Catalog excerpts
FDS-MINI fire dampers management system The FDS-MINI fire dampers monitoring and control system provides a simple solution for the management of installations with up to 10 dampers. It provides information about the status of the dampers, thereby increasing the safety of the installations. It simplifies maintenance operations in accordance with national legislation and according to the EN 15650 standard, which stip lates that maintenance operations must be performed at standard hich stipulates m st intervals of no greater than 6 months. The unit monitors the status of the dampers by means of LEDs, thereby indicating whether they are open (green) or closed (red) or if there is an anomaly during normal operation or during the maintenance process (flashing). This monitoring facilitates the location of any anomalies that might arise.
Open the catalog to page 1FDS-MINI Wiring g The unit has a potential-free alarm input that receives the alarm signal generated by the fire detection system. If this signal is activated, the dampers move to the safety position (closed). Synchronisation with the fire alarm control panel facilitates maintenance and prevents interruptions to operation of the building by reducing the maintenance time. Contacts Limit switches Maintenance a te a ce Maintenance is performed using a push button on the unit, which activates the maintenance protocol. This maintenance is performed in just a few minutes. The time spent...
Open the catalog to page 2FDS-MINI Technical T h i l specifications ifi ti 24 VAC power supplied externally by a single-phase control switching transformer; insulation and safety in accordance with standards; 1 fire alarm control panel ON/OFF digital input; 1 fan status ON/OFF digital input; 1 standby ON/OFF digital input; 10 open damper indicator limit switches; 10 closed damper indicator limit switches; 10 damper activation voltage outputs; potential-free contact (250 VAC x 6 A); 1 fan ON output; potential-free/voltage-free contact (250 VAC x 6 A); 1 alarm output; potential-free/voltage-free contact (250 VAC x 6...
Open the catalog to page 3All MADEL catalogs and technical brochures
-
WAAB 4-WAY
7 Pages
-
SCC
11 Pages
-
LMT-S
4 Pages
-
MADEL BMC
4 Pages
-
MADEL AMT-AC
6 Pages
-
TEO
3 Pages
-
LOOK
7 Pages
-
KAP
6 Pages
-
TAU
3 Pages
-
UFA
4 Pages
-
LOF&LAIF
6 Pages
-
DXL
4 Pages
-
DBQ
7 Pages
-
SVA-R
6 Pages
-
KSP SUB
2 Pages
-
KCA
2 Pages
-
KRC-PLUS-FREE-COOLING
4 Pages
-
KBY
3 Pages
-
ZMARTBOX
4 Pages
-
FOC-EIS-120
6 Pages
-
FTR
3 Pages
-
FSC-60
3 Pages
-
WAAB-300
46 Pages
-
WAAB-600
46 Pages
-
FBK-EIS-120
11 Pages
-
FOC-EIS-180
6 Pages
-
FOC-EIS-90
5 Pages
-
FOK-EIS-180
6 Pages
-
INTERFACES
1 Pages
-
K1
2 Pages
-
KSP
2 Pages
-
KFC-PLUS
2 Pages
-
KRC-PLUS
2 Pages
-
SKP
3 Pages
-
SKC-C
3 Pages
-
SKC-R
3 Pages
-
SMS
4 Pages
-
SCC
4 Pages
-
SQR
7 Pages
-
CRG
8 Pages
-
RXO
14 Pages
-
AXP
5 Pages
-
AXO
30 Pages
-
FOK-EIS-120
6 Pages
-
SVA-C
3 Pages
-
DCG
12 Pages
-
AX6
10 Pages
-
PLAY
11 Pages
-
ZONING SYSTEM CATALOGUE
20 Pages
Archived catalogs
-
madel
9 Pages
-
DCN circular diffusers
8 Pages