Important Notice: This document provides essential guidelines for installing the Designer™ Series Wall System, emphasizing adherence to MBCI details for warranty validity. It advises inspecting all panels and accessories before installation and states that erection drawings take precedence over the manual in case of discrepancies.
General Information: The document stresses consulting MBCI’s warranties for performance specifications and product limitations. It highlights the need for design professionals to reference the North American Specification for Cold-Formed Steel Structural Members and applicable building codes.
Installation Guidelines:
  • Pre-Order: Confirm dimensions with field measurements before ordering panels.
  • Jobsite Storage and Handling: Inspect shipments, note damages, and ensure proper handling to prevent moisture accumulation.
  • Application Checklist: Ensure substructure alignment, maintain panel cleanliness, and avoid contact with certain materials.
Specifications: Detailed specifications for metal wall systems are provided, including applicable standards (SMACNA, AISC, AISI, ASTM), manufacturer and contractor qualifications, and submittal requirements for shop drawings and samples.
Design: Designer™ Series panels are available in 12" Flat and 16" Fluted profiles. Proper alignment of wall girts is crucial to prevent oil canning, and heavier gauges are recommended to minimize this effect. The panels do not provide diaphragm capabilities in new constructions.
Product Selection: Panels are available in Galvalume Plus® and Signature® finishes, with specific gauge options and color availability.
Specifications and Warranties: The document outlines a 20-year warranty against structural failure and corrosion, and a 25-year warranty for paint finish defects. The metal wall system must be fabricated in a factory environment with fixed-base roll forming equipment.
Installation Contractor Qualifications: Installers must meet specific qualifications and provide references from previous projects to ensure satisfactory performance.
Product Delivery, Storage, and Handling: Metal wall systems should be delivered properly packaged, handled with care to prevent damage, and stored above ground with proper ventilation to avoid condensation.
Materials and Fabrication: Options for metal roof system profiles, wall system styles, gauges, substrates, textures, finishes, and colors are specified. The fabrication process includes tension leveling and roll forming.
Execution and Installation: Installation must ensure the system is weathertight and free from distortions, following manufacturer instructions and shop drawings. Panels should be installed plumb, level, and straight.
Cleaning and Protection: Excess materials should be disposed of, and the work area cleaned according to manufacturer recommendations. The installed system should be protected until final acceptance, with any damage repaired.
Design and Panel Attachment: Detailed instructions for panel attachment, fastener locations, and door framing details are included, emphasizing proper installation techniques to ensure structural integrity.
Disclaimer: MBCI disclaims any warranty for products manufactured by optional manufacturers, emphasizing that specifications are subject to change without notice.
Door Framing Details: Detailed instructions for door framing include the installation of cap trim, base angle, and fasteners, specifying the use of insulation and notes on cutting and notching tabs for header and jamb caps.
Window Framing Details: Instructions for window framing include typical header/sill and jamb details, emphasizing holding back insulation for clarity and providing specific fastener spacing.
Jamb Cleat Installation: Details the installation of jamb cleats, including notching for header cleats and attaching them with specified fasteners, highlighting the importance of continuing the cleat to the bottom of the wall.
Header Cleat Installation: Instructions include notching to fit into the jamb cleat and attaching with fasteners, specifying fastener spacing and emphasizing proper alignment.
Spacer Zee Installation: Describes the installation of support zee, including fastener placement and the use of panel drop for high flute finishing.
Panel Installation: Instructions include stitching panel side laps with fasteners and holding back insulation from the base trim.
Cap Trim Installation: Provides detailed steps for installing cap trim, including cutting and notching tabs for header and sill trims, and attaching them with fasteners.
Corner Details: Includes typical inside and outside corner details, specifying the use of fasteners and trims for proper attachment and finishing.
Contact Information: Lists contact details for various locations across the United States, providing phone numbers and addresses for each site.
See more

Catalog excerpts

Designer Series-1

Metal Roof and Wall Systems Designer™ Series Technical/Product Information

 Open the catalog to page 1
Designer Series-2

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Designer™ Series WALL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE WARRANTIES WILL BE ISSUED. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY MBCI IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE OR HAS BEEN DAMAGED DURING SHIPMENT. IF THERE IS A CONFLICT BETWEEN APPROVED ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND THE DETAILS IN THIS MANUAL, THE PROJECT ERECTION DRAWINGS...

 Open the catalog to page 2
Designer Series-3

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 TABLE OF CONTENTS ROOFING SYSTEM Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-2 General Description.....

 Open the catalog to page 3
Designer Series-4

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 GENERAL INFORMATION Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Designer™ Series INSTALLATION GUIDELINES I. Pre-Order A. Prior to ordering panels, all dimensions should be confirmed by field measurements. II. Jobsite Storage and...

 Open the catalog to page 4
Designer Series-5

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 WALL SYSTEM Designer™ Series GENERAL DESCRIPTION 12" FLAT 12” 1³⁄₄” Coverage Width - 12" Panel Attachment - See page DS-11 Panel Substrate - Galvalume Plus® Panel Finish - Smooth or Embossed...

 Open the catalog to page 5
Designer Series-6

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 WALL SYSTEM Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Designer™ Series GENERAL DESCRIPTION 16" FLUTED 16” 1³⁄₄” ³⁄₈” Coverage Width - 16" Panel Attachment - See page DS-11 Panel Substrate - Galvalume Plus® Panel Finish - Smooth...

 Open the catalog to page 6
Designer Series-7

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Designer™ Series Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 WALL SYSTEM ARCHITECT/ENGINEER INFORMATION 1. esigner™ Series is a concealed fastener wall panel designed to be used as either a retrofit wall D panel or in new construction....

 Open the catalog to page 7
Designer Series-8

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 SPECIFICATIONS Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Designer™ Series Metal Wall Systems Specifier: Notation (#) means that text following is a specifier's note or sample. PART 1 - GENERAL 1.01 DESCRIPTION # Specifier: Do not...

 Open the catalog to page 8
Designer Series-9

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 SPECIFICATIONS Designer™ Series (25) years for wall panels (premium thermoset silicone polyester) or twenty-five (25) years for wall panels (premium fluorocarbon coating produced with Kynar...

 Open the catalog to page 9
Designer Series-10

Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 SPECIFICATIONS Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 Designer™ Series 3.03 CLEANING, PROTECTION A. Dispose of excess materials and remove debris from site. B. Clean work in accordance with manufacturer's recommendations. C....

 Open the catalog to page 10
Designer Series-11

Jackson, MS 800/622-4136 Lubbock, TX 800/758-6224 Memphis, TN 800/206-6224 Oklahoma City, OK 800/597-6224 Omaha, NE 800/458-6224 Phoenix, AZ 888/533-6224 Houston, TX 877/713-6224 Adel, GA 888/446-6224 Atlanta, GA 877/512-6224 Atwater, CA 800/829-9324 Dallas, TX 800/653-6224 Indianapolis, IN 800/735-6224 Richmond, VA 800/729-6224 Rome, NY 800/559-6224 Salt Lake City, UT 800/874-2404 San Antonio, TX 800/598-6224 GENERAL INFORMATION Designer™ Series PRODUCT CHECKLIST Designer™ Series 16" Fluted Panel Designer™ Series 12" Flat Panel 16” 12” 1³⁄₄” 1³⁄₄” ³⁄₈” □ Outside Corner Inside Corner 3¹⁄₂” □...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.