SVA-R
6Pages

{{requestButtons}}

Catalog excerpts

SVA-R - 1

SVA-R rectangular VAV dampers Rectangular air flow damper for Variable Air Volume (VAV) installations. The SVA-R dampers are used to adjust the air flow to a bypass or a room based on a 0-10 V signal provided by a controller of temperature. The command signal sent by the controller of the room, position the actuator to control the flow of the need the enclosure. You can change a posteriori the flow Vmin and Vmax using a remote control.

Open the catalog to page 1
SVA-R - 2

CLASSIFICATION SVA-R Volume air variable rectangular damper. Maximum air flow (Vmax) and minimum (Vmin) Setting calibrated at the factory according to Customer specifications. ... / M / Mode of operation of the damper type Master. ... / S / Mode of operation of the damper type Slave. .../CON 0-10/ 0-10 V proportional control. .../CON 3P/ 3 points control. .../AIS/ Thermo-acoustical insulation. MATERIAL Galvanized steel housing, cross differential pressure measurement aluminum, connect in ABS and measuring tubes the actuator in red / blue silicone. Damper foam seal from EPDM. ACCESSORIES RDG...

Open the catalog to page 2
SVA-R - 3

-Take precautions to ensure that flow of air to get uniformly to the damper and prevent their installation in the presence of vibrations. - The inner dimension of the air ducts can not be smaller than inside dimension of the damper. Pressure loss and Free face area: DPt (Pa) , Ak (m²) HxL 100 150 200 250 300 400 500 600 Q (m³/h) = Vk(m/s) x Ak (m²) x 3600 (*) Damper opened

Open the catalog to page 3
SVA-R - 4

Technical selection Sound pressure dB(A). 100Pa DIM LxH 600x100 Sound attenuation. dB/Oct. (VDI 2081). Hz Duct Room Terminal reflexion Reverberant chamber Reverberant chamber

Open the catalog to page 4
SVA-R - 5

Electrical connection SIEMENS SVA-R (Constant) SVA-R + RDG regulator (standard connection) Red Black Violet Orange Grey Pink AC 24 V N Contact Contact DC 0..10 V Set point DC 0..10 V Technical data • 24 V AC/DC • 3,5 W / 6VA • 0,9m 6 x 0,75 mm² • III as per EN 60730 • IP54 as per IEC 529 • EMC CE according to 89/336 EEC Red Black Grey Pink

Open the catalog to page 5
SVA-R - 6

Electrical connection BELIMO SVA-R (VAV) L Damper closed - CAV step Q min SVA-R (Constant) MP / Actual value signal MP / Actual value signal 0...10V / 2...10V SVA-R + CR24-B1 regulator (standard connection) Technical data • 24 V AC/DC • 2,5 W / 6VA • 1m 4 x 0,75 mm² • III as extra low voltage EN 60730 • IP54 • CE to 89/336 EEC

Open the catalog to page 6

All MADEL catalogs and technical brochures

  1. WAAB 4-WAY

    7 Pages

  2. SCC

    11 Pages

  3. LMT-S

    4 Pages

  4. MADEL BMC

    4 Pages

  5. MADEL AMT-AC

    6 Pages

  6. TEO

    3 Pages

  7. LOOK

    7 Pages

  8. KAP

    6 Pages

  9. TAU

    3 Pages

  10. UFA

    4 Pages

  11. LOF&LAIF

    6 Pages

  12. DXL

    4 Pages

  13. DBQ

    7 Pages

  14. KSP SUB

    2 Pages

  15. KCA

    2 Pages

  16. KBY

    3 Pages

  17. ZMARTBOX

    4 Pages

  18. FOC-EIS-120

    6 Pages

  19. FTR

    3 Pages

  20. FDS-MINI

    3 Pages

  21. FSC-60

    3 Pages

  22. WAAB-300

    46 Pages

  23. WAAB-600

    46 Pages

  24. FBK-EIS-120

    11 Pages

  25. FOC-EIS-180

    6 Pages

  26. FOC-EIS-90

    5 Pages

  27. FOK-EIS-180

    6 Pages

  28. INTERFACES

    1 Pages

  29. K1

    2 Pages

  30. KSP

    2 Pages

  31. KFC-PLUS

    2 Pages

  32. KRC-PLUS

    2 Pages

  33. SKP

    3 Pages

  34. SKC-C

    3 Pages

  35. SKC-R

    3 Pages

  36. SMS

    4 Pages

  37. SCC

    4 Pages

  38. SQR

    7 Pages

  39. CRG

    8 Pages

  40. RXO

    14 Pages

  41. AXP

    5 Pages

  42. AXO

    30 Pages

  43. FOK-EIS-120

    6 Pages

  44. SVA-C

    3 Pages

  45. DCG

    12 Pages

  46. AX6

    10 Pages

  47. PLAY

    11 Pages

Archived catalogs

  1. madel

    9 Pages