1. Catalogs
  2. MBCI
  3. Eco-ficient Insulated R Panel
video corpo
cad

Eco-ficient Insulated R Panel

Eco-ficient Insulated R Panel
1 / 108 PagesView full catalog

Eco-ficient Insulated R Panel

Product catalog summary
General Information: The Eco-ficient™ Series Insulated R Panel by MBCI is designed for specific building applications, emphasizing adherence to the latest specifications and guidelines available on the MBCI website. Thorough reading of the manual is crucial for compliance with warranties and safety regulations.
Important Notice: The manual is not suitable for cooler/freezer applications. Installers must follow OSHA regulations and inspect all panels and accessories before installation. Deviations from instructions require written approval from the manufacturer.
Installation Guidelines: Detailed guidelines include pre-order considerations, unloading, storage, and handling of panels, with specific procedures for manual and mechanical handling.
Wall Applications: Covers panel orientation, fastener patterns, substrate attachment, and preparatory requirements, including wall layout, panel sealant requirements, and panel joint engagement.
Roof Installation Sequence: Provides a step-by-step process for roof installation, including panel orientation, fastener placement, and preparatory requirements, with detailed instructions from the first to the last panel run.
Details: Includes specific details for ridge installation, eave trim, and skylight support, with diagrams and instructions for various installation scenarios.
Specifications: Panels are available in widths of 36" and thicknesses from 1½" to 6", designed for roof and wall applications with a maximum length of 40'. Made from Galvalume® substrate, they offer an R-value of up to 7.69 per inch and are suitable for roof slopes of ½:12 or greater.
Job Site Storage and Handling: Shipments should be checked against the shipping list upon delivery, and any damages noted. Panels must be handled carefully, ideally using a spreader bar for hoisting. Moisture inside bundles should be addressed by drying and restacking panels.
Application Checklist: Ensure proper substructure alignment to prevent panel distortion, regularly check panel alignment, and avoid contact with water runoff from lead, copper, or graphite.
Architect/Engineer Information: Panels do not provide diaphragm capabilities or purlin stability, so additional bracing may be necessary. Design must consider vapor drive and thermal efficiency, with proper vapor seals to prevent condensation.
Product Checklist: Includes a detailed checklist of fasteners and trim options, specifying dimensions and materials for various panel thicknesses.
Unloading Procedures: Detailed instructions for safely unloading materials using forklifts and cranes, emphasizing the importance of proper equipment and personnel to prevent damage and ensure safety.
Storage Recommendations: Advises on proper storage techniques to protect panel bundles from damage, water exposure, and chemical contamination.
Thermal Bowing: Exposure to the sun can cause panels to bow, making installation difficult. Correct by reversing the panel to allow even warming.
Handling Panels During Installation: Panels should be protected from impact damage during installation, using nylon slings or vacuum equipment for lifting.
Specifications and Safety Precautions: Outlines requirements for using vacuum heads to lift panels, emphasizing the need for special vacuum heads for minor ribs and warning against lifting under dynamic conditions.
Installation Procedures: Includes steps for verifying structural framing and bracing, ensuring steel framing is plumb, and checking substructure alignment.
Wall Panel Installation Overview: Provides detailed instructions for installing wall panels, including measurement, cutting, and installation to ensure symmetry and aesthetic appearance.
Framed Openings: All openings require a structural framed opening, with perimeter sealants installed before attaching wall panels.
Roof Panel Installation: Provides specifications and installation details for roof panels, emphasizing the use of male and female panel configurations and fastener patterns.
Safety and Compliance: Reminds installers to adhere to OSHA regulations and safe construction practices, with the manufacturer disclaiming responsibility for non-compliance issues.
Important Notes: Specifications are subject to change without notice, and users are advised to check the MBCI website for the most current information.
See more

Catalog excerpts

Eco-ficient Insulated R Panel-1

Metal Roof and Wall Systems Eco-ficient Series Technical/Installation Information

 Open the catalog to page 1
Eco-ficient Insulated R Panel-2

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ECO-FICIENT™ INSULATED R PANEL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO ENSURE APPROPRIATE WARRANTIES WILL BE ISSUED. IF THERE IS CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND DETAILS IN THIS MANUAL, PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE. THIS MANUAL IS NOT TO BE USED FOR COOLER/FREEZER APPLICATIONS. IT IS THE RESPONSIBILITY OF THE ERECTOR TO INSTALL THE ECO-FICIENT™ INSULATED R PANEL USING SAFE CONSTRUCTION PRACTICES THAT ARE IN COMPLIANCE WITH OSHA REGULATIONS....

 Open the catalog to page 2
Eco-ficient Insulated R Panel-3

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 TABLE OF CONTENTS GENERAL INFORMATION Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
Eco-ficient Insulated R Panel-4

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 TABLE OF CONTENTS ROOF INSTALLATION SEQUENCE Panel Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 4
Eco-ficient Insulated R Panel-5

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION INSTALLATION GUIDELINES I. Pre-Order A. Prior to ordering panels, all dimensions should be confirmed by...

 Open the catalog to page 5
Eco-ficient Insulated R Panel-6

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION GENERAL DESCRIPTION ECO-FICIENT™ INSULATED R PANEL ROOF OR WALL 36" 12" Exterior Surface 1¹⁄₄" 1¹⁄₂",...

 Open the catalog to page 6
Eco-ficient Insulated R Panel-7

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION ARCHITECT/ENGINEER INFORMATION MBCI’s Eco-ficient™ Insulated R Panel is available in a 36" panel width...

 Open the catalog to page 7
Eco-ficient Insulated R Panel-8

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION PRODUCT CHECKLIST Insulated R Panel 36" 12" Exterior Surface Tri-Bead Tape Sealer • 1" x 3/32" • or use...

 Open the catalog to page 8
Eco-ficient Insulated R Panel-9

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION PRODUCT CHECKLIST Wall Fasteners - Face Fasten-Panel Flat • " Hex Washer Head ⅜ w/ ⅝" O.D. Washer • Requires...

 Open the catalog to page 9
Eco-ficient Insulated R Panel-10

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION PRODUCT CHECKLIST Inside Corner Trim-Flat • nterior surface only I • rim is embossed as T standard • rder...

 Open the catalog to page 10
Eco-ficient Insulated R Panel-11

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Mattoon, IL 888/885-0468 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Insulated R Panel GENERAL INFORMATION PRODUCT CHECKLIST Jamb Trim • rim is smooth as standard T • rder trim length as O required - Maximum trim...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.