piana, Sagomata Horizontal section Water tightness Wind load resistance max Sound insulation Thermal transmittance * 1 vent door 1480 x2180 mm with panel Up=0.5 W/m2K ** 1 vent door 1480 X 2180 mm with glass Ug=1.0 W/m2K, psl=0.05 W/m K Operating forces Mechanical strength Resistance to repeated opening and closing - EN 1191 - EN 12400 Impact resistance
Open the catalog to page 20Tightness lower caps Door sill Sash-junction caps Corner cleats The lower caps, placed on the frame and the sash, have been designed to ensure a perimetric seal with total absence of draughts even In the most critical lower parts. the caps enable to optimize Different typologies of door sill are available, In order to offer particular, the new door sill ensures thermal Insulation which prevent from air draughts and water Infiltra- tions. The door sill and the relevant accessories have been designed In order to reduce the time of fabrication available In order to ensure a central section....
Open the catalog to page 22All METRA Building catalogs and technical brochures
-
Facciate continue
37 Pages
-
Oscuranti Shading
27 Pages
-
Porte d'ingresso Entrance doors
52 Pages
-
METRA_Systems-ITA-ING
76 Pages
-
metra building balcony
17 Pages
-
metra-building_shading-systems
27 Pages
-
metra-building_sliding-windows
27 Pages
-
NC-S 150 STH
8 Pages
-
NC-S 120 STH
8 Pages
-
NC 65 STH HES
16 Pages
-
NC 65 STH NC 65 STH-i
8 Pages
-
FRANGISOLE (Sunblades)
16 Pages
-
URANO WALL
20 Pages
-
SYSTEMS FOR HANDRAILS. THEATRON
12 Pages
-
THEATRON Glass line
8 Pages
-
AELLE-S 190 STH
8 Pages
-
AELLE 100 STH
8 Pages
-
NC 90 STH HES
8 Pages
-
AELLE 80 STH
8 Pages
-
NC S65I
4 Pages
-
NC 50 STH
4 Pages
-
NC 75 STH / STH-i
8 Pages
-
DESIGN COMPLEMENTS
4 Pages
-
Sliding Windows
16 Pages
Archived catalogs
-
CURTAIN WALLS
40 Pages
-
Curtain walls_2011
32 Pages
-
Sliding Systems
6 Pages
-
Casement systems
8 Pages