Underground

Underground
1 / 27 PagesView full catalog

Underground

Product catalog summary
Overview: This document serves as a comprehensive guide on Marley Underground Drainage Systems, focusing on the design and installation of drainage components for various applications such as household, sewer, and highway drainage. It covers both solid wall and structured wall systems.
Range Overview: Marley offers solid wall systems with diameters of 110mm and 160mm for adoptable and private applications, and the Quantum structured wall range in 150mm, 225mm, and 300mm diameters for sewer and highway applications.
Product Specifications: Detailed specifications are provided for components like pipes, couplings, bends, inspection chambers, and gullies, including dimensions, materials, and compliance with standards such as BS EN 1401 and BBA certifications.
Design and Installation: The guide covers pipe laying procedures, highway drainage, filter drains, and inspection chambers, emphasizing compliance with building regulations and standards for effective drainage solutions.
Inspection Chambers and Manholes: Various types of inspection chambers and manholes are detailed, including specifications for shallow, deep, and adoptable chambers, and their applications.
Safety and Standards: Safety guidelines and compliance with standards like BS 1401 and BS 4660 are highlighted to ensure safe installation and operation.
Key Features and Benefits: Marley systems are noted for flexibility, chemical resistance, and hydraulic performance, with benefits such as fewer joints to reduce leaks and blockages, and high-quality materials for durability.
Design and Statutory Requirements: Compliance with standards such as BS EN 752 and BS EN 2015, and The Building Regulations is required. Guidelines on access for testing and debris removal are provided.
Gradients and Physical Characteristics: Specific gradients for self-cleansing in foul water drainage systems are detailed, along with physical characteristics of pipes.
Pipe Strength and Perforation: Minimum ring stiffness for pipe types and sizes is specified, ensuring durability and compliance with transport specifications.
Pipe Laying and Bedding: Recommendations for pipe laying, bedding, and backfill materials are based on BS 5955: Part 6 and BS EN 1610, emphasizing proper bedding and backfill for system integrity.
Specifications: Trench excavation and pipe laying specifications emphasize using suitable materials as per BS 5955: Part 6: Appendix A, with guidelines for trench width and support.
Procedures: Detailed procedures for using granular material for bedding and surrounding PVCu drains and sewers are provided, with grading requirements in compliance with BS EN 1610.
Norms and Standards: References to standards like BS EN 1610 and DTp Advice Note HA 40/89 are included for trench and bedding specifications.
Recommendations: Recommendations include using concrete slabs for shallow domestic drains under roads and ensuring proper protection for pipes under private roads and solid ground floors.
Key Data from Tables and Diagrams: Tables specify nominal pipe sizes and granular material sizes, with diagrams illustrating trench and bedding configurations.
Critical Information: Minimum trench width should be pipe diameter plus 300mm, with specific cover requirements for drains and inspection chambers.
Best Practices: Emphasis is placed on using suitable bedding and backfill materials, ensuring proper trench support, and following specified standards for installation and maintenance.
Installation and Testing: Installation procedures include air or water testing as per Building Regulations and BS EN 1610: 2015, with guidelines for rodding equipment and water jetting techniques.
Future Connections: Instructions for extending drainage systems include materials and procedures for installing new branch connections into existing drains.
Safety and Handling: Safety guidelines follow the Health and Safety at Work Act 1974, with recommendations for transportation and handling of PVCu pipes.
Flowloc Vortex Flow Control Unit: The Flowloc unit controls water discharge rates and is suitable for tank depths up to 4m, designed for easy maintenance access.
Standards and Accreditations: Various British and European standards applicable to the products are listed, including BS EN 1401 and BS EN 1610, along with BBA certifications.
Contact Information: Contact details for general inquiries, orders, and technical advice are provided.
See more

Catalog excerpts

Underground-2

Marley Underground Drainage Systems The Marley Plumbing & Drainage range of underground systems include the solid wall range, predominately for round the house drainage and Quantum structured wall range for sewer and highway drainage applications. Contents 4 Range overview 36 Adoptable inspection chambers Product specifications 24 Design 26 Pipe laying 42 Transition to other systems 40 Gully combinations 46 Installation 32 Shallow inspection chambers MARLEY Underground Drainage Systems | 3

 Open the catalog to page 2
Underground-3

Range overview Solid wall systems Rainwater system Gully Hopper UG47 Square hopper UG45 Soil system 87½° short radius bend UB411 Gully trap base UG44 Adoptable inspection chamber systems Ductile iron lid & cast iron frame UCL125 Marley have introduced a new adoptable inspection chamber range compliant with Sewers for Adoption and Building Regulations. Compatible systems for pipe & fitting connections: 110mm and 160mm solid wall drainage, and 150mm Quantum sewer structured wall drainage. All products in the Sewers for Adoption range are suitable for both adoptable and non-adoptable applications....

 Open the catalog to page 3
Underground-4

MARLEY Plumbing & Drainage Solutions Solid wall drainage systems PIPE SHORT RADIUS BENDS Size mm Code Length A B C D Colour Qty Double spigot with chamfer each end Size mm Code Angle A B C D Colour Qty Push-fit socket/spigot SLOTTED PIPE Double push-fit socket STRAIGHT COUPLINGS ADJUSTABLE BENDS (Supplied in U.V. resistant polythene bags) MULTIFLEX BENDS Socket should be solvent welded Single socket Double socket MECHANICAL BEND 6 MARLEY Underground Drainage Systems MARLEY Underground Drainage Systems 7

 Open the catalog to page 4
Underground-5

MARLEY Plumbing & Drainage Solutions Solid wall drainage systems LONG RADIUS BEND Size mm Code Angle A B C D Colour Qty RODDING POINT EQUAL BRANCHES Size mm Code Angle A B C D Colour Qty A15 loading. Black cover with four screw fixings and seal 15 loading. Aluminium cover with two screw fixings SQUARE RODDING POINT COVER (SPARE) UNEQUAL BRANCHES Solvent socket PRESSURE PLUG Push fits into plain end of pipe With rear access, socket/spigot Fitted with a twist and lock access cap which can be secured with a No. 8 screw 8 MARLEY Underground Drainage Systems MARLEY Underground Drainage Systems 9

 Open the catalog to page 5
Underground-6

Product specifications 250mm adoptable inspection chamber Suitable for up to 2m in depth 45º 45º INSPECTION CHAMBER BASE REDUCED ACCESS RING 315mm adoptable inspection chamber Suitable for up to 2m in depth DEEP INSPECTION CHAMBER RISER CLIP E UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH: N/A TOLERANCES: ISO8062-3 DCTG 10 LINEAR: N/A ANGULAR: N/A NAME ADDITIONAL INFORMATION: IF IN DOUBT, ASK DEBUR AND BREAK SHARP EDGES PK10 use with UCR3 riser. For B Zintec coated, supplied in packet of 10. DRAWN L. RATCLIFFE CHK'D BITUMEN COATED MANUFACTURING CODE: CLEAR OPENING:...

 Open the catalog to page 6
Underground-7

MARLEY Plumbing & Drainage Solutions Inspection chamber Lids and frames for inspection and deep inspection chambers 450MM INSPECTION CHAMBER BASE CHAMBER RISER Size mm Code A B C D E Colour Qty CAST IRON COVER AND FRAME Size mm Code A B C D Colour Qty Supplied with 4 blanking plugs. Max invert depth 1.2m (when used with UCR2 riser). 245mm high. All 110mm connections. The ‘D’ dimension relates to the height of side branches above invert of main channel 3.5 tonnes. Domestic driveway loading DUCTILE IRON LID AND CAST IRON FRAME Size mm Code Length A B C D Colour Qty Push fit ring seal joint into...

 Open the catalog to page 7
Underground-8

MARLEY Plumbing & Drainage Solutions Shallow inspection chambers SHALLOW INSPECTION CHAMBER Size mm Code A B C D Colour Qty Solid wall drainage systems LIFTING HANDLE Maximum invert depth - 600mm All 110mm socket connections INSP ECTION CHAMBER LID & FRAME Size mm Code Length A B C D Colour Qty DOUBLE BRANCH CHAMBER BASE 45° equal connections Includes two socket plugs and profiled insert Maximum invert depth - 600mm BOTTOM OUTLET CHAMBER BODY M aximum invert depth to side connections - 600mm 90° equal connections 4 x 110mm upstands, 3 open connections STRAIGHT DOUBLE SPIGOT OPEN CHANNEL CHAMBER...

 Open the catalog to page 8
Underground-9

Product spec ifications MARLEY Plumbing & Drainage Solutions Solid wall drainage systems LEVEL INVERT REDUCERS Size mm Code A B C D Colour Qty Push-fit socket inlet, 87/° socket outlet CONCENTRIC REDUCERS GULLY TRAP BASE Spigot to boss upstand Solvent socket inlet, 45° spigot outlet RECTANGULAR HOPPER ECCENTRIC REDUCERS Solvent socket to boss upstand SQUARE HOPPER URM425 Solvent socket to 68mm downpipe UA43 Universal waste to 110mm drain Solvent socket, accepts 68mm downpipe inside larger boss with two 50mm boss upstands Grating meets requirements of BS 4660: 2000 load Class K3 GRATING ASSEMBLY...

 Open the catalog to page 9
Underground-10

MARLEY Plumbing & Drainage Solutions Solid wall drainage systems Quantum structured wall drainage systems INLET RAISING PIECES Size mm Code A B C D Colour Qty QUANTUM SEWER PIPE Size mm Code Length A B C D Colour Qty Double spigot Solvent socket/spigot, four 50mm boss upstands, one open YARD GULLY Black high density polyethylene with spigot outlet and removable rodding access plug QUANTUM HIGHWAY PIPE *Pipe with coupling and seals GRATING AND FRAME FOR YARD GULLY Cast iron with hinged grating B125 loading (12.5 tonne test load) suitable for car park areas Socket/socket to suit thin wall clayware...

 Open the catalog to page 10
Underground-11

MARLEY Plumbing & Drainage Solutions Quantum structured wall drainage systems BENDS Size mm Code Angle A B C D Colour 150 UMB19Q 8772° 200 O O Double socket FLEXIBLE COUPLING Quantum/solid wall PVC to clayware pipe coupler Quantum socket to solid wall spigot EQUAL BRANCH PIPE SEALS Quantum pipe seal BS 4660 seal to convert Quantum 150mm sockets for use with BS EN 1401 pipe Snap cap to convert Quantum 150mm sockets for use with BS EN 1401 pipe * Supplied with black snap cap. To convert 150mm branch to accept 160mm solid wall pipe, a snap cap SNC6 and ring seal SR16OT must be fitted. POLYETHYLENE...

 Open the catalog to page 11
Underground-12

MARLEY Plumbing & Drainage Solutions Large diameter quantum highway 6M PIPE Size mm Code Length A B C D Colour Size mm Code A B C D Colour Qty Solid wall All pipes are socketed, or supplied with coupling and seal SEALING RING 160, 250 and 315mm branch connections are spigot ended and need to be used in conjunction with couplings and seals. For 160mm branch, use UME15C coupling. For 250mm branch, use UMD23 coupling. For 300mm branch use UMD33 coupling. Remove one snap cap and seal from UME15C to convert to 150mm quantum. The 375, 450 and 600mm branches are all socketed. FLEXIBLE COUPLING 22 MARLEY...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.