Fire dampers for circular duct mounting. Dampers designed to maintain the fire resistance of the wall or the floor, in which a passage for ventilation, heating or air conditioning ducts has been made. They have been tested in accordance with the standards EN-1366-2 achieving the fire resistance EIS 120 (Integrity, Insulation and smoke leakage during 120 minutes), to comply with building regulations for fire safety. In case of fire, the damper stops the air passage at 72ºC by means of a fusible link that closes a blade valve. An expanding joint and another one of air tightness, as much prevent the propagation of smoke to high as to low temperature. These dampers full fill the required conditions for the (S) symbol, air-tightness to cold smoke. In case of fire, poisoning by smoke is the main cause of death. Dampers with the displaced mechanism that facilitates a good installation.
Open the catalog to page 1…-M7F Damper operated by an actuator with switch off device at 24 or 230v. …-MA Manual resetting damper. Is not necessary to open the box device.
Open the catalog to page 2Dampers made from galvanised steel and non-combustible board. ADDITIONAL ACCESSORIES /PIF/ Open / closed switches device. 200 FBC/FBA FEC/FEA CLOSED /FBC/ Electromagnet at 24/48v. Closes by electric current. /FBA/ Electromagnet at 230v. Closes by electric current. /FEC/ Electromagnet at 24/48v. Closes when current stops. /FEA/ Electromagnet at 230v. Closes when current stops. Position actuator
Open the catalog to page 3FIXING SYSTEMS The damper is fixed in accordance with the figure. The damper cannot be fixed in place when vibrations are occurring. 145 The dampers must be installed in a way that they can be operated manually. Precautions will have to be taken in order to ensure that the air flow reaches the fire damper uniformly. W SPECIFICATION TEXT Supply and mounting of fire damper for circular duct classed EIS-120 in accordance to the European standard EN-1366-2 series FOC-EIS-120-M7F24 D=200. Operated by means of a servomotor at 24v M7F24, start and end of course switches. Dampers made from...
Open the catalog to page 4PRESSURE LOSS AND SOUND POWER LEVEL.
Open the catalog to page 5PRESSURE LOSS AND SOUND POWER LEVEL. PRESSURE LOSS AND SOUND POWER LEVEL. 300 200 150 100
Open the catalog to page 6All MADEL catalogs and technical brochures
-
WAAB 4-WAY
7 Pages
-
SCC
11 Pages
-
LMT-S
4 Pages
-
MADEL BMC
4 Pages
-
MADEL AMT-AC
6 Pages
-
TEO
3 Pages
-
LOOK
7 Pages
-
KAP
6 Pages
-
TAU
3 Pages
-
UFA
4 Pages
-
LOF&LAIF
6 Pages
-
DXL
4 Pages
-
DBQ
7 Pages
-
SVA-R
6 Pages
-
KSP SUB
2 Pages
-
KCA
2 Pages
-
KRC-PLUS-FREE-COOLING
4 Pages
-
KBY
3 Pages
-
ZMARTBOX
4 Pages
-
FTR
3 Pages
-
FDS-MINI
3 Pages
-
FSC-60
3 Pages
-
WAAB-300
46 Pages
-
WAAB-600
46 Pages
-
FBK-EIS-120
11 Pages
-
FOC-EIS-180
6 Pages
-
FOC-EIS-90
5 Pages
-
FOK-EIS-180
6 Pages
-
INTERFACES
1 Pages
-
K1
2 Pages
-
KSP
2 Pages
-
KFC-PLUS
2 Pages
-
KRC-PLUS
2 Pages
-
SKP
3 Pages
-
SKC-C
3 Pages
-
SKC-R
3 Pages
-
SMS
4 Pages
-
SCC
4 Pages
-
SQR
7 Pages
-
CRG
8 Pages
-
RXO
14 Pages
-
AXP
5 Pages
-
AXO
30 Pages
-
FOK-EIS-120
6 Pages
-
SVA-C
3 Pages
-
DCG
12 Pages
-
AX6
10 Pages
-
PLAY
11 Pages
-
ZONING SYSTEM CATALOGUE
20 Pages
Archived catalogs
-
madel
9 Pages
-
DCN circular diffusers
8 Pages