Catalog excerpts
5V Crimp Design/Installation Information
Open the catalog to page 1IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE 5V CRIMP PANEL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE WARRANTIES WILL BE ISSUED. ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY MBCI IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE, SPECIFICATION OR HAS BEEN DAMAGED DURING SHIPMENT. IF THERE IS A CONFLICT BETWEEN PROJECT ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND DETAILS IN THIS MANUAL, PROJECT ERECTION...
Open the catalog to page 2Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 5V CRIMP Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 PRODUCT INFORMATION TABLE OF CONTENTS A. B. C. D. E. F. G. Architect/Engineer Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2...
Open the catalog to page 3Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 PRODUCT INFORMATION Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 5V CRIMP ARCHITECT/ENGINEER INFORMATION 1. Minimum recommended slope is 3:12. For slopes less than 3:12, call MBCI. 2. Use a properly aligned and uniform substructure to avoid panel...
Open the catalog to page 4Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 PRODUCT INFORMATION 5V CRIMP GENERAL DESCRIPTION Coverage Width - 24" Minimum Slope - 3:12 Panel Attachment - Wood screws Panel Substrate - Galvalume Plus ® Gauges - 29 or 26 Finishes - Smooth or embossed ®...
Open the catalog to page 5Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 PRODUCT INFORMATION Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 5V CRIMP UL 90 Requirements 5V Crimp Construction # 453 1. Metal Panels (26 gauge) – 24" wide, continuous over two or more spans. 2. Fastener spacing along the length of the panel is 3...
Open the catalog to page 6Metal Roof and Wall Systems * Fy is 80-ksi reduced to 60-ksi in accordance with the 2001 edition of the North American Specification For Design Of Cold-Formed Steel Structural Members - A2.3.2. Steel Structural Members. 4. Maxo is allowable bending moment. 5. All values are for one foot of panel width. 29 Gauge (Fy = 60 KSI) ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 26 Gauge (Fy = 60KSI) ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 1) Allowable loads are based on uniform span lengths and Fy = 60-ksi. 2) LIVE LOAD is limited by bending, shear, combined shear & bending and web...
Open the catalog to page 7Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 PRODUCT INFORMATION Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 5V CRIMP PRODUCT CHECKLIST Panel Valley Ridge/Hip AG-237 Rake Trim AG-202 Specify Roof Pitch Drip Edge AG-250 AG-279 Outside Closure HW-452 Continuous Cleat HW-450 HW-504 Fastener #9 10 x...
Open the catalog to page 8Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 5V CRIMP Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 PRODUCT INFORMATION FASTENER PATTERNS EFFECTIVE NOVEMBER 1, 2011 SEE www.mbci.com FOR CURRENT INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE V-7
Open the catalog to page 9Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 PRODUCT INFORMATION Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 5V CRIMP TYPICAL DETAILS RIDGE NOTES: 1. Stop panels 2" from center line of ridge. 2. Install first row of fasteners across panel to substrate 1'-0" down from bottom edge of ridge trim and...
Open the catalog to page 10Houston, TX 877-713-6224 Adel, GA 888-446-6224 Atlanta, GA 877-512-6224 Atwater, CA 800-829-9324 Dallas, TX 800-653-6224 5V CRIMP Indianapolis, IN 800-735-6224 Lubbock, TX 800-758-6224 Memphis, TN 800-206-6224 Oklahoma City, OK 800-597-6224 Omaha, NE 800-458-6224 Phoenix, AZ 888-533-6224 Richmond, VA 800-729-6224 Rome, NY 800-559-6224 Salt Lake City, UT 800-874-2404 San Antonio, TX 800-598-6224 PRODUCT INFORMATION TYPICAL DETAILS ALTERNATE RIDGE/HIP NOTES: 1. Stop panels 2" from center line of ridge. 2. Install first row of fasteners across panel to substrate 1'-0" down from bottom edge of...
Open the catalog to page 11All MBCI catalogs and technical brochures
-
Agricultural Catalog 4-2020
45 Pages
-
Commercial Industrial Catalog
76 Pages
-
Architectural Catalog 1-7-2021
69 Pages
-
IMP Catalog 4-1-2020
96 Pages
-
SSR Catalog 4-1-2020
79 Pages
-
PBR / Stormproof Slick
2 Pages
-
Fire Resistant
4 Pages
-
HPCI Barrier
4 Pages
-
Retro-R Brochure
4 Pages
-
Weathertightness Warranties
8 Pages
-
Solar Solutions Brochure
6 Pages
-
Retrofit Brochure
8 Pages
-
Eco-ficient Technical
24 Pages
-
Eco-ficient
20 Pages
-
Certified Installer Brochure
4 Pages
-
Architectural
32 Pages
Archived catalogs
-
Eco-ficient Insulated R Panel
108 Pages
-
Eco-ficient Insulated BattenLok
62 Pages
-
Eco-ficient Grand V
76 Pages
-
Eco-ficient Grand H
48 Pages
-
Eco-ficient Classic
76 Pages
-
Double-Lok over R
28 Pages
-
Double-Lok
94 Pages
-
Designer Series
32 Pages
-
Curved BattenLok
60 Pages
-
Craftsman Series
76 Pages
-
BattenLok HS
102 Pages
-
MBCI
8 Pages
-
Standing Seam Roof
8 Pages
-
NuRoof
4 Pages
-
Eco-ficient
4 Pages
-
Curvef Panel Systems
4 Pages