FOC-EIS-120
6Pages

{{requestButtons}}

Catalog excerpts

FOC-EIS-120 - 1

Fire dampers for circular duct mounting. Dampers designed to maintain the fire resistance of the wall or the floor, in which a passage for ventilation, heating or air conditioning ducts has been made. They have been tested in accordance with the standards EN-1366-2 achieving the fire resistance EIS 120 (Integrity, Insulation and smoke leakage during 120 minutes), to comply with building regulations for fire safety. In case of fire, the damper stops the air passage at 72ºC by means of a fusible link that closes a blade valve. An expanding joint and another one of air tightness, as much prevent the propagation of smoke to high as to low temperature. These dampers full fill the required conditions for the (S) symbol, air-tightness to cold smoke. In case of fire, poisoning by smoke is the main cause of death. Dampers with the displaced mechanism that facilitates a good installation.

Open the catalog to page 1
FOC-EIS-120 - 2

…-M7F Damper operated by an actuator with switch off device at 24 or 230v. …-MA Manual resetting damper. Is not necessary to open the box device.

Open the catalog to page 2
FOC-EIS-120 - 3

Dampers made from galvanised steel and non-combustible board. ADDITIONAL ACCESSORIES /PIF/ Open / closed switches device. 200 FBC/FBA FEC/FEA CLOSED /FBC/ Electromagnet at 24/48v. Closes by electric current. /FBA/ Electromagnet at 230v. Closes by electric current. /FEC/ Electromagnet at 24/48v. Closes when current stops. /FEA/ Electromagnet at 230v. Closes when current stops. Position actuator

Open the catalog to page 3
FOC-EIS-120 - 4

FIXING SYSTEMS The damper is fixed in accordance with the figure. The damper cannot be fixed in place when vibrations are occurring. 145 The dampers must be installed in a way that they can be operated manually. Precautions will have to be taken in order to ensure that the air flow reaches the fire damper uniformly. W SPECIFICATION TEXT Supply and mounting of fire damper for circular duct classed EIS-120 in accordance to the European standard EN-1366-2 series FOC-EIS-120-M7F24 D=200. Operated by means of a servomotor at 24v M7F24, start and end of course switches. Dampers made from...

Open the catalog to page 4
FOC-EIS-120 - 5

PRESSURE LOSS AND SOUND POWER LEVEL.

Open the catalog to page 5
FOC-EIS-120 - 6

PRESSURE LOSS AND SOUND POWER LEVEL. PRESSURE LOSS AND SOUND POWER LEVEL. 300 200 150 100

Open the catalog to page 6

All MADEL catalogs and technical brochures

  1. WAAB 4-WAY

    7 Pages

  2. SCC

    11 Pages

  3. LMT-S

    4 Pages

  4. MADEL BMC

    4 Pages

  5. MADEL AMT-AC

    6 Pages

  6. TEO

    3 Pages

  7. LOOK

    7 Pages

  8. KAP

    6 Pages

  9. TAU

    3 Pages

  10. UFA

    4 Pages

  11. LOF&LAIF

    6 Pages

  12. DXL

    4 Pages

  13. DBQ

    7 Pages

  14. SVA-R

    6 Pages

  15. KSP SUB

    2 Pages

  16. KCA

    2 Pages

  17. KBY

    3 Pages

  18. ZMARTBOX

    4 Pages

  19. FTR

    3 Pages

  20. FDS-MINI

    3 Pages

  21. FSC-60

    3 Pages

  22. WAAB-300

    46 Pages

  23. WAAB-600

    46 Pages

  24. FBK-EIS-120

    11 Pages

  25. FOC-EIS-180

    6 Pages

  26. FOC-EIS-90

    5 Pages

  27. FOK-EIS-180

    6 Pages

  28. INTERFACES

    1 Pages

  29. K1

    2 Pages

  30. KSP

    2 Pages

  31. KFC-PLUS

    2 Pages

  32. KRC-PLUS

    2 Pages

  33. SKP

    3 Pages

  34. SKC-C

    3 Pages

  35. SKC-R

    3 Pages

  36. SMS

    4 Pages

  37. SCC

    4 Pages

  38. SQR

    7 Pages

  39. CRG

    8 Pages

  40. RXO

    14 Pages

  41. AXP

    5 Pages

  42. AXO

    30 Pages

  43. FOK-EIS-120

    6 Pages

  44. SVA-C

    3 Pages

  45. DCG

    12 Pages

  46. AX6

    10 Pages

  47. PLAY

    11 Pages

Archived catalogs

  1. madel

    9 Pages