Catalog excerpts
KRC-PLUS application for FREE-COOLING The FREE-COOLING application for the control panel KRC-PLUS means the development of zoning systems to the rationalization of energy use and management of air quality in the full HVAC systems in homes and offices. The use of an outdoor temperature sensor and a CO2 sensor optimize energy consumption and air quality in the installation, significantly reducing the power consumption of air conditioners. • Using fresh air to cool the building It prevents starting the compressor when the outside temperature is adequate to cool the room, taking advantage of free cooling air and significantly reducing power consumption. • Automatic change from free-cooling mode to normal mode The system uses outdoor air or the AHU according to the outdoor temperature. The user should not worry about activating any device. • Management of air quality Using a CO2 sensor (installed in the duct or one of the rooms), the system detects if there is bad air quality and active the intake of fresh air through a heat recovery unit or a cabinet fan. The system automatically returns to normal after the return to air quality. Very suitable for control of areas with variable occupancy (meeting rooms, classrooms, ...) or areas with a higher concentration of air pollution (smoke, dust, ) (smoke dust ...). • Protection of the building facing the sick building syndrome The system can perform periodic automatic ventilations to prevent humidities and air stagnation even in vacant buildings. Prevents sick building syndrome.
Open the catalog to page 1MADEL Zoning Kit designed for independent temperature control and air quality in HVAC systems, consisting of a direct expansion AHU and a cabinet fan for fresh air and / or a heat recovery unit for free cooling control and air quality. TYPICAL EXAMPLE OF INSTALLATION Technical specifications: Control board (receiver) Power supply 230 VAC ± 10%, 50/60 Hz Consumption: 10 VA 6 outputs potential-free relays 230 VAC x 10 A for f controlling the air conditioning equipment Sixteen 24 VDC outputs, for zone control Digital input for remote ON/OFF Protection class: IP 20 Safety sensor NTC 10 K air...
Open the catalog to page 2Control facilities for up to 16 independent temperature zones and control unizone of air quality (return sensor or in the i th worst room) A t t ) Automatic management of start of the free-cooling or th AHU according t an outdoor sensor ti t f t t f th f li the di to td temperature. air conditioning control + air quality + free cooling with outdoor cabinet fan V. EXT. BY-PASS BY PASS C. AIRE NUEVO CO2*: SONDA CO2 TODO / NADA. Instalar en sala o en retorno. S1: SONDA DE RETORNO Sonda de Seguridad RETORNO. Seguridad. S3: SONDA AIRE EXTERIOR. air conditioning control + air quality with heat...
Open the catalog to page 3MADEL COMPONENTS KRC-PLUS Control KRC PLUS C t l panels and th l d thermostats. t t ZP-AZ Motorised dampers for grilles (24 VdC). ZC Motorised dampers for circualr ducts (24 VdC). ZQ Motorised dampers for rectangular ducts (24 VdC). ZS By-pass dampers. SQR-FC-M7 24/230V Air intake or exhaust rectangular dampers with a 2 cable actuator at 24 or 230v. SCC-FC-M7 24/230V Air intake or exhaust circular dampers with a 2 cable actuator at 24 or 230v. NTC-EXT Fresh air sensor. CO2-D On/Off CO2 sensor for duct mounting. CO2-M On/Off CO2 sensor for room mounting . CAV Cabinet fan for fresh air. MODEL...
Open the catalog to page 4All MADEL catalogs and technical brochures
-
WAAB 4-WAY
7 Pages
-
SCC
11 Pages
-
LMT-S
4 Pages
-
MADEL BMC
4 Pages
-
MADEL AMT-AC
6 Pages
-
TEO
3 Pages
-
LOOK
7 Pages
-
KAP
6 Pages
-
TAU
3 Pages
-
UFA
4 Pages
-
LOF&LAIF
6 Pages
-
DXL
4 Pages
-
DBQ
7 Pages
-
SVA-R
6 Pages
-
KSP SUB
2 Pages
-
KCA
2 Pages
-
KBY
3 Pages
-
ZMARTBOX
4 Pages
-
FOC-EIS-120
6 Pages
-
FTR
3 Pages
-
FDS-MINI
3 Pages
-
FSC-60
3 Pages
-
WAAB-300
46 Pages
-
WAAB-600
46 Pages
-
FBK-EIS-120
11 Pages
-
FOC-EIS-180
6 Pages
-
FOC-EIS-90
5 Pages
-
FOK-EIS-180
6 Pages
-
INTERFACES
1 Pages
-
K1
2 Pages
-
KSP
2 Pages
-
KFC-PLUS
2 Pages
-
KRC-PLUS
2 Pages
-
SKP
3 Pages
-
SKC-C
3 Pages
-
SKC-R
3 Pages
-
SMS
4 Pages
-
SCC
4 Pages
-
SQR
7 Pages
-
CRG
8 Pages
-
RXO
14 Pages
-
AXP
5 Pages
-
AXO
30 Pages
-
FOK-EIS-120
6 Pages
-
SVA-C
3 Pages
-
DCG
12 Pages
-
AX6
10 Pages
-
PLAY
11 Pages
-
ZONING SYSTEM CATALOGUE
20 Pages
Archived catalogs
-
madel
9 Pages
-
DCN circular diffusers
8 Pages