Catalog excerpts
RXO fixed vanes swirl diffusers RXO swirl diffusers are designed to be applied in air conditioning ventilation and heating systems. They can be mounted in false ceilings or suspended from the ceiling. The design of their vanes and its radial arrangement in the diffuser cause swirl air supply with a coanda effect, which provides a high level of induction rate of the air in the atmosphere and reducing the stratification. Their sectored vanes emit a uniform air flow all over the passage section. RXO series diffusers admit a flow variation of 60% keeping the air stream stable. These diffusers can be used from 2,6 up to 4 meters high and at a temperature differential up to 12º C. Models: RXO-S RXO-KLIN RXO-C 1
Open the catalog to page 1RXO-S RXO-S Classification RXO-S Square diffuser with vanes in circular radial arrangement. …/SR/ Reduced face area in relation to the diffuser size. …/T15/ Panel with angled borders to replace an angled ceiling tile profile 15 mm. …/T24/ Panel with angled borders to replace an angled ceiling tile profile 24 mm. Diffuser constructed from galvanised steel. All diffusers are provided with a seal on the back of the frame in order that the perimeter in contact with the plenum box or the ceiling is airtight.
Open the catalog to page 2Additional accessories PMXO PMXO Crossbar suitable for mounting in false ceiling with rectangular duct. BOXSTAR Pyramidal plenum box with a lateral circular connection. It includes supports to hang from the ceiling. The crossbar is supplied separately to be assembled manually on the work site. Made in galvanised steel. …-R Plenum box with a flow damper in the spigot. .../S/ Upper circular connection plenum box . …/AIS/ Plenum box thermo acoustically insulated by a foam with a coefficient of thermal y conductivity of 0,04 w/mk. This foam complies with the fire reaction specifications: UNE...
Open the catalog to page 3Fixing systems 1) Connection into the crossbar or to the plenum box by means of central screw. Finishes Fi i h M9016 Painted in white similar to RAL 9016. R9010 Painted in white RAL 9010. RAL... Painted in other RAL colours. Specification text Supply and mounting of square swirl diffuser with fixed blades with radial vanes series RXO-S+BOXSTAR-R M9016 dim. 600 constructed from galvanised steel paint in white M9016. With lateral circular connection pyramidal plenum box and air flow damper in the spigot BOXSTAR-R. Manufacturer MADEL.
Open the catalog to page 4RXO-S-KLIN Hinged removable core diffuser for the easy access to the installations above the ceiling with no need of tools, by means of PUSH fasteners. By slightly pressing on the invisible latch, the core opens, remaining hinged on one side. If necessary the core can be easily removed for maintenance of HVAC installations. Material Diffuser constructed from galvanised steel. Additional accessories PLK Plenum box fixed to the diffuser with an upper connection. Made in galvanised steel. …-R Plenum box with a flow damper in the spigot. …/L/ Plenum box with a lateral connection. …/AIS/ Plenum...
Open the catalog to page 5Fixing systems 1) Fixing with supports to hang from the ceiling with drops rods. Finishes M9016 Painted in white similar to RAL 9016. R9010 Painted in white RAL 9010. RAL... Painted in other RAL colours. Specification text Supply and mounting of square swirl diffuser with fixed blades with hinged removable core without tools, by pressing on the invisible PUSH fasteners series RXO-S-KLIN+PLK-R M9016 dim. (mm) constructed from galvanised steel paint in white M9016. With upper circular connection plenum box and air flow damper in the spigot PLK-R. Manufacturer MADEL.
Open the catalog to page 6RXO-C Classification RXO-C RXO-C Circular diffuser with vanes in circular radial arrangement. Diffuser constructed from galvanised steel. All diffusers are provided with a seal on the back of the frame in order that the perimeter in contact with the plenum box or ceiling is airtight. PMXO Crossbar suitable for mounting in false ceiling with rectangular duct. PLXOC Plenum box with a lateral circular connection. M d i galvanised steel. ti Made in l i d t l …-R Plenum box with a flow damper in the spigot. …/S/ Plenum box with an upper connection. …/AIS/ Plenum box thermo acoustically insulated...
Open the catalog to page 7Fixing Fi i systems t 1) Connection into the crossbar or to the plenum box by means of central screw. 1) Finishes M9016 Painted in white similar to RAL 9016. R9010 Painted in white RAL 9010. RAL... Painted in other RAL colours. Specification text Supply and mounting of circular swirl diffuser with fixed blades with radial vanes series RXO-C+PLXOC-R M9016 dim. 600 constructed from galvanised steel paint in white M9016. With lateral circular connection plenum box and air flow damper in the spigot PLXOC-R. Manufacturer MADEL.
Open the catalog to page 8RECOMMENDED VELOCITY. FREE VELOCITY, PRESSURE LOSS AND SOUND POWER LEVEL, THROW WITH CEILING EFFECT. FREE FACE AREA (m2). Q ( m3 / h ) Note: In MadelMedia Octava band centre frequency in Hz.
Open the catalog to page 9CORRECTION FACTOR FOR VERTICAL DIFFUSION (bV) FOR DT (-). CORRECTON FACTOR FOR THROW (L0.2) DT (-). Kh = Correction factor for the vertical diffusion. Kl = Correction factor for the throw. INDUCTION RATIO. t room - t x t room - t supply
Open the catalog to page 10RECOMMENDED VELOCITY. FREE VELOCITY, PRESSURE LOSS AND SOUND POWER LEVEL, THROW WITH CEILING EFFECT. FREE FACE AREA (m2). Q ( m3 / h ) Note: In MadelMedia Octava band centre frequency in Hz.
Open the catalog to page 11CORRECTION FACTOR FOR VERTICAL DIFFUSION (bV) FOR DT (-). CORRECTON FACTOR FOR THROW (L0.2) DT (-). Kh = Correction factor for the vertical diffusion. Kl = Correction factor for the throw. INDUCTION RATIO. t room - t x t room - t supply l
Open the catalog to page 12RECOMMENDED VELOCITY. FREE VELOCITY, PRESSURE LOSS AND SOUND POWER LEVEL, THROW WITH CEILING EFFECT. FREE FACE AREA (m2). Afree Qmin. Qmax. m2 m3/h m3/h Q ( m3 / h ) Note: In MadelMedia Octava band centre frequency in Hz.
Open the catalog to page 13CORRECTION FACTOR FOR VERTICAL DIFFUSION (bV) FOR DT (-). CORRECTON FACTOR FOR THROW (L0.2) DT (-). Kh = Correction factor for the vertical diffusion. Kl = Correction factor for the throw. INDUCTION RATIO. t room - t x t room - t supply l
Open the catalog to page 14All MADEL catalogs and technical brochures
-
WAAB 4-WAY
7 Pages
-
SCC
11 Pages
-
LMT-S
4 Pages
-
MADEL BMC
4 Pages
-
MADEL AMT-AC
6 Pages
-
TEO
3 Pages
-
LOOK
7 Pages
-
KAP
6 Pages
-
TAU
3 Pages
-
UFA
4 Pages
-
LOF&LAIF
6 Pages
-
DXL
4 Pages
-
DBQ
7 Pages
-
SVA-R
6 Pages
-
KSP SUB
2 Pages
-
KCA
2 Pages
-
KRC-PLUS-FREE-COOLING
4 Pages
-
KBY
3 Pages
-
ZMARTBOX
4 Pages
-
FOC-EIS-120
6 Pages
-
FTR
3 Pages
-
FDS-MINI
3 Pages
-
FSC-60
3 Pages
-
WAAB-300
46 Pages
-
WAAB-600
46 Pages
-
FBK-EIS-120
11 Pages
-
FOC-EIS-180
6 Pages
-
FOC-EIS-90
5 Pages
-
FOK-EIS-180
6 Pages
-
INTERFACES
1 Pages
-
K1
2 Pages
-
KSP
2 Pages
-
KFC-PLUS
2 Pages
-
KRC-PLUS
2 Pages
-
SKP
3 Pages
-
SKC-C
3 Pages
-
SKC-R
3 Pages
-
SMS
4 Pages
-
SCC
4 Pages
-
SQR
7 Pages
-
CRG
8 Pages
-
AXP
5 Pages
-
AXO
30 Pages
-
FOK-EIS-120
6 Pages
-
SVA-C
3 Pages
-
DCG
12 Pages
-
AX6
10 Pages
-
PLAY
11 Pages
-
ZONING SYSTEM CATALOGUE
20 Pages
Archived catalogs
-
madel
9 Pages
-
DCN circular diffusers
8 Pages