Neutra separators for fat
8Pages

{{requestButtons}}

Catalog excerpts

Neutra separators for fat - 1

NEUTRA grease separators Separating technology

Open the catalog to page 1
Neutra separators for fat - 2

A problem that should not be underestimated: Fat in wastewater All vegetable and animals oils and fats represent a considerable additional load on our sewer system and wastewater treatment plants. It can cause pipes to clog up, accelerate corrosion, lead to unpleasant odors and make the operation of sewage treatment plants more difficult. For Grease separators for all requirements Grease separators provide the answer to fat problems – simply, quickly and environmentally appropriate. Depending on the intended use, NEUTRA grease separators are manufactured from reinforced concrete, plastic or...

Open the catalog to page 2
Neutra separators for fat - 3

The grease separator plants comprise three components: ■ NEUTRA sludge trap Heavy soil particles will settle in the sludge trap. ■ NEUTRA grease separator Owing to their low density, fats will remain on the surface and form a separate layer. ■ NEUTRA sampling manhole For taking representative waste- water samples from the flowing Disposal intervals must be scheduled such that the storage capacities of the sludge trap and the separator are not exceeded. In accordance with these components should be emptied completely, cleaned and refilled with fresh water, preferably every two weeks - but at...

Open the catalog to page 3
Neutra separators for fat - 4

Mall offers the optimal solution All Mall products are designed for ease of installation, easy handling using durable, mature technology. This keeps the costs for operating Dimensions / sizing The sizing of grease separators is carried out individually to make sure that your operational processes are matched with the right unit. Once the required volumes are established, a grease separator is selected from one of several nominal sizes (NS). must be sized according to the type Sizing parameters: ■ Maximum wastewater outflow Qs ■ Density of the fats and oils to be ■ Effect of any rinse aids...

Open the catalog to page 4
Neutra separators for fat - 5

Generally, the best and most expedient solution for installing a grease separator is underground. No specialist contractors are required - work can be carried out by local contractors. The space of the instal- lation remains usable for vehicular circulation or as a parking space. There are no problems with access to the plant for disposal purposes. The odor nuisance during disposal ■ Quality-controlled precast reinforced concrete construction without joints ■ Internal coating in accordance with ■ Stainless steel components ■ Flexible pipe joints with multiple seals for plastic pipes ■ No...

Open the catalog to page 5
Neutra separators for fat - 6

Grease separator and sludge Where the available space outside is limited, or where the plant is part of an upgrade in existing rooms it is sions. The installation can be inside any existing rooms that are frost-pro- of. These rooms must have ventilation (air inlet and discharge). Owing to the slender shape and low weight of the plant it will fit even through narrow small rooms. In the standard versions, the covers are opened manually. The suction hose used for disposal is taken through the building to the place where the plant is installed. Then the separator is manual- ly cleaned with a...

Open the catalog to page 6
Neutra separators for fat - 7

General inspection, maintenance Prior to commissioning and after five years of operation, a general inspection including a leak test must be conduc- ted by a specialist. The annual mainte- nance can be conducted by a specia- list, or directly by the plant operator, provided that a specialist training pro- gramme with instructions on site has been completed in accordance with intervals between disposals must be determined in such a manner that the storage capacity is not exceeded. We recommend full emptying of the sludge trap and separator system eve- ry two weeks. The internal monitoring,...

Open the catalog to page 7
Neutra separators for fat - 8

Project report Grease separators Carry out project planning with Mall's help You'll find the NEUTRAplan online sizing program for grease separators and light fluid separators under The first German McDonald's restau- rant opened on 4 December 1971 in Munich. McDonald's and its franchi- sees now employ almost 60,000 staff Germany. McDonald's Germany is a market leader in the catering industry. McDonald's produces fatty wastewater every day in its kitchen areas, which cannot be discharged into the sewage system without pre-treatment. Here grease separator systems from Mall ensure that the...

Open the catalog to page 8