Fluorescent ballast and LED driver
51Pages

{{requestButtons}}

Catalog excerpts

Fluorescent ballast and LED driver - 1

Fluorescent ballast and LED driver Selection Guide

Open the catalog to page 1
Fluorescent ballast and LED driver - 2

Lutron® | Table of contents Lutron | Ballasts and drivers Innovation and quality from the world leader in lighting controls Lutron invented the world’s first electronic dimming ballast more than 30 years ago, and continues to lead the industry with innovative and energy-saving fluorescent dimming options. The company offers an extensive selection of ballasts, drivers and controls, providing complete fluorescent and LED dimming solutions. How to use this selection guide The Fluorescent Ballast and LED Driver Selection Guide helps you: • Determine the dimming range required for your...

Open the catalog to page 2
Fluorescent ballast and LED driver - 3

Lutron | Scalable light management solutions Lutron | Scalable light management solutions Solutions for projects of every size The extensive selection of Lutron ballasts, drivers and controls offers a flexible, energy-saving dimming solution Applications Ballasts Available for 1%, 5% and 10% low-end dimming levels, suitable for a variety of applications Compatible with several lamp types including T8 linear and U-bent, T5, T5 HO linear, T5 twin-tube and T4 compact lamps Digitally addressable dimming ballasts available, with easy setup and increased flexibility Factory-tuned ballast factor...

Open the catalog to page 3
Fluorescent ballast and LED driver - 4

Lutron | Understanding Lutron ballasts and drivers Lutron | Understanding Lutron ballasts and drivers Dimming fluorescent light saves energy Lutron quality Fluorescent lighting uses much less power than incandescent lighting. In a typical installation, a 32 W compact fluorescent lamp provides approximately the same light output as a 100 W incandescent lamp. As both sources are dimmed, fluorescent lamps continue to be more energy efficient. Superior components Extending lifetime Lutron ballasts and drivers are manufactured to the highest level of quality, using carefully selected components....

Open the catalog to page 4
Fluorescent ballast and LED driver - 5

Lutron® | Understanding Lutron ballasts and drivers Measured light vs. perceived light The human eye responds to low light levels by enlarging the pupil, allowing more light to enter the eye. This response results in a difference between measured and perceived light levels. A lamp that is dimmed to 10% of its maximum measured light output is perceived as being dimmed to only 32%. Likewise, a lamp dimmed to 1% is perceived to be at 10%. Selecting a Lutron ballast or driver Lutron offers several ballast and driver families that have various dimming levels and control options to suit any...

Open the catalog to page 5
Fluorescent ballast and LED driver - 6

Lutron® | Energy-saving strategies Energy-saving control strategies Personal control Provide personal choice and control of light levels to accommodate different tasks and activities. Permit control from multiple locations. Occupancy/vacancy sensing Gradually dim lights to a low level or turn lights off when space is unoccupied; turn lights on when someone enters. Daylight harvesting Dim electric light or switch it off during the day to take advantage of available daylight. High-end trim Set the maximum light level in a space based on customer preference or design requirements. Typical...

Open the catalog to page 6
Fluorescent ballast and LED driver - 7

Lutron® | Control options Lutron | Control options Lutron ballast and driver control options In addition to offering ballasts and drivers with different low-end dimming levels, Lutron offers a variety of control options. 3-Wire 3-Wire control is a line-voltage phase control dimming method that communicates the dimming signal through a wire called Dimmed Hot. Available for: Hi-lume A-Series LED drivers Available for: • Tu-Wire ballasts

Open the catalog to page 7
Fluorescent ballast and LED driver - 8

Lutron® | System compatibility System compatibility is based on the available control Control systems compatible with EcoSystem digital linktype for each ballast and driver family ballasts and drivers Control type Interface required for compatibility. PowPak dimming module with EcoSystem The PowPak dimming module with EcoSystem is a load controller that allows for easy integration of digital lighting loads with wireless occupancy and daylight sensors as well as wireless controls. It uses Lutron EcoSystem technology in intelligent fluorescent and LED lighting control solutions, creating...

Open the catalog to page 8
Fluorescent ballast and LED driver - 9

Ballasts and drivers | Ballasts and drivers Fluorescent and LED lighting is used widely in educational, institutional and commercial buildings. They meet energy-conscious design criteria such as ASHRAE/IESNA 90.1 standards and LEED® guidelines. Fluorescent and LED lighting is also increasingly found in residential spaces, especially in recessed downlights and coves. Dimming fluorescent lighting instead of repeated switching helps maintain lamp life and also saves energy. All Lutron® fluorescent dimming ballasts and LED drivers are 100% performance-tested at the factory and come with a...

Open the catalog to page 9
Fluorescent ballast and LED driver - 10

Ballasts and drivers | Quick reference guide Ballasts and drivers | Quick reference guide EcoSystem® compatible ballasts and drivers Compatible Lamp Types and Wattages Input Voltage Control Options Available Case Types (pg. 20) Low-end dimming level Integral Sensor Connections Fluorescent ballasts

Open the catalog to page 10
Fluorescent ballast and LED driver - 11

3-Wire and Tu-Wire® compatible ballasts (For other 3-wire compatible ballasts, see pgs 16-17) Integral Low-end Sensor Family Compatible Lamp Types and Wattages Input Voltage Control Options Available Case Types (pg. 20) dimming level Connections

Open the catalog to page 11
Fluorescent ballast and LED driver - 12

Ballasts and drivers | Quick reference guide Ballasts and drivers | Quick reference guide Case dimensions Case dimensions 8-32 Threaded stud 0.29 in (7.37 mm) long 8-32 Threaded stud 0.29 in (7.37 mm) long F D Note: otted area for sensor attachment applies D to EcoSystem® J-case only. Lamp wires are 36 in (0.90 m) for leaded models D Power and control wires are 18

Open the catalog to page 12
Fluorescent ballast and LED driver - 13

Ballasts and drivers | Quick reference guide Ballasts and drivers | Quick reference guide Case dimensions Case dimensions K-case (Ballast) For studded models only: H 1.09 in (28 mm) I 2.00 in (51 mm) J 1.60 in (41 mm) F E D 8-32 Threaded stud 0.29 in (7.37 mm) long P-case (International models only) A 31.8 mm A 31.8 mm B 90 mm mm B 90.0 C 154.7 mm C 154.7 mm D 134.6 mm D 134.6 mm E 13.6 mm E 13.6 mm F 6.95 mm F 6.95 mm G 76.05 mm G 76.05 mm Mounting centers For studded models only: H 1.09 in (28 mm) I 2.00 in (51 mm) J 1.60 in (41 mm) For non-studded models only: S 1.38 in (35 mm) T 0.64 in...

Open the catalog to page 13

All LUTRON ELECTRONICS catalogs and technical brochures

  1. myRoom Prime

    3 Pages

  2. brochure_1

    6 Pages

  3. palladiom

    7 Pages

  4. lumaris

    4 Pages

  5. finire

    4 Pages

  6. lutron

    30 Pages

  7. HomeWorks QS

    36 Pages

  8. C?L Dimmers

    4 Pages

  9. Volume 3

    708 Pages

  10. Volume 2

    476 Pages

  11. Volume 1

    234 Pages

  12. Serena

    24 Pages

Archived catalogs

  1. Homeworks

    3 Pages

  2. LCP128

    6 Pages

  3. AURORA

    6 Pages

  4. Power Panels

    48 Pages

  5. Sivoia QED

    32 Pages