Cutec®

Cutec®

Product catalog summary
Overview: The document provides technical specifications and details for a profiled PUR-insulated roof system, specifically the Cutec® G4, designed for sloping roofs with a minimum slope of 7%. The system features a self-supporting metal panel insulated with PUR, with an external copper face for aesthetic appeal, making it suitable for residential and prestigious projects.
Specifications: The roof system includes a self-tapping screw with a PVC head, a copper cup unit with a built-in seal, and a profiled PUR-insulated panel. The external face is copper, and the internal face is steel, with thicknesses of 0.5 mm and 0.4 mm, respectively.
Performance and Standards: The table of safe spans provides values guaranteed with the specified material thicknesses. The spans (l) are determined based on a uniformly distributed overload (p) and are tested to ensure a deflection of f ≤ l/200, complying with UEAtc standards for insulated panels.
Technical Data: The document includes a table with various measurements and performance metrics, such as panel weight (kg/m2), thermal conductivity (Watt/m2°C), and other relevant parameters. These values are derived from load tests conducted in Metecno laboratories.
Installation Components: The system includes a sealant, cap fastening assembly unit, screw, and bushing. The copper external face and steel internal face are designed for durability and performance.
Manufacturing: The product is manufactured in Italy, ensuring adherence to European standards and quality.
See more

Catalog excerpts

Cutec®-1

Profiled PUR-insulated roof system, slope p ≥ 7% DESIGN Self-supporting metal panel, insulated with PUR-insulation, with external side in copper for sloping roofs with a minimum slope of 7%. The copper external face gives the panel a more refined look and makes it particularly suitable for residential buildings or prestigious projects. For additional technical information, refer to the CUTEC® technical manual. Cap fastening assembly unit + screw and bushing Copper external face Steel internal face Table of safe spans Values guaranteed with external face in copper 0.5 mm thick, and internal face in steel 0.4 mm thick. The spans l (m) as a function of a uniformly distributed overload p (daN/m2), have been obtained from load tests carried out in Metecno laboratories, and provide a deflection f ≤ l/200 with a safety coefficient that complies with the UEAtc standards for insulated panels, which have been established and are implemented by primary European Certifying Organizations. Micro-ribbed finish CUTEC® G4 fastening Bushing Self-tapping screw Ø 6,3 with PVC head Copper cup unit with built-in seal

 Open the catalog to page 1

All Metecno Bausysteme GmbH catalogs and technical brochures

  1. Metcoppo®

    1  Page

  2. Metenergy®

    1  Page

  3. G4

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.