SVA-C

SVA-C

SVA-C

Product catalog summary
Introduction
The SVA-C circular VAV dampers by MADEL are designed for Variable Air Volume (VAV) installations. These dampers adjust airflow to a bypass or room based on a 0-10 V signal from a temperature controller. The actuator positions itself to control the necessary airflow, and a foam seal ensures airtight closure when needed. Flow settings (Vmin and Vmax) can be adjusted remotely.

Classification
The SVA-C dampers are classified by their maximum (Vmax) and minimum (Vmin) airflow settings, calibrated at the factory. They operate in Master or Slave modes and support 0-10 V proportional control or 3-point control. Thermo-acoustical insulation is available.

Material and Construction
The dampers feature a galvanized steel housing with aluminum cross differential pressure measurement. Connections are made with ABS, and measuring tubes are in red/blue silicone. The foam seal is made from EPDM.

Accessories
Available accessories include the RDG 400 proportional temperature controller with a digital display and the RDG 400KN with KNX communication for BMS integration.

Fixing Systems
The dampers are designed for connection into circular metallic ducts.

Specifications
The specification text outlines the supply and mounting of the SVA-C dampers, detailing the materials and control modes.

Performance Data
The document includes tables and graphs showing recommended airflow, pressure loss, and sound power levels for various duct sizes and flow rates. Key data points include minimum and maximum airflow (Qmin and Qmax), pressure drop (Dpt), and velocity in the duct.

Conclusion
For further technical details, contact [email protected].
See more

Catalog excerpts

SVA-C-1

SVA C SVA-C circular VAV dampers Circular air flow damper for Variable Air Volume (VAV) installations. The SVA-C dampers are used to adjust the air flow to a bypass or a room based on a 0-10 V signal provided by a controller of temperature. The command signal sent by the controller of the room, position the actuator to control the flow of the need the enclosure. A foam seal inside the perimeter of the damper seals the air in case of total closure order. You can change a posteriori the flow Vmin and Vmax using a remote control.

 Open the catalog to page 1
SVA-C-2

CLASSIFICATION SVA-C SVA-C Volume air variable circular damper. Maximum air flow (Vmax) and minimum (Vmin) setting calibrated at the factory according to customer specifications. ... / M / Mode of operation of the damper type Master. ... / S / Mode of operation of the damper type Slave. .../CON 0 10/ 0-10 V proportional control. 0-10/ 0 10 .../CON 3P/ 3 points control. .../AIS/ Thermo-acoustical insulation. MATERIAL Galvanized steel housing, cross differential pressure measurement aluminum, connect in ABS and measuring tubes the actuator in red / blue silicone. Damper foam seal from EPDM. ACCESSORIES...

 Open the catalog to page 2
SVA-C-3

MADEL SVA-C SOUND POWER LEVEL Q (m3/h) Qmin 71 Qmax 198 Qmin 110 Qmax 309 Qmin 181 Qmax 507 Qmin 283 Qmax 792 Qmin 442 Qmax 1237 Qmin 701 Qmax 1964 Qmin 891 Qmax 2494 Qmin 1131 Qmax 3167 RECOMMENDED AIRFLOW FREE VELOCITY, PRESSURE LOSS Q (m / h) EXAMPLE: Selection of SVA-C regulator from minimum (V min) and maximum (Vmax) airflow Minimum Flow. V min (m3/h) Note: More information In [email protected] SVA-C-12/02

 Open the catalog to page 3

All MADEL catalogs and technical brochures

  1. KAM

    6  Pages

  2. WAAB 4-WAY

    7  Pages

  3. SCC

    11  Pages

  4. LMT-S

    4  Pages

  5. MADEL BMC

    4  Pages

  6. MADEL AMT-AC

    6  Pages

  7. TEO

    3  Pages

  8. LOOK

    7  Pages

  9. KAP

    6  Pages

  10. TAU

    3  Pages

  11. UFA

    4  Pages

  12. LOF&LAIF

    6  Pages

  13. DXL

    4  Pages

  14. DBQ

    7  Pages

  15. SVA-R

    6  Pages

  16. KSP SUB

    2  Pages

  17. KCA

    2  Pages

  18. KBY

    3  Pages

  19. ZMARTBOX

    4  Pages

  20. FOC-EIS-120

    6  Pages

  21. FTR

    3  Pages

  22. FDS-MINI

    3  Pages

  23. FSC-60

    3  Pages

  24. WAAB-300

    46  Pages

  25. WAAB-600

    46  Pages

  26. FBK-EIS-120

    11  Pages

  27. FOC-EIS-180

    6  Pages

  28. FOC-EIS-90

    5  Pages

  29. FOK-EIS-180

    6  Pages

  30. INTERFACES

    1  Page

  31. K1

    2  Pages

  32. KSP

    2  Pages

  33. KFC-PLUS

    2  Pages

  34. KRC-PLUS

    2  Pages

  35. SKP

    3  Pages

  36. SKC-C

    3  Pages

  37. SKC-R

    3  Pages

  38. SMS

    4  Pages

  39. SCC

    4  Pages

  40. SQR

    7  Pages

  41. CRG

    8  Pages

  42. RXO

    14  Pages

  43. AXP

    5  Pages

  44. AXO

    30  Pages

  45. FOK-EIS-120

    6  Pages

  46. DCG

    12  Pages

  47. AX6

    10  Pages

  48. PLAY

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.