MEIKO TOPIC

MEIKO TOPIC
1 / 60 PagesView full catalog

MEIKO TOPIC

Product catalog summary
Instructions for Use
Users must read and understand the instructions and related documents before using the MEIKO TOPIC washer-disinfector. The product is identified by its model name and comes with necessary documentation.
Declaration of Conformity
The washer-disinfector complies with EU regulations on medical devices and hazardous substances, classified as Class IIa under MDR (EU) 2017/745, certified by mdc medical device certification GmbH.
Safety
  • Correct Use: Intended for cleaning and disinfecting human waste containers like bedpans and urine bottles, to be used by trained nursing staff.
  • Misuse: Includes using the device for non-specified purposes.
  • Safety Information: Use in original condition with proper electrical connections and safety measures. Protective gear is required for handling dosing agents.
Product Description
Overview of product variants, functional description, and available options like detergent dosing and automatic doors.
Technical Data
Specifications detail the machine's requirements and capabilities, including protection degree, noise emission levels, and disinfection performance.
Assembly and Commissioning
Instructions for proper setup and initial operation are included.
Operation/Use
Details on operating the device, including using the membrane keypad, selecting cleaning programs, and handling malfunctions.
Maintenance and Cleaning
Regular maintenance, process validation, and cleaning procedures are outlined to ensure longevity and effectiveness.
Decommissioning and Disposal
Guidelines for safely decommissioning and disposing of the device and its packaging.
Emergency Procedures
Instructions on what to do in case of an emergency, including disconnecting the device from power.
Functional Description
The washer-disinfector operates through four phases: precleaning, cleaning, thermal disinfection, and recooling/drying, complying with DIN ISO 15883 Part 3 standards.
Operation and Use
Features a membrane keypad for selecting cleaning programs with safety warnings. Options for automatic door operation and a code lock are available.
Recommendations and Warnings
Users are advised to clean care utensils immediately after use and follow safety precautions to avoid risks.
Section 8.5: Replace Canister
  • Safety Precautions: Use protective eyewear and gloves.
  • Procedure: Open the door, replace the canister, and ensure the suction lance is vertical.
Section 8.6: Perform Slop Sink Flushing (Option)
  • Precaution: Align cleaning nozzles correctly.
  • Procedure: Empty the container and start the flushing program.
Section 8.7: Wash Chamber Rinsing (Option)
  • Warning: Do not use for cleaning care utensils.
  • Procedure: Empty contents into the wash chamber, close the door, and start the rinsing program.
Section 8.8: Malfunctions
  • Common Issues: Door blockages and incomplete cleaning cycles.
  • Messages: Display provides information, warnings, and error messages.
Section 9: Change Service Level/Settings
  • Precaution: Contact authorized personnel before changing settings.
  • Functions: Change service parameters, ventilate pipes, set date/time, and configure automatic program start.
Specifications and Procedures
Operation and maintenance procedures include instructions for editing parameters and emphasize regular maintenance.
Maintenance and Safety
Tasks include checking electrical safety and dosing systems. Warns against using water hoses or high-pressure cleaners.
Cleaning and Descaling
Daily cleaning involves using appropriate detergents and avoiding aggressive agents. Descaling requires thorough flushing and a liquid descaler.
Non-Usage and Decommissioning
Recommendations for when the appliance is not in use and instructions for decommissioning and disposal.
Disposal
Details the disposal process for packaging materials and old appliances, emphasizing decontamination and compliance with safety regulations.
Additional Information
Includes an index for quick reference to various sections.
See more

Catalog excerpts

MEIKO TOPIC-1

Read the instructions for use before using the appliance! 9694451 / Valid from: 2011-06 / Update: 2025-10

 Open the catalog to page 1
MEIKO TOPIC-2

3.1.5 Determination of activities according to category of personnel 10 3.5 What to do in the event of an emergency 14 4.4.3 Slop sink flushing with separate slop sink unit 19

 Open the catalog to page 2
MEIKO TOPIC-3

8.2 Clean and disinfect care utensils (programme cycle) 26 8.2.1 Clean care utensils (basic version of the appliance) 28 8.2.3 Selecting the cleaning programme 31 8.2.4 Automatic door (AT), operation with sensor (option) 32 8.2.5 Automatic door (AT), operation with foot switch (option) 32 8.2.6 Door lock with code lock / code entry (option) 33 8.3 Factory setting of the A0 value 34 8.6 Perform slop sink flushing (option) 36 8.7 Wash chamber rinsing (option) 37 9.1 Call service levelCall service level 46 9.2 Display or change the list of service parameters 47 9.5 Set time switch for automatic...

 Open the catalog to page 3
MEIKO TOPIC-4

13.1 Disposal of packaging materials 54

 Open the catalog to page 4
MEIKO TOPIC-5

Before using the machine, read the instructions for use and the related documents carefully and keep them in a safe place and within easy reach. All serious incidents relating to the product must be reported to the manufacturer and the competent authority of the Member State. These instructions for use apply to the following models of appliance: MEIKO TOPIC washer-disinfector The delivery contents include: • MEIKO TOPIC washer-disinfector. • Documentation, for details see Related documents. In addition to these instructions for use, there are other documents that are available depending on the...

 Open the catalog to page 5
MEIKO TOPIC-6

Presentation conventions DANGER – indicates an imminently hazardous situation which, if not avoided, will result in serious injury or death. WARNING – indicates a potentially hazardous situation which, if not avoided, could result in serious injury or death. CAUTION – indicates a possible hazardous situation which, if not avoided, could result in minor or moderate injury or damage to property. Notices on use Note – indicates useful and important information about the product or its use. Award elements Description of the markup elements used in this document: • A bullet point designates an action...

 Open the catalog to page 6
MEIKO TOPIC-7

The list shows the maximum possible symbols that can be used in conjunction with the washer-disinfector. The actual symbols applied vary depending on the design. The illustrations contained in this document are not necessarily true to the original or to scale. The illustration may deviate from the original, e.g. due to modifications to the product, but without diminishing the facts or comprehensibility.

 Open the catalog to page 7
MEIKO TOPIC-8

This section reproduces the content of the EC/EU Declaration of Conformity for the product. Contents that are already included in the instructions for use (e.g. intended use) are not listed again. The signed EC/EU Declaration of Conformity with serial number is enclosed with the product. We declare under our sole responsibility for this Declaration of Conformity that this product complies with Regulation (EU) 2017/745 on medical devices. Product designation Washer-disinfector (MDA 0317) Basic UDI-DI 4 050187 00222 Classification as per MDR (EU) 2017/745: Class IIa according to Annex VIII, Rule...

 Open the catalog to page 8
MEIKO TOPIC-9

Only use the washer-disinfector for emptying, cleaning and thermally disinfecting human waste containers, such as: • Bedpans, commode buckets and their covers • Urine bottles • Hospital containers, e.g. bowls, urine collecting containers • Suction bottles • Similar products as listed above, used for similar purposes. Nursing staff (older than 14 years) in clinics, nursing and/or rehabilitation facili ties who have been verifiably instructed in the use of the product. • Preferably utility rooms. The washer-disinfector is intended exclusively for commercial use. Any other use, modifications and...

 Open the catalog to page 9
MEIKO TOPIC-10

3.1.5 Determination of activities according to category of personnel

 Open the catalog to page 10
MEIKO TOPIC-11

Any use which is not detailed in the section on "Intended purpose" is contrary to List of foreseeable misuses: • Emptying of care utensils, although the holder is still equipped with freshly disinfected care utensils. • Inserting care utensils incorrectly. • Insertion of unsuitable utensils and objects (tableware). • Disinfection of objects for which a different method of preparation is stipulated e.g. instruments. • Heating objects or keeping them warm (hot water bottles, pre-packaged food, etc.) • Used for rubbish disposal e.g. garbage, nappies (diapers), disposable gloves, syringes etc.)....

 Open the catalog to page 11
MEIKO TOPIC-12

Safety information Only use the washer-disinfector according to instructions (see page 9). Only use the washer-disinfector in its original condition without independent changes and in a technically perfect condition. Electrical connection must be carried out in accordance with the locally applicable regulations (e.g. HD 60364-1/IEC 60364-1/VDE 0100-100) so the appliance can be connected to the mains supply in accordance with the regulations for installers. However, national regulations for installers may differ. The appliance is intended for permanent connection to the on-site power supply and...

 Open the catalog to page 12
MEIKO TOPIC-13

• The washer-disinfector does not generate targeted non-ionising radiation. For technical reasons, only the electrical appliances emit non-ionising radiation. In the immediate vicinity of the washer-disinfector, the influence of active implants (e.g. cardiac pacemakers, defibrillators) can be ruled out with a high degree of probability. • Do not place the washer-disinfector in a potentially explosive atmosphere or in areas subject to frost. • If the washer-disinfector is damaged or leaking, this may be dangerous and pose a safety hazard. Immediately decommission the washer-disinfector and inform...

 Open the catalog to page 13
MEIKO TOPIC-14

Electromagnetic compatibility MEIKO washer-disinfectors, built according to the standard CISPR 11:2009 Section 5, are class A appliances. The following applies for these appliances: Warning: This appliance may cause radio interference or may interfere with the operation of appliances in the vicinity. It may be necessary to take appropriate remedial action, such as realigning, rearranging or shielding. MEIKO washer-disinfectors with additional mains filter, built according to the standard CISPR 11:2009 Section 5, are class B appliances. No further actions are required for these appliances. What...

 Open the catalog to page 14

All MEIKO catalogs and technical brochures

  1. WasteStar CC

    2  Pages

  2. TopClean D

    4  Pages

  3. MEIKO TopLine

    68  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About ArchiExpo
ArchiExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. ArchiExpo is an entity of VirtualExpo Group.