1. Catalogs
  2. MBCI
  3. Eco-ficient Classic
video corpo
cad

Eco-ficient Classic

Eco-ficient Classic
1 / 76 PagesView full catalog

Eco-ficient Classic

Product catalog summary
Overview: The Eco-ficient™ Series by MBCI offers insulated wall panels with hidden fasteners, designed for energy efficiency and architectural appeal. These panels are available in five profiles and various thicknesses, tailored to specific project needs.
Specifications: Panels can be custom ordered in lengths up to 32' or 40'. They are heavier than single skin panels, requiring specific handling and installation techniques. The panels are attached using concealed clips to prevent thermal bridging.
Installation Guidelines: It is crucial to read the manual thoroughly before installation. The manual details the necessary steps for unloading, storing, and staging the panels. Proper handling is essential to avoid damage and ensure warranty validity.
Design Considerations: The panels require additional insulation at corners and parapets to maintain thermal efficiency. Vapor barriers must be carefully designed to prevent condensation. Oil canning, a potential issue with wide flat surfaces, can be minimized through careful design and installation.
Limitations: The panels do not provide diaphragm capabilities or girt stability, necessitating additional bracing. They are not intended for cooler/freezer applications without consulting MBCI.
Recommendations: For environments requiring frequent washdowns, consider embossed metal skins to reduce waviness. Consult MBCI for projects involving long panel lengths, dark colors, or specific structural requirements.
Contact Information: For the latest specifications and support, visit www.mbci.com or contact local MBCI representatives.
General Description: The document provides technical specifications for the Eco-ficient™ Series wall systems, which include various panel types such as Grand VW, Royal, Summit, Classic, and Vintage. These panels are designed for vertical applications and feature a stucco embossed finish on both the exterior and interior surfaces.
Specifications:
  • Panel Substrate: Standard Galvalume® with other substrates available upon inquiry.
  • Exterior Panel Finish: Stucco Embossed, with variations like striations, flutes, and Aztec embossing depending on the model.
  • Interior Panel Finish: Stucco Embossed with Mesa profile.
  • Panel Gauges: Exterior gauges range from 22 to 26, while interior gauges are typically 26, with other options available upon inquiry.
  • Coatings: Exterior coatings include Signature® 200 and 300, while the standard interior coating is USDA White.
  • Panel Thickness: Available in 2", 2½", 3", and 4" thicknesses, with some models offering up to 6".
  • R-Value: Approximately 7.69 per inch of thickness.
  • Coverage Widths: Panels are available in 36" and 42" widths.
  • Panel Attachment: Concealed clips are used for panel attachment.
Procedures and Recommendations:
  • For wind load information, refer to the MBCI website.
  • Minimum quantities may be required for certain color options as per the Eco-ficient™ color chart.
  • Specifications are subject to change without notice, and current information should be verified on the MBCI website.
Product Checklist: The document includes a detailed checklist of various trims, fasteners, and clips used in the installation of the panels. These components are available in different sizes and materials, including galvanized and stainless steel options.
Contact Information: The document lists contact numbers for various locations across the United States for further inquiries and support.
General Information: The document provides detailed instructions for handling and installing the Eco-ficient™ Series panels. It includes contact information for various locations across the United States and emphasizes that the information is subject to change, advising users to check the website for the most current details.
Unloading Procedures: Before materials arrive, contractors must plan the unloading process, including determining the necessary equipment and personnel. Upon receipt, materials should be checked against the packing list for any shortages or damages. The maximum weight for any bundle is 7,500 lbs, and bundles should be lifted one at a time using appropriate equipment like forklifts or cranes. Specific guidelines are provided for using forklifts and cranes, emphasizing safety and proper handling to prevent damage.
Storage Guidelines: Panels are shipped in stretch-wrapped bundles and must be stored properly to avoid damage. This includes keeping them off the ground, allowing for ventilation, and protecting them from water and chemical exposure. Opened bundles should be covered and secured to prevent damage from weather or wind.
Staging Instructions: Bundles are marked with numbers and accompanied by reports detailing their contents. Proper staging involves positioning bundles close to their installation area while allowing space for equipment and workers. Special considerations are needed for tall walls and interior partitions to ensure efficient installation.
Preparatory Requirements: Before installation, verify that all structural framing and bracing are in place and properly aligned. The document specifies tolerances for substructure alignment to prevent issues like oil canning. It also notes that additional bracing may be required to meet specific specifications.
Overview: This document provides detailed instructions and guidelines for the installation of Eco-ficient™ Series panels, focusing on base assembly, preparatory requirements, wall layout, and handling during installation. It includes specifications for sealants, fasteners, and panel cutting, as well as recommendations for ensuring structural integrity and aesthetic appearance.
Base Assembly: The document outlines the importance of proper base assembly to prevent panel bowing and oil canning. It specifies the use of urethane and non-skinning butyl sealants for sealing base flashing and joints. The base angle must be attached to the foundation with specified fasteners, and additional support may be required when there is no sheeting notch.
Preparatory Requirements: Before installing wall panels, ensure all interior trims are in place. Continuous sealant beads are necessary for vapor seals, and any structural gaps should be covered with joint flashing. The document emphasizes the use of non-skinning butyl sealant and optional foam tape for sealing.
Panel Cutting and Installation: Panels should be cut using a circular saw with a metal cutting blade to avoid damaging the Galvalume® coating. Proper support during cutting is crucial to prevent damage. Inspect panels for damage before installation, and set aside any damaged panels for potential use in less visible areas.
Wall Layout: For a symmetrical and aesthetically pleasing wall, corner panels should be of equal dimension. The document provides a method for calculating panel widths to achieve this. It also describes different corner cutting techniques, including beveled, lapped, and interlocking corners, and recommends using expanding foam or blanket insulation in voids.
Handling Panels During Installation: Proper handling is critical to avoid damage. Panels should be lifted from the bottom face only and protected from rough surfaces. The document advises on manual and crane-assisted panel handling, emphasizing the need for adequate workforce and safe lifting equipment.
Conclusion: The document provides comprehensive guidelines for the installation of Eco-ficient™ Series panels, focusing on maintaining structural integrity and aesthetic quality. Adherence to these guidelines is essential for successful installation.
Handling Panels During Installation: Panels are lifted to a vertical position and secured to the structure. To prevent damage, a bearing pad should be placed between panels. Ensure panels can be lifted without excessive bending or buckling. Edge lifting may be required for longer panels.
Setting Panels with a Crane: Edge lifting involves rolling the panel onto its edge before lifting. A bearing pad protects the panel edge, and sufficient workers are needed to stabilize the panel to prevent twisting. Caution is advised as wind and jerky movements can exceed equipment capacity.
Setting Panels with a Vacuum Lift: Vacuum lifts avoid damage by not requiring holes or clamps. Properly sized vacuum units minimize bending or buckling. Contractors must ensure equipment capacity and suitability for panel surfaces. Caution is advised against wind and jerky movements.
Panel Sealant Requirements: Field-applied sealant may be required depending on project specifications. Factory-applied mastic should be inspected and repaired if necessary. Sealant must be applied continuously in specified grooves, ensuring continuity at intersections to prevent condensation.
Panel Joint Engagement: Proper engagement is crucial for performance and appearance. Joint gaps should not exceed ⅛". Clips are used for attachment, and sealant application must follow project drawings. Vapor sealant locations should be determined by an engineer.
Base and Intermediate Supports: Base trim must be sealed to the concrete, and perimeter sealant applied. Panels are fastened to the base and intermediate supports using clips and fasteners as specified in construction drawings.
Eave/Rake and Corners: Panels are attached at eave and rake with clips or face fastened as specified. Corners are field cut for symmetry, and interior corner flashing and perimeter sealant must be applied before installation.
Overview: The document provides detailed installation instructions for the Eco-ficient™ Series panels, focusing on the use of non-skinning butyl sealants and various trim components for framed and door openings. It includes specifications for sealants, fasteners, and panel clips, as well as procedures for installing wall panels and trims.
Specifications:
  • Sealants: Non-skinning butyl sealant is used extensively, with optional foam tape for additional sealing. Urethane sealant is also specified for certain applications.
  • Fasteners: Flat head thru-panel fasteners are used at 24" on center, while pop rivets or lap tek self-drillers are used at 12" on center for sill trim.
  • Panel Clips: Wall Panel Clip HW-2320 is used for securing panels.
Installation Procedures:
  • Framed Openings: Install wall panels with clips at all horizontal structural points. Fasten panels to jambs with self-drilling or self-tapping fasteners.
  • Flat Trim Installation: Cut and notch head and sill trims, apply tape sealant around the perimeter, and fasten trims to wall panels.
  • Door Openings: Use flat jamb trim, attach panels from the back side, and apply perimeter sealants. Pre-drill jambs for fastener installation.
Recommendations:
  • Ensure panels are aligned and plumb before installation.
  • Use a 6' level to check panel alignment.
  • Avoid forcing panels to conform to out-of-plane structural members to prevent oil canning.
General Information: Contact information for various locations is provided for further assistance. The document notes that specifications are subject to change and advises checking the website for the most current information.
Critical Information:
  • Proper alignment and sealing are crucial for effective installation.
  • Use specified fasteners and sealants to ensure structural integrity and weatherproofing.
  • Follow detailed instructions for cutting and installing trims to maintain panel performance.
Overview: The document provides detailed installation instructions and quality control measures for the Eco-ficient™ Series panels, focusing on the use of non-skinning butyl sealants and various fastening techniques. It includes specifications for setting panels, quality checks, and detailed corner and joint treatments.
Specifications: The panels require non-skinning butyl sealant for both interior and exterior applications, with optional foam tape. The document specifies the use of HW-2320 wall panel clips and concrete fasteners for secure attachment. A 1" gap must be maintained during installation to prevent sealant displacement.
Installation Procedures: The installation process involves positioning the panel on the base assembly, ensuring the edge clears the side lap of the previously installed panel. The panel is then pushed to engage the tongue-and-groove side lap. Clips are installed at all structural locations once the panel is fully engaged.
Quality Control: Panels must be checked for damage before installation. Key checks include ensuring no ripples, dents, or scratches are present, and that the tongue-and-groove side lap is properly engaged. Fasteners should not overdrive more than 1/16" to avoid panel edge damage.
Details and Recommendations: The document provides detailed diagrams for base, corner, and joint treatments, emphasizing the continuous application of non-skinning butyl sealant. It also outlines the use of various fasteners and clips to ensure structural integrity and proper panel alignment.
Contact Information: The document lists contact numbers for various locations across the United States for further assistance or inquiries.
See more

Catalog excerpts

Eco-ficient Classic-1

Eco-ficient™ Series Hidden Fastener Insulated Wall Panels Technical/Installation Information

 Open the catalog to page 1
Eco-ficient Classic-2

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE ECO-FICIENT™ INSULATED METAL PANEL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO ENSURE APPROPRIATE WARRANTIES WILL BE ISSUED. IF THERE IS CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND DETAILS IN THIS MANUAL, PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE. ©2010 MBCI, a division of NCI Group, Inc. All Rights Reserved. 08-2010/7.5M Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort...

 Open the catalog to page 2
Eco-ficient Classic-3

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 TABLE OF CONTENTS WALL SYSTEM Architect/Engineer Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
Eco-ficient Classic-4

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 WALL SYSTEM Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series ARCHITECT/ENGINEER INFORMATION MBCI’s Eco-ficient™ Insulated Wall Panels are available in five distinct profiles, which in turn are available in a variety...

 Open the catalog to page 4
Eco-ficient Classic-5

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 WALL SYSTEM Eco-ficient™ Series GENERAL DESCRIPTION ECO-FICIENT™ GRAND VW (vertical application) 36" Exterior Surface 2", 2 ½", 3" or 4" Coverage Width – 36" Panel Attachment – Concealed...

 Open the catalog to page 5
Eco-ficient Classic-6

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 WALL SYSTEM Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series GENERAL DESCRIPTION ECO-FICIENT™ ROYAL 36" and 42" Exterior Surface 2", 2 ½", 3" or 4" Coverage Widths – 36" and 42" Panel Attachment – Concealed Clips Panel...

 Open the catalog to page 6
Eco-ficient Classic-7

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 WALL SYSTEM Eco-ficient™ Series GENERAL DESCRIPTION ECO-FICIENT™ SUMMIT 36" and 42" Exterior Surface 2", 2 ½", 3" or 4" Coverage Widths – 36" and 42" Panel Attachment – Concealed Clips...

 Open the catalog to page 7
Eco-ficient Classic-8

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 WALL SYSTEM Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series GENERAL DESCRIPTION ECO-FICIENT™ CLASSIC 42” 4.2” 4.2” Exterior Surface Coverage Width – 42" Panel Attachment – Concealed Clips Panel Substrate – Galvalume®...

 Open the catalog to page 8
Eco-ficient Classic-9

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 WALL SYSTEM Eco-ficient™ Series GENERAL DESCRIPTION ECO-FICIENT™ VINTAGE 36" and 42" Exterior Surface 2", 2 ½", 3" or 4" Coverage Width – 36" and 42" Panel Attachment – Concealed Clips...

 Open the catalog to page 9
Eco-ficient Classic-10

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 GENERAL INFORMATION GENERAL INFORMATION Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series Eco-ficient™ Series PRODUCT CHECKLIST Wall Panel Clip • 4" length • 4 gauge Galvanized 1 Friction Clip • 2¾" length • 5 gauge...

 Open the catalog to page 10
Eco-ficient Classic-11

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Eco-ficient™ Series GENERAL INFORMATION PRODUCT CHECKLIST Inside Corner Trim, Offset 1" 3" • 10½" girth • 2", 2½", 3" and 4" thick panels • 26, 24 and 22 gauge • 10¼" girth • ", 2½", 3"...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.