Fire Ventilation Systems - brochure

Fire Ventilation Systems - brochure

Fire Ventilation Systems - brochure

Product catalog summary
Overview: This document provides detailed specifications and applications for various fire protection and ventilation devices, including fire dampers, smoke exhaust dampers, and fans. It outlines their fire resistance ratings, control mechanisms, dimensions, and intended purposes.
Fire Dampers and Smoke Exhaust Dampers:
  • Specifications: These devices are designed to separate buildings and ensure proper intake and exhaust of air. They are compliant with CE standards according to EN 15650:2010.
  • Fire Resistance: Ratings include EIS 60, EIS 90, EIS 120, and EIS 120 AA, depending on manufacturing and installation methods.
  • Control Mechanisms: Include KW1 and RST mechanisms with fusible links rated at 72°C, and electrical actuators operating at 24V DC or 230V AC.
  • Dimensions: Vary by type, with round dampers ranging from 100-315 mm in diameter and rectangular dampers from 200-1500 mm in width and height.
Fire Protection Devices:
  • Types: Includes duct-mounted axial smoke exhaust fans and exhaust roof fans, compliant with EN 12101-3.
  • Fire Resistance: Ratings include F400, F300, and F200, indicating temperature endurance for specified durations.
  • Purpose: Designed to remove smoke and hot air from enclosed spaces, functioning as exhaust or venting fans.
  • Technical Data: Air output ranges from 32,000 m3/h to 100,000 m3/h, with various diameter options.
Overpressure and Bleed Dampers:
  • Purpose: Maintain desired pressure differences in staircases and other building parts.
  • Control Unit: The mcr Omega control unit manages power and control for overpressure protection dampers.
Applications and Installation:
  • Range of Application: Dampers are used for separating buildings, as intake and exhaust dampers, and in combined systems at the end of ventilation ducts.
  • Installation: Suitable for various building materials, including concrete, bricks, and aerated concrete blocks.
Conclusion: The document provides comprehensive information on the specifications, applications, and installation of fire protection and ventilation devices, emphasizing compliance with relevant standards and the importance of proper installation for optimal performance.
See more

Catalog excerpts

Fire Ventilation Systems - brochure-1

fire ventilation CONTROL SYSTEMS OVERPRESSURE SYSTEMS

 Open the catalog to page 1
Fire Ventilation Systems - brochure-2

fire protection devices examples of application

 Open the catalog to page 2
Fire Ventilation Systems - brochure-3

fire dampers and smoke exhaust dampers de cut-off fire damper amper for fire ventilation systems cut-off fire damper amper for fire ventilation systems Fire resistance of manufacturing, as well as method and Fire resistance depending on method of manufacturing, as well as method and place of installation. Fire resistance S - cut-off fire damper V - for fire ventilation systems (smoke exhaust) M - double-function for combined systems S - cut-off fire damper V - for fire ventilation systems (smoke exhaust) M - double-function for combined systems S - cut-off fire damper The damper has been designed...

 Open the catalog to page 3
Fire Ventilation Systems - brochure-4

fire dampers and smoke exhaust dampers amper, cut-off type and for fire ventilation systems Fire resistance depending on method of manufacturing, as well as method and place of installation. Fire resistance Fire resistance S - cut-off fire damper V - for fire ventilation systems (smoke exhaust) M - double-function for combined systems V - for fire ventilation systems (smoke exhaust) 101 - curtain partially in air stream 201 - curtain outside of air stream 301 - curtain outside of air stream (round damper) The damper has been designed for separating fire-hazardous zones from safe parts of the...

 Open the catalog to page 4
Fire Ventilation Systems - brochure-5

fire protection devices cut-off fire valve Fire resistance Fire resistance Fire resistance Single or double speed motors. Single or double speed motors. -vertically mounted - horizontally mounted The fan has been designed to remove smoke and hot air from enclosed interiors during fire. It facilitates evacuation of people and protects the building structure and its fittings against high temperature, it also prevents the fire spreading to the neighbouring fire comfort and industrial ventilation systems as The fan has been designed to remove smoke and hot air from enclosed interiors during fire....

 Open the catalog to page 5
Fire Ventilation Systems - brochure-6

overpressure systems for vertical evacuation paths Overpressure system: Arrangement and quantity of each system element depend on 1. inspection and measurement elements the requirements, construction and location of the protected 2. smoke sensors staircase, lobby, lift shaft, etc. 6. mcr Omega control unit 7. pressure relief sets/* (roof or wall type) 8. intake-air sets/* (roof or wall type) 9. exhaust air/* (roof or wall type) 7 location and quantity depending on air demand of the system

 Open the catalog to page 6
Fire Ventilation Systems - brochure-7

table of initial choice of devices transfer dampers ventilation and air-conditioning ducts at penetrations through escape corridor made of aerated concrete blocks cut-off dampers for ventilation and air-conditioning ducts smoke exhaust dampers for studs framing

 Open the catalog to page 7