cad

Z8

Z8
1 / 96 PagesView full catalog

Z8

Product catalog summary
Technical Document Summary
1. Applications
The document outlines various applications for submersible motors and pumps, including water supply from deep wells, pressure boosting, firefighting, irrigation, and mining.
2. Specifications
Key specifications include delivery up to 180 m3/h, head up to 550 m, maximum pump diameter of 198 mm, and motor power ranging from 5.5 to 150 kW. The motors are designed for a maximum immersion depth of 350 m and can handle a maximum sand content of 100 g/m3.
3. Motor Details
Motors are rewindable three-phase with water-filled winding, operating at 380-415 V, 50 Hz. They are designed for horizontal installation with a maximum of 15 starts per hour for certain models.
4. Construction Features
Components are made of stainless steel for corrosion resistance, with guide bearings and wear rings for durability. NEMA standard dimensions are followed, with optional DUPLEX stainless steel versions available.
5. Optional Features and Accessories
Optional features include different voltages, high-temperature versions, and accessories like coupling flanges, panels, cables, and splices.
6. Materials
Various stainless steel grades and materials like NBR, POM, and PTFE are used, ensuring durability and reliability.
7. Hydraulic Performance
Performance tables are provided for different series and stages, valid for liquids with a density of 1.0 Kg/dm3 and viscosity of 1 mm2/sec.
8. Dimensions and Weights
Specific dimensions and weights for each pump type and stage are detailed, with considerations for non-return valve and cable configurations.
9. Operating Characteristics
Three-phase motors operate at 380-415 V, 50 Hz, with maximum supply voltage variations of ±10%. Horizontal operation is possible with correct axial thrust management.
10. Special Versions
Special versions include motors with double cable outlets for star/delta start and series made of AISI 316 and Duplex stainless steel for high-temperature environments.
11. Control Panels
Specifications for three-phase electric panels include supply voltage, frequency, protection class, and optional accessories for enhanced monitoring and control.
12. Technical Appendix
Includes data on suction loss at various elevations, vapour pressure and density of water, flow resistance in pipelines, and conversion tables for volumetric capacity and pressure.
13. Product Selection and Company Overview
Xylect software aids in pump solution selection, and Xylem is highlighted as a global water technology company with expertise in water management.
See more

Catalog excerpts

Z8-2

HYDRAULIC PERFORMANCE RANGE AT 50 Hz

 Open the catalog to page 2
Z8-5

SECTORS AGRICULTURAL, INDUSTRIAL. APPLICATIONS APPLICATIONS • Water supply from deep wells. • Pressure boosting and water distribution in civil and industrial systems. • Supply of surge tanks and reservoirs. • Firefighting and washing systems. • Water level control. • Irrigation. • Mining. SPECIFICATIONS SPECIFICATIONS PUMP Delivery: Delivery up to 180 m3/h. Head: Head up to 550 m. Maximum pump overall diameter (2 cable covers included): 198 mm for all versions. • Maximum electric pump immersion depth: 350 m with L6W, L8W, L10W motors. • Maximum permissible quantity of suspended sand: 100 g/m3....

 Open the catalog to page 5
Z8-6

TABELLA MATERIALI Z8 MATERIALS TABLE OF MATERIALS Z8 COMPONENT MATERIAL EUROPE Delivery head / Valve Casing Valve Valve seat Valve spring Diffuser / Bowl Diffuser O-Ring Impeller Taperlock Wear ring Lower support / Suction Casing Suction strainer Pump shaft Coupling Bearing bush Thrust Bearing Screw, stud, nut Cable protection Stainless steel Stainless steel NBR 90 Stainless steel Stainless steel NBR 70 Stainless steel Duplex stainless steel POM (DELRIN ®) Stainless steel Stainless steel Stainless steel Stainless steel EPDM + LOXAMID ® PTFE + 25% carbon Stainless steel Stainless steel TABELLA...

 Open the catalog to page 6
Z8-7

HYDRAULIC PERFORMANCE RANGE AT 50 Hz

 Open the catalog to page 7
Z8-8

STAGES Z855 SERIES, 1 TO 7 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z855 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z855 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce...

 Open the catalog to page 8
Z8-9

The flow resistance of the non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 9
Z8-10

STAGES Z855 SERIES, 8 TO 19 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z855 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z855 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6W motor. C = 201,5 mm with L8W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension...

 Open the catalog to page 10
Z8-11

The flow resistance of the non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 11
Z8-12

STAGES Z875 SERIES, 1 TO 6 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z875 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP 15 42 70 90 105 0 H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z875 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension A by 110...

 Open the catalog to page 12
Z8-13

The flow resistance of the non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 13
Z8-14

STAGES Z875 SERIES, 7 TO 18 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z875 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z875 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6W motor. C = 201,5 mm with L8W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension...

 Open the catalog to page 14
Z8-15

The flow resistance of the non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 15
Z8-16

STAGES Z895 SERIES, 1 TO 6 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z895 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z895 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6W motor. C = 201,5 mm with L8W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension...

 Open the catalog to page 16
Z8-17

The flow resistance of the AHv non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 17
Z8-18

STAGES Z895 SERIES, 7 TO 18 STAGES TABELLA DI PRESTAZIONI IDRAULICHE SERIE Z895 2 poli 50 Hz OPERATING CHARACTERISTICS AT OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP H = TOTAL HEAD METRES COLUMN OF WATER DIMENSIONI E PESI SERIE Z895 2 poli 50 Hz DIMENSIONS AND WEIGHTS ELECTRO 1) Max electric pump diameter with 2 motor cables included. In case of 1 motor cable C = 201,5 mm with L8W motor. C = 236 mm with L10W motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension...

 Open the catalog to page 18
Z8-19

The flow resistance of the AHv non-return valve has been considered. These performances are valid for liquids with density p = 1.0 Kg/dm3 and kinematic viscosity v = 1 mm2/sec.

 Open the catalog to page 19

Archived catalogs

  1. GLS-GLV

    84  Pages

  2. DIGGER

    3  Pages

  3. GL-GLV

    3  Pages

  4. DL

    7  Pages

  5. DOMO GRI

    6  Pages

  6. DOMO

    11  Pages

  7. DN

    4  Pages

  8. DIWA

    5  Pages

  9. DOC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.