Receptacle Control Solutions For automatic receptacle control in commercial applications Single room Whole floor Whole building PowPak© relay Energi Savr Node™ Switching panel with XP module module • Meet new automatic receptacle control requirements • Controls receptacles and 120V/277V lighting loads from the same device • Easily expand systems by adding Quantum® functionality to control multiple floors, a whole building, or an entire campus Meet requirements: Control Equipment Management Equipment

Open the catalog to page 1
Receptacle Control Solutions Brochure - 2

Understanding the Code Requirements Plug loads are now the third highest contributor to electricity usage in most office buildings, and this is expected to increase as more occupants use personal computers and other electronics. The new codes are designed to automatically reduce electricity use in unoccupied spaces by requiring automatic receptacle control for 50% of the receptacles in commercial buildings. California Title 24 2013 Circuit control is required for 125 V receptacles Applications: private offices, open office areas, reception areas/lobbies, conference rooms, kitchenettes in...

Open the catalog to page 2
Receptacle Control Solutions Brochure - 3

Energy requirements for controlling 50% of the receptacles in commercial buildings can be achieved in two different ways: • plit-wired receptacles (shown in Diagram 1)—one plug on each receptacle is controlled S • uplex receptacle (shown in Diagram 2)—one receptacle within 6 feet of each uncontrolled D receptacle is controlled Diagram 1: Split-wired Duplex Receptacle Junction Box Line/Hot (L) Neutral (N) Neutral (N) Switched Line/Hot 20 A Split-Wired Receptacle 20 A PowPak® relay module* Attention Installer Any receptacles that are controlled by an automatic control device must be marked...

Open the catalog to page 3
Receptacle Control Solutions Brochure - 4

Lutron Receptacle Control Solutions Lutron 20 A receptacle controllers deliver a range of solutions from single circuit to whole building control, to meet both Title 24 2013 and ASHRAE 90.1 2010 requirements. Lutron solutions are also uniquely able to provide both lighting and receptacle control from a single device. Single circuit solution — 20 A PowPak relay module ® Lutron 20 A PowPak relay modules offer wireless control with simple button-press programming. • Junction box mounted wireless controller provides control of one 20 A circuit • Communicates with Lutron occupancy/vacancy...

Open the catalog to page 4
Receptacle Control Solutions Brochure - 5

Panel-based Solution — XP switching module Control up to 48 receptacle or lighting (120V/277 V) circuits with new 20 A XP switching modules. • Control receptacles via wired or wireless occupancy/vacancy sensors or personal controls, or via timeclock scheduling • Lutron patented SoftSwitch® technology extends the average life of the relay • Modules are available for use in standalone XPS or LCP128 systems or as part of XP or CCP utilized in Quantum®

Open the catalog to page 5
Receptacle Control Solutions Brochure - 6

Private Office—20A PowPak® Relay Module Line voltage wiring Low voltage wiring Clear Connect® RF Communication Quantity Description Split-wired duplex receptacle Model Number EcoSystem® H-Series ballast 20 A PowPak relay module PowPak dimming module with EcoSystem Radio Powr Savr™ vacancy sensor, ceiling-mount Radio Powr Savr daylight sensor Pico® wireless control, 3-button with raise/lower Pico wallbox adapter

Open the catalog to page 6
Receptacle Control Solutions Brochure - 7

Sequence of operations Lights • All lights are dimmable • The maximum light level has been set to 80% Occupancy 1 Lights do not automatically turn on when an occupant enters the space; lights must be turned on manually 2 Lights turn off automatically 15 minutes after occupants leave the space 3 Controlled receptacles turn on automatically when an occupant enters the space 4 Controlled receptacles turn off automatically 15 minutes after occupants leave the space Daylight • Lights are controlled by the daylight sensor and automatically brighten and dim to maintain the required light level in...

Open the catalog to page 7
Receptacle Control Solutions Brochure - 8

Single area solution—open office Line voltage wiring Low voltage wiring QS Link Product Clear Connect® RF Communication Quantity Description Duplex receptacle Model Number 20 A Energi Savr Node™ for 0 –10 V Radio Powr Savr™ vacancy sensor, ceiling mount Radio Powr Savr daylight sensor Pico® wireless control, 3-button with Raise/Lower Pico wallbox adapter

Open the catalog to page 8
Receptacle Control Solutions Brochure - 9

Sequence of operations Lights • All lights are dimmable • The maximum light level has been set to 80% Occupancy 1 Lights do not automatically turn on when an occupant enters the space; lights must be turned on manually 2 Lights turn off automatically 15 minutes after occupants leave the space 3 Controlled receptacles turn on automatically when an occupant enters the space. 4 Controlled receptacles turn off automatically 15 minutes after occupants leave the space Daylight • Lights are controlled by the daylight sensor and automatically brighten and dim to maintain the required light level in...

Open the catalog to page 9
Receptacle Control Solutions Brochure - 10

Whole floor solution—XP Panel in Quantum 1 of 4 Line voltage wiring Low voltage wiring Product Panel link QS Link SW1 Clear Connect® RF Communication Quantity Description Duplex receptacle Model Number 24-circuit XP feed-though switching panel Quantum® light management hub with two EcoSystem® loops EcoSystem H-Series ballasts Radio Powr Savr™ vacancy sensor, ceiling mount Radio Powr Savr daylight sensor Pico® wireless control, 3-button with Raise/Lower Pico wallbox adapter

Open the catalog to page 10
Receptacle Control Solutions Brochure - 11

Sequence of operations Lights • All lights are dimmable • The maximum light level has been set to 80% Occupancy (Private Office) 1 Lights do not automatically turn on when an occupant enters the space; lights must be turned on manually 2 Lights turn off automatically 15 minutes after occupants leave the space 3 Controlled receptacles turn on automatically when an occupant enters the space 4 Controlled receptacles turn off automatically 15 minutes after occupants leave the space Timeclock (Open Office) • timeclock is programmed to schedule “working hours” periods and “off hours” periods on a...

Open the catalog to page 11

All LUTRON ELECTRONICS catalogs and technical brochures

  1. myRoom Prime

    3 Pages

  2. brochure_1

    6 Pages

  3. palladiom

    7 Pages

  4. lumaris

    4 Pages

  5. finire

    4 Pages

  6. lutron

    30 Pages

  7. HomeWorks QS

    36 Pages

  8. C?L Dimmers

    4 Pages

  9. Volume 3

    708 Pages

  10. Volume 2

    476 Pages

  11. Volume 1

    234 Pages

  12. Serena

    24 Pages

Archived catalogs

  1. Homeworks

    3 Pages

  2. LCP128

    6 Pages

  3. AURORA

    6 Pages

  4. Power Panels

    48 Pages

  5. Sivoia QED

    32 Pages