Mechanical Heat Catalogue: Heaters - Controls
120Pages

{{requestButtons}}

Catalog excerpts

Mechanical Heat Catalogue: Heaters - Controls - 1

Products Company Scan with Red Laser — INDUSTRIAL -COMMERCIAL - RESIDENTIAL © Copyright 2013; TPI Corporation, P.O. Box 4973, Johnson City, TN 37602 January 1, 2013: Distribution Products Catalog Revision: 010113-001

Open the catalog to page 1
Mechanical Heat Catalogue: Heaters - Controls - 2

Table Of Contents Page AMPERAGE CHART & WARRANTY ELECTRIC HEAT COMFORT ZONES HAZARDOUS LOCATION & WASHDOWN HLA* Hazardous Location Fan Forced PHLA* Portable Hazardous Location Fan Forced FEP* Hazardous Location Convector 5500* Washdown Fan Forced Horizontal Fan Forced Horizontal or Vertical Fan Forced Downflow Fan Forced Multiple Wattage Fan Forced Cabinet Fan Forced WALL CONVECTORS 8500* Commercial Slope Top 8800* Institutional 4100* Recessed Commercial CEILING & COVE 3000 Fan Forced 3380 Commercial Fan Forced 3480* Commercial Recessed Fan Forced 3470* Commercial Surface Fan Forced CP/RCP...

Open the catalog to page 2
Mechanical Heat Catalogue: Heaters - Controls - 3

Amperage Chart & Electric Heat Products Limited Warranty 2 Note: All custom built products are subject to 100% cancellation/ restock charges. Heat Products 198 Series Elements All Other Heating Products Thermostats & Controls Products manufactured by TPI Corporation are warranted to the original consumer to be free from defects in material and workmanship for twelve (12) months from the original date of purchase. The TPI warranty does not cover products modified outside our factory, damage or failure caused by acts of God, abuse, misuse, connected to or placed on other than rated voltage,...

Open the catalog to page 3
Mechanical Heat Catalogue: Heaters - Controls - 4

Electric Heat Comfort Zones 3 INSULATION R-VALUE APPROXIMATE WATTAGE NEED PER SQUARE FOOT *”R”values are industry standards for insulation effectiveness. Ask company representative for assistance if you do not know “R” for your present structure insulation. Baseboard or wall mount style? Recessed or surface type? It’s easy to select the heater that’s right for you. 1. Measure the size of the room(s) or area you intend to heat for square footage. You will need the length times the width to get this calculation. 2. Find your location on the map above. This determines your basic heating zone....

Open the catalog to page 4
Mechanical Heat Catalogue: Heaters - Controls - 5

HLA Series Hazardous Location Fan Forced Unit Heater 4 FAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & 2. • Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain flammable gases, vapors, powdered metals or dust. • Permanently sealed, liquid to air, finned tube heat exchanger core. • Ethylene Glycol to water mixture used as a heat transfer fluid in the heater core, providing -45° C. (-49° F) freeze damage protection. •...

Open the catalog to page 5
Mechanical Heat Catalogue: Heaters - Controls - 6

HLA Series Hazardous Location Fan Forced Unit Heater Rating Definitions CLASS I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor. Application Examples: • Offshore and land based drilling rigs, petroleum exploration and testing facilities. • Petroleum refineries, gasoline storage and dispensing areas. • Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations. • Petrochemical companies that manufacture chemicals from gas or oil. • Dry cleaning facilities where vapors from cleaning...

Open the catalog to page 6
Mechanical Heat Catalogue: Heaters - Controls - 7

HLA Series Hazardous Location Fan Forced Unit Heater Mounting Bracket Kits 6 Column stabilizing components Roof or overhead structure Mounting arm assembly Attachment assembly HLHM Hanging Mounting Kit Simple and economical if adequate overhead structure exists. Requires 1/2’’ pipe, cut and threaded (not supplied). 3 1/2” Schedule 40 (Pipe) (Not Supplied) Wall bracket Mounting arm Attachment assembly Base assembly Wall or structure HLWM Wall Mounting Kit Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. HLPM Pipe Mounting Kit...

Open the catalog to page 7
Mechanical Heat Catalogue: Heaters - Controls - 8

HLA Series Hazardous Location Fan Forced Unit Heater Factory Installed Accessories & Physical Dimensions In-Built single pole thermostat 50° - 90° F Control transformer w/ primary fusing (Delete 24 suffix - add 120) 208/240V Control available on 208/240V units (Delete 24 suffix and add 208 OR 240) Disconnect Switch Pilot Light (Front View) (Rear View) (Side View) PHLA Series Portable Hazardous Location Fan Forced Unit Heater • • • • • • • • • • • 3.0 through 25 KW rating 208, 240, 480, 600 Volt available in selected capacities Cart has anti-static wheels to reduce the risk of static...

Open the catalog to page 8
Mechanical Heat Catalogue: Heaters - Controls - 9

FEP Series Single Phase Hazardous Location Wall Convector T-2A SERIES SINGLE PHASE Class 1, Group B, C & D Division 1 & 2 280° C / 536° F Standard Unit Unit with optional control section containing disconnect, pilot light, and thermostat (Suffix C1-TDP) CABINET LENGTH *Items may not be used with 22 Amp line voltage thermostat T-3A SERIES SINGLE PHASE Class 1, Group B, C & D Division 1 & 2 180° C / 356° F Unit with in-built EPET line voltage thermostat (Suffix T1 or T2) • Cabinet size 18” high, 9” wide. • Bottom In - Front Out air flow. • Wall mounting bracket supplied. • Units cannot be...

Open the catalog to page 9
Mechanical Heat Catalogue: Heaters - Controls - 10

FEP Series Three Phase Hazardous Location Wall Convector • Cabinet size 18” high, 9” wide. • ABS (American Bureau of Shipping) type approved. • Bottom In - Top Out air flow. • Wall mounting bracket supplied. O O • Units can not be operated in room ambients exceeding 104 F (40 C). • Heavy duty 16 gauge steel with gray epoxy textured powder coated finish. • 9” minimum clearance from bottom of heater to floor required. • Stainless steel cartridge element inserted into Aluminum finned Copper sheath. • Standard unit (without EPET thermostat or control section) is NEMA 4 rated. CABINET LENGTH...

Open the catalog to page 10
Mechanical Heat Catalogue: Heaters - Controls - 11

5500 Series Washdown Fan Forced Unit Heater The Washdown Series unit heaters are electric unit heaters constructed for use in areas that require washing or hosing of equipment due to dirty or dusty industrial environments in non-hazardous locations. The totally enclosed water-tight construction made with corrosion-resistant material make this series ideal for industrial heating applications. The Washdown Series is constructed with all built-in controls and safety temperature controls wired in a non-metallic Nema 4x control panel with single-point power connections. Rear View • Stainless...

Open the catalog to page 11

All Markel catalogs and technical brochures

Archived catalogs

  1. markel