1. Catalogs
  2. Marley Plumbing & Drainage
  3. PVCu soil & waste design & installation

PVCu soil & waste design & installation

PVCu soil & waste design & installation
1 / 13 PagesView full catalog

PVCu soil & waste design & installation

Product catalog summary
Overview: Marley Plumbing & Drainage offers a wide range of soil and waste systems for commercial and residential use, adhering to UK and European standards with various jointing methods and innovative solutions.
Product Specifications: The document details design and installation for Marley PVCu soil & waste range, Akatherm HDPE drainage, and dBlue acoustic soil systems. Detailed specifications are available on the Marley website.
Standards and Certifications: Marley products comply with BS EN ISO 9001:2008 and BS EN ISO 14001:2004, ensuring quality and environmental management.
Key Components: Components include push-fit soil range, manifold systems, fire protection systems, WC connectors, and Durgo air admittance valves, enhancing installation flexibility and efficiency.
Design and Installation: Covers stack design, waste system design, jointing techniques, and pipe support systems, emphasizing adherence to British and European standards.
Marley Akatherm HDPE: Certified to BS EN 1519:2000, suitable for high-impact applications, offering flexibility and temperature resistance from -40°C to 100°C.
Marley dBlue Acoustic System: Designed for soundproofing, reducing noise to 19dB at a 4 l/s discharge rate, using a push-fit ring seal method.
Commercial Applications: Highlights use in commercial settings, emphasizing components like the Akavent aerator for high-rise buildings.
Material and Manufacture: Made from PVCu, PVCc, ABS, and Polypropylene, offering chemical and temperature resistance.
Design Considerations: Advises on sanitary pipework design, recommending adherence to The Building Regulations 2010 and BS EN 12056:2000.
Conclusion: Marley provides robust soil and waste systems with comprehensive guidance and adherence to industry standards.
Soil Stack Capacity: Capacity can be increased by installing a secondary ventilated stack as per BS EN 12056-2: 2000.
Design Considerations: Includes prevention of cross-flow, offsets in stacks, and stub waste and stacks with ventilation requirements.
Branch Pipe Specifications: Minimum gradients and guidelines for unventilated branch pipes, with potential for increased lengths if ventilated.
WC Manifold System: Connects toilets to a horizontal float, allowing adjustable angles and gradients.
Combined Branch Waste: Connects multiple appliances to a discharge stack, recommending anti-syphon traps.
Waste Traps: Designed to prevent blockages and maintain trap seals, with anti-syphon bottle traps for basins.
Durgo Air Admittance Valve: Reduces need for ventilating pipes, suitable for buildings up to ten storeys.
Fire Protection: Requires fire-resistant enclosures for pipes, with Marley fire collars or pipe wraps providing up to 4 hours of resistance.
Fire Resistance Specifications: Outlines fire resistance capabilities, with up to 4 hours of resistance with Marley products.
Jointing Techniques: Primary method is ring seal for large diameter PVCu pipes, with solvent weld jointing for small diameter waste pipework.
Pipe Support: Proper support is crucial, with recommended support centers for different pipe sizes.
Boss Pipe Connections: Four types of fittings for connecting small diameter waste pipes to vertical discharge stacks.
WC Connections: Two types of connectors for connecting to WC pans, suitable for push-fit or solvent weld jointing.
Installation and Testing: Installation should comply with BS 12056: 2000, with air testing guidelines provided.
Safety and Regulations: Based on Health and Safety At Work Act 1974 and The Construction (Design and Management) Regulations 1994.
Specifications and Procedures: Instructions for applying solvent cement and using adjustable spigot bends and extension pipes.
Storage Guidelines: Pipes should be stored on flat surfaces with specific stacking guidelines.
Standards and Accreditations: Lists applicable British and European standards and certifications.
Product Range and Applications: Offers diverse products for various applications, including commercial and residential settings.
Contact Information: Provides contact details for Marley's offices and customer service.
See more

Catalog excerpts

PVCu soil & waste design & installation-1

Soil & Waste Design & installation marley.co.uk MARLEY Akatherm HDPE |

 Open the catalog to page 1
PVCu soil & waste design & installation-2

Innovation & Expertise Marley Soil & Waste systems Marley Plumbing & Drainage offer a comprehensive range of soil and waste systems. Available with a variety of jointing methods, Marley products are manufactured to exacting UK and European standards and are designed for use on commercial projects as well as housing developments. Product specification information This guide contains design and installation information for the Marley PVCu soil & waste range. Design and installation guides are also available for Marley Akatherm HDPE drainage and dBlue acoustic soil. Product specification information...

 Open the catalog to page 2
PVCu soil & waste design & installation-3

PVCu soil & waste systems 88½° bend KB2 Commercial applications Bottle trap WBA4W Roof terminal SV42 ●● 2mm, 110 & 160mm push-fit and solvent 8 weld soil systems incorporating socketed and plain ended pipe Weathering slate SAS45 Marley Akatherm HDPE Pipe clip SC45 ●● 10mm WC connectors for all BS WC pans. 1 Available with solvent weld or push-fit joints. Pipe KP204 Pipe SL403 ●● 10mm WC manifold system allows ranges 1 of toilets to be connected horizontally. Ideal for commercial applications. The Marley Akatherm HDPE drainage range is certified to BS EN 1519: 2000 (licence number KM 545820) An...

 Open the catalog to page 3
PVCu soil & waste design & installation-4

The Marley soil & waste range offers an extensive choice of standard fittings for commercial and domestic projects. Pictured is a selection of key components within the range. Product specification information on the PVCu, HDPE drainage and dBlue acoustic soil ranges is available as a separate document. All documentation can be downloaded from marley.co.uk The collar boss offers the flexibility of 4 top and 4 side entries, allowing multiple inlet connections. Specifically designed to prevent cross-flow and to allow multiple low level bath or shower waste pipes to be connected to the stack above...

 Open the catalog to page 4
PVCu soil & waste design & installation-5

Sanitary pipework design All sanitary pipework systems should be designed to satisfy the following regulations and standards where applicable. • The Building Regulations 2010: Approved Document H, Section 1. • The Building Standards Technical Handbook (Scotland) 2010: Part M. • The Building Regulations (Northern Ireland) 2000, Technical Handbook N. Regular consultation is essential between Architects and Plumbing Engineers throughout the building design stage as the careful arrangement of kitchen and bathroom appliances will simplify the final sanitary pipework layout. This will help to ensure...

 Open the catalog to page 5
PVCu soil & waste design & installation-6

Design Stub stacks Offsets in the wet portion of a discharge stack should be avoided wherever possible but where they have to be fitted a large radius or two 45° bends should be used to create each change of direction. Offsets in lightly loaded stacks up to three storeys high do not require offset venting but on multi-storey buildings this may be necessary depending on the loading of the stack and the numbers of floors above the offset. The principles previously described for bends and branches at the base of a stack should also be applied. An unventilated stub stack terminated with an access...

 Open the catalog to page 6
PVCu soil & waste design & installation-7

Combined branch waste A combined branch waste is often used to connect a bath and/or shower and basin to the discharge stack as this allows waste pipework to be neatly concealed in a low level duct. Where this technique is adopted a 45° entry tee must be used to ensure the basin discharge is swept in the direction of flow towards the stack. The minimum distance between the bath or shower and basin connection should not be less than 500mm and it is recommended that an anti-syphon bottle trap is fitted to the basin or a vent provided to protect the appliance from It is recommended that the distance...

 Open the catalog to page 7
PVCu soil & waste design & installation-8

Durgo air admittance valve The Durgo valve is designed to reduce the number of ventilating pipes and subsequent roof penetrations in domestic, commercial and public buildings. Suitable for use in sanitary pipework systems up to ten storeys high, the valve must be fitted in a vertical position above the flood level of the highest appliance connecting to the stack. Valves should be installed within the building in a ventilated duct or roof space where there is no risk of freezing and must be accessible for inspection and testing. The 50, 82 and 110mm size valves have been assessed by the British...

 Open the catalog to page 8
PVCu soil & waste design & installation-9

Installation data Jointing techniques The ring seal has been successfully employed as the principal method of jointing large diameter PVCu pipes and fittings since their introduction over thirty years ago. This particular technique has proved extremely reliable as the joint can accommodate thermal movement that will occur as a result of temperature variations. An expansion gap of between 5-1 Omm should be allowed within each ring seal socket as each full length of pipe is installed and fixed using socket and barrel pipe clips. Solvent weld jointing is also widely used and many components in the...

 Open the catalog to page 9
PVCu soil & waste design & installation-10

Installation data Boss branches The Marley range of five boss branches are designed to allow multiple waste pipe connections to be made to the discharge stack from different directions. Four different side entry combinations are possible together with a rear if required. Staggered waste pipe connections, directly opposite are not permitted as cross-flow could occur. Boss pipes, boss connectors and strap-on bosses fitted with multi-fit T ring seals are suitable for use with PVCc or ABS waste systems to BS EN 1451-1 and metric size copper to Un-perforated boss upstands on boss pipes, branches and...

 Open the catalog to page 10
PVCu soil & waste design & installation-11

Installation data Up to six WCs can be connected to a soil stack using the WC manifold system and a single branch connection. By using a double branch connection, an additional six WCs can be connected. The table, right, details the angles of the manifolds for this installation. ANGLE OF MANIFOLD BRANCH 1. Select the adjustable bend angle required from the above diagram according to the WC position. Cut the bend with a hacksaw, removing the unwanted portion. File away any rough edges from the face of the fitting and wipe clean the bend and branch, with a dry cloth. Before jointing, the bend and...

 Open the catalog to page 11