video corpo cad

Wood Ultimate Double Hung Bow and Bay
18Pages

{{requestButtons}}

Catalog excerpts

Wood Ultimate Double Hung Bow and Bay - 2

19972255 Marvin Architectural Detail Manual

Open the catalog to page 2
Wood Ultimate Double Hung Bow and Bay - 3

Wood Ultimate Double Hung Bow and Bay Unit Features Wood Ultimate Double Hung - WUDHBB  6 degree angle on Bows  Laminated Pine wood or optional Douglas Fir head and seat boards installed  Installation brackets are available in lieu of nailing fin  Optional retro fit bay square jamb return for WUDHBB Information concerning Daylight Opening, Egress Opening, and Vent Opening will be determined based on the individual components of the Bow or Bay. Bay standard operation as viewed from exterior. Bow standard operation as viewed from exterior. NOTE: Also see Wood Ultimate Double Hung...

Open the catalog to page 3
Wood Ultimate Double Hung Bow and Bay - 4

Wood Ultimate Double Hung Bow and Bay Min and Max Sizing and Projection for Bows and Bays Rough Opening Configuration Projection Depth Configuration

Open the catalog to page 4
Wood Ultimate Double Hung Bow and Bay - 5

Wood Ultimate Double Hung Bow and Bay Standard Heights for Bows and Bays Call Number Height Rough Opening Height (w/ head & seat boards) Frame Size Height (w/ head & seat boards) Rough Opening Masonry Opening 19972255 Marvin Architectural Detail Manual

Open the catalog to page 5
Wood Ultimate Double Hung Bow and Bay - 6

Wood Ultimate Double Hung Bow and Bay Measurement Conversions Unit Measurements Width From Rough Opening - 30° Bay Masonry Opening Masonry Opening Masonry Opening Rough Opening - 4W Bow Masonry Opening Rough Opening (w/ head and seat boards) Rough Opening - 5W Bow Masonry Opening Rough Opening (w/ head and seat boards) Rough Opening - 6W Bow Masonry Opening Rough Opening (w/ head and seat boards) Rough Opening (w/ head and seat boards) Rough Opening (w/ head and seat boards) Rough Opening (w/ head and seat boards) Rough Opening (w/ head and seat boards) Rough Opening - 45° Bay Masonry...

Open the catalog to page 6
Wood Ultimate Double Hung Bow and Bay - 7

Wood Ultimate Double Hung Bow and Bay Bow Rough Opening and Projection - 3 Wide, 4 Wide, 5 Wide, 6 Wide Bow Call Number (Width) 16 Number Wide 19972255 Marvin Architectural Detail Manual

Open the catalog to page 7
Wood Ultimate Double Hung Bow and Bay - 8

Wood Ultimate Double Hung Bow and Bay Section Details: Bow Rough Opening Outside Radius Masonry Opening 19972255 Marvin Architectural Detail Manual

Open the catalog to page 8
Wood Ultimate Double Hung Bow and Bay - 9

Wood Ultimate Double Hung Bow and Bay Standard Width Call Number: 30° Bay Marvin Architectural Detail Manual

Open the catalog to page 9
Wood Ultimate Double Hung Bow and Bay - 10

Wood Ultimate Double Hung Bow and Bay Section Detail: 30° Bay Not to Scale Operating Center Unit Rough Opening 30° Rough Opening to Projection Corner Rough Opening to Projection Corner Masonry Opening Picture Center Unit Rough Opening 30° Rough Opening to Projection Corner Rough Opening to Projection Corner Masonry Opening Flat Casing Brick Mould Casing Rough Opening Masonry Opening NOTE: 30° WUDH Bay with optional 3 1/2 (89) Flat Casing. Bow or bay assemblies with wood flat casing use enclosed profile casing. For 30° bay masonry opening widths using clad flat casing, add 6 1/4” (159) to...

Open the catalog to page 10
Wood Ultimate Double Hung Bow and Bay - 11

Wood Ultimate Double Hung Bow and Bay Rough Opening and Projection Calculations: 30° Bay Marvin Architectural Detail Manual

Open the catalog to page 11
Wood Ultimate Double Hung Bow and Bay - 12

Wood Ultimate Double Hung Bow and Bay Standard Width Call Number: 45° Bay Call Number (Width) 19972255 Marvin Architectural Detail Manual

Open the catalog to page 12
Wood Ultimate Double Hung Bow and Bay - 13

Wood Ultimate Double Hung Bow and Bay Section Detail: 45° Bay Not to Scale Operating Center Unit Rough Opening Exterior of Sheathing 45° Rough Opening to Projection Corner Rough Opening to Projection Corner Masonry Opening Picture Center Unit Rough Opening Exterior of Sheathing 45° Rough Opening to Projection Corner Rough Opening to Projection Corner Masonry Opening Flat Casing Brick Mould Casing Rough Opening Rough Opening Optional: fill with insulation Masonry Opening Masonry Opening NOTE: 30° WUDH Bay with optional 3 1/2 (89) Flat Casing. Bow or bay assemblies with wood flat casing use...

Open the catalog to page 13
Wood Ultimate Double Hung Bow and Bay - 14

Wood Ultimate Double Hung Bow and Bay Rough Opening and Projection Calculations: 45° Bay Marvin Architectural Detail Manual

Open the catalog to page 14
Wood Ultimate Double Hung Bow and Bay - 15

Wood Ultimate Double Hung Bow and Bay Standard Width Call Number: 60° Bay Call Number (Width) 19972255 Marvin Architectural Detail Manual

Open the catalog to page 15
Wood Ultimate Double Hung Bow and Bay - 16

Wood Ultimate Double Hung Bow and Bay Section Detail: 60° Bay Not to Scale Operating Center Unit Rough Opening 60° Rough Opening to Projection Corner Rough Opening to Projection Corner Masonry Opening Picture Center Unit Rough Opening Rough Opening to Projection Corner Projection Corner to Projection Corner Masonry Opening Flat Casing Brick Mould Casing Rough Opening Rough Opening Masonry Opening Masonry Opening NOTE: 30° WUDH Bay with optional 3 1/2 (89) Flat Casing. Bow or bay assemblies with wood flat casing use enclosed profile casing. For 30° bay masonry opening widths using clad flat...

Open the catalog to page 16
Wood Ultimate Double Hung Bow and Bay - 17

Wood Ultimate Double Hung Bow and Bay Rough Opening and Projection Calculations: 60° Bay Wood Ultimate Double Hung Bay 60-Degree Projection (OM width of flanker unit PLUS 3.947) x 0.866 Rough Opening Width Projection x .577 + 1.018 + Center Om Width Masonry Opening Unit Add 6.861" (174) to Rough Opening width Rough Opening Height (with Head and Seat boards) Masonry Opening Height (with Head and Seat boards) OM height on center unit(s) PLUS 2 9/32" (58) Rough Opening height ADD 3/8" (10) 19972255 Marvin Architectural Detail Manual

Open the catalog to page 17
Wood Ultimate Double Hung Bow and Bay - 18

Wood Ultimate Double Hung Bow and Bay Section Detail: 90° Bay Scale: 3" = 1’ 0" 90° Bay - WUDHBB Masonry Opening Rough Opening Flanker Frame Size Center Unit Frame Size 19972255 Marvin Architectural Detail Manua