Soraa SLE11 Module
14Pages

{{requestButtons}}

Catalog excerpts

Soraa SLE11 Module - 1

SORAA LED Optical Light Engine GaN-on-GaN™ Technology Features Soraa Point Source Optics™ Exceptional beam control from 9 degrees narrow spot to 36 degrees flood with smooth uniform light distributions Soraa VP3 Vivid Color™ and VP3 Natural White™ Accurate color rendering and white rendering based on light emission across the full visible range from 400nm to 700nm Soraa SNAP System™ Compatible Narrow spot versions compatible with Soraa SNAP for flexible light distribution adjustment and white point change Integrated Temperature Sensor Reference point temperature readout enables in situ, in fixture temperature assessment Qualification UL8750 recognized CE, RoHS Projected Lifetime 50,000 hours to L70 and color stability based on CCT, at specified operating conditions. Projections based on LM-80 testing. - 2700K – 0.007 du’v’ - 3000K – 0.007 du’v’ - 4000K – 0.009 du’v’ - Typical du’v’ within field angle = 0.006 - Typical dCCT within the field angle (2700K and 3000K) =150K - Typical dCCT within the field angle (4000K) = 250K Note: This specification sheet covers both SLE (with heatsink) and SLC (without heatsink) products. The nomenclature SLx is used to identify both SLE and SLC products. Please consult the Application Guide for details on SLC opera

Open the catalog to page 1
Soraa SLE11 Module - 2

Reference Number Notes: 1. At 25°C ambient for 50,000 hour life 2. Beam angle defined at 50% of peak intensity 3. Field angle defined at 10% of peak intensity 4. For other drive currents and conditions, consult the Application Guide

Open the catalog to page 2
Soraa SLE11 Module - 3

1. At 25°C ambient for 50,000 hour life 2. Beam angle defined at 50% of peak intensity 3. Field angle defined at 10% of peak intensity 4. For other drive currents and conditions, consult the Application Guide

Open the catalog to page 3
Soraa SLE11 Module - 4

1. At 25°C ambient for 50,000 hour life 2. Beam angle defined at 50% of peak intensity 3. Field angle defined at 10% of peak intensity 4. For other drive currents and conditions, consult the Application Guide 5. NOTE THAT THESE LIGHT ENGINES USE THE LARGER SLE30 HEATSINK WITH THE SLC16 LIGHT CUP

Open the catalog to page 4
Soraa SLE11 Module - 5

1. At 25°C ambient for 50,000 hour life 2. Beam angle defined at 50% of peak intensity 3. Field angle defined at 10% of peak intensity 4. For other drive currents and conditions, consult the Application Guide

Open the catalog to page 5
Soraa SLE11 Module - 6

Notes: 1. Forward voltage depends on drive current and temperature. For driver selection a supportable range of 20V to 35V is recommended. 2. Dimming can be achieved with Pulse Width Modulation and Current Amplitude Modulation or a combination of both. Notes: 1. These charts can be applied to SLExx/SLCxx-08 by multiplying current by 2; and to SLE30/SLC30-04 by dividing current by 2.

Open the catalog to page 6
Soraa SLE11 Module - 7

Reference Temperature Readout Notes: 1. Tolerance: +/- 5°C 2. Temperature can be assessed with an NTC next to the LED on the mounting board inside the Light Engine. See figure 1.1 for example. Individual Color Rendering Index Notes: 1. At 70°C reference point temperature, 300mA for SLE16-06-xxx and SLE11-06-xxx and 600mA for SLE30-08-xxx and SLE16-08-xxx.

Open the catalog to page 7
Soraa SLE11 Module - 8

Notes: 1. CQS color samples, charts in La'b' 2. At 70°C reference point temperature, 300mA for SLE16-06-xxx and SLE11-06-xxx and 600mA for SLE30-08-xxx and SLE16-08-xxx.

Open the catalog to page 8
Soraa SLE11 Module - 9

Spectral Power Distributions 95 CRI Notes: 1. At 70°C reference point temperature, 300mA for SLE16-06-xxx and SLE11-06-xxx and 600mA for SLE30-08-xxx and SLE16-08-xxx.

Open the catalog to page 9
Soraa SLE11 Module - 10

Narrow Spot 4 Degree Narrow Spot 9 & 10 Degree Narrow Flood 25 Degree Notes: 1. Beam plots for 3,000K 95CRI 2. At 70°C reference point temperature, 300mA for SLE16-06-xxx and SLE11-06-xxx and 600mA for SLE30-08-xxx and SLE16-08-xxx.

Open the catalog to page 10
Soraa SLE11 Module - 11

Bottom View V+ ( Goes t o Red) V- ( Goes t o Black) NT C Read-out, non polariz Notes: 1. Drawings not to scale, different scales used 2. Dimensions in mm Bottom View Wire Outline Bottom View * Wire Tickness: 2mm * Total Wire Length: 430mm

Open the catalog to page 11
Soraa SLE11 Module - 12

Bottom View Bottom View Bottom View Wire Outline 30mm Copper V+ ( Goes t o Red) V- ( Goes t o Black) NT C Read-out, non polariz Notes: 1. Drawings not to scale, different scales used 2. Dimensions in mm * Wire Tickness: 2mm * Total Wire Length: 430mm

Open the catalog to page 12
Soraa SLE11 Module - 13

Bottom View Bottom View Bottom View Bottom View Wire Outline V+ ( Goes t o Red) V- ( Goes t o Black) NT C Read-out, non polariz Notes: 1. Drawings not to scale, different scales used 2. Dimensions in mm * Wire Tickness: 2mm * Total Wire Length: 430mm

Open the catalog to page 13
Soraa SLE11 Module - 14

Soraa Inc. - Americas HQ 6500 Kaiser Drive, Suite 110, Fremont, CA 94555 United States Tel: 855 GO-SORAA / 855 467-6722 Soraa Inc. - International HQ Unit 1, Chelsing House, Mead Lane, Hertford, Hertfordshire. SG13 7AW United Kingdom Tel: +44 (0)1992 535053 www.soraa.com Information and specifications subject to change. Light Engine HS Rev 3 03.16.16

Open the catalog to page 14