LONG LASTING AND EFFICIENT SLOTTED DRAINAGE SYSTEM MADE OF CONCRETE ROBUST, DURABLE, COST-EFFICIENT, SAFE
Open the catalog to page 1With continuous or interrupted slot With and without fall Loading class up to F 900 according to DIN EN 1433 High quality concrete (grade C 45/55) Nominal width: 200 mm IMEACRET LINE 200 RELIABLE AND EFFICIENT MEACRET LINE 200 is a particularly robust drainage system made of high quality concrete (grade C45/55). It has been designed to withstand the highest loads and the most severe weather events. The drainage channel is ideal for installation in areas such as: > roads and highways > tunnels > industrial areas and ports > container terminals The MEACRET LINE is a type I (i) channel in accordance...
Open the catalog to page 2> Loading class up to E 600 / F 900 according to DIN EN 1433 > Can be paved directly > No moving parts: silent > Standard lengths: 1 m, 2 m, 3 m, 4 m; Intermediate lengths on demand > Flexible: Also available as a curb channel with bord heights of 7, 12, 15 and 18 cm BENEFITS FOR PLANNERS AND USER
Open the catalog to page 3IMEACRET LINE 200 INSTALLATION INSTRUCTION LOADING CLASS D 400 / E 600 installation EN 1433 ACCORDING TO DINinstruction MEACRET LINE 200 Loading class D 400 / E 600, according to DIN EN 1433 Joint sealant type N2 according to ZTV (elastic, compressible and stable in volume, NOT extruded) bituminous joint grouting *** Substrate compacted to at least 45 MPa Plan expansion joint in paving slab 1 Fahrbahnbeton Bituminöse Deckschicht *** Tragschicht gem. RStO 5 Erdreich 2 Bituminöse Tragschicht *Bewehrung und Expositionsklassen nach Angabe des verantwortlichen Planers. *** Entwässerung von hoch dynamisch...
Open the catalog to page 4Wenn von planerischer Seite keine anderen Vorgaben vorliegen,empfehlen wir die Einhaltung von Dehnfugen wie dargestellt THREAD JOINTS according to planner specifications according to planner specifications 1. Dehnfugen 2. Dehnfugen no other specifications from the planning side, we recommend to stick to the thread joint as shown in the drawing. If there are senkrecht zum Rinnenstrang in der Betonummantelung. MEA-Empfehlung für Zentral-Europa: Abstand der Dehnfugen quer zum Rinnenstrang 25m bis 30m. 1. Expansion joints In Ländern mitjoints perpendicular to the channel line in the concrete casing...
Open the catalog to page 5Sudetenstraße 1 D-86551 Aichach Business unit MEA Water Management