Profiled PUR-insulated roof system, slope p ≥ 7% Table of safe spans Self-supporting metal panel, insulated with PUR-insulation, for pitched roofs with a minimum slope of 7%. For additional technical information, refer to the GLAMET® technical manual. Values guaranteed with external face in steel, 0.5 mm thick, and internal face in steel, 0.4 mm thick or with both faces in aluminium 0,6 mm thick with external face in aluminium, 0.6 mm thick, and internal face in steel, 0.5 mm thick. The spans l (m) as a function of a uniformly distributed overload p (daN/m2), have been obtained from load tests carried out in Metecno laboratories, and provide a deflection f ≤ l/200 with a safety coefficient that complies with the UEAtc standards for insulated panels, which have been established and are implemented by primary European Certifying Organizations. With external and/or internal steel thicknesses inferior to the above mentioned ones, the guarantee on the admissible loads for the spans indicated in the table is maintained, while it is not maintained on the deflection limit and the safety coefficient. Internal side also available: • Centesimal Aluminium • Feltpaper Major product technical approval: Zulassung Dibt Z - 10.4 - 241. Avis Tecnique CSTB AT-2/05-1160 steel - steel 1000 Steel external face Steel internal face aluminium - aluminium Micro-ribbed finish GLAMET® G4 fastening PVC washer Self-tapping screw Ø 6,3 with PVC head Prepainted aluminium cap unit with built-in seal