
Starlike® Pro Technical Specifications Decorative epoxy gel (6Gen) based on scientific research and enhanced with polymerised coloured quartz; waterproof, stain-resistant and UV-resistant, for the installation and grouting of joints from 1 to 20 mm with high hygiene standards, for all types of mosaics, tiles, porcelain stoneware, large slabs, marble, granite and natural stone. The Original. Product description Decorative epoxy gel (6th generation) for grouting joints from 1 to 20 mm in all types of mosaics, tiles, porcelain stoneware, large-format slabs, marble, granite and natural stone. Patented formula enhanced with exclusive Level 3 technology using coloured quartz microspheres, which guarantees colour fastness, uniformity and total colour stability. For waterproof, stain-resistant and UV-resistant grout with exceptional chemical and mechanical resistance and resistance to thermal shock. Designed for exceptional ease of application and, thanks to state-of-the-art features, the mixture is extremely creamy, light, and super easy to spread and clean up. Classified as RG – EN 13888 and R2T – EN 12004 Starlike® Pro is a highly innovative Litokol invention protected by Patents No. 102006901436703 – No. 102028000005366 Part A Blend of epoxy resins of varying molecular weights under our own licence High density of polymerised coloured quartz microspheres ~200 million/kg High-concentration recycled glass microbeads ~85 million/kg Ultra-fine particle size – range 60–200 µm Rheological stabilisers and smart flow enhancers
Open the catalog to page 1Part B Latest-generation non-corrosive polymeric linker Starlike® Pro embodies Litokol’s ongoing scientific progress. It is designed using innovative raw materials to improve the installation experience, enhance safety and reduce environmental impact. Engineered with Colour technology Level 3 Colour Quartz Microsphere® technology Level 2 Recycled Crystal Microsphere® technology Zherorisk® EpoxyGel technology Defender Anti-Microbial Technology Contains 200 million quartz microspheres per kg Microsphere diameter: 60 to 200 µm Polymeric microsphere coating Wet-suspension pigmentation Contains 85...
Open the catalog to page 2Chemistry + Smart Free from oxirane. Does not contain C12-C14 (oxirane, mono- Not hazardous to the applicator Not hazardous to the environment Not hazardous for transport - ADR-compliant Non-corrosive and non-toxic Complies with ISO 22196 - Antimicrobial protection: prevents the growth of bacteria and mould on the surface. Complies with HACCP/Regulation (EC) No 852/2004 on food hygiene Contains recycled glass microspheres (>10%) EPD Environmental Product Declaration LCA results for Global Warming Potential - Greenhouse Gases (GWP-GHG) Impact category Unit A1-A3 C1 C2 C3 C4 D Materials Ceramic...
Open the catalog to page 3Self-levelling compounds Plaster Plasterboard Plaster and anhydrite Existing tiles Radiant heating systems Waterproofing products Decoupling membranes Metal Wood Aerated concrete Fibre-cement sheets Concrete Uses Grout - adhesive Floors - walls Interior - exterior Radiant heating systems Facades Swimming pools - fountains SPA - Hammam Terraces - balconies Indoor wet areas - bathrooms and showers Exclusive locations Industrial flooring Dairies, abattoirs, food processing industries Residential, public, commercial and street furniture Approved for marine use in accordance with the MED Directive...
Open the catalog to page 4Flexural strength at 7 days > 1000 psi 5.7 Resistance to thermal shock > 500 psi 5.8 Compliance Abrasion resistance Compressive strength after 28 days Flexural strength after 28 days Shrinkage Water absorption after 240 minutes Compliance Shear adhesion after immersion in water Shear adhesion after thermal shocks Open time Initial shear adhesion Chemical resistance ApplicationSpecifications Mixing ratio Mixing ratio Consistency of the mix Specific gravity of the mixture Pot life Joint width Application Permissible application temperatures Drying time for grouting Ready for foot traffic Commissioning...
Open the catalog to page 5please refer to the product calculator available on the website www.litokol.com Use as grout Check that the adhesive gel has fully set and is dry. The joints must be dry, clean, free from dust and empty for at least twothirds of the tile thickness. Any adhesive that may have spilled during installation must be removed whilst still fresh. Use as an adhesive In accordance with standard UNI 11493-1, substrates must be mechanically sound and free from crumbly parts, grease, oil, paint, wax and rising damp. Cement-based plasters must be allowed to cure for at least one week per centimetre of thickness....
Open the catalog to page 6To ensure the gel adheres perfectly to the substrate, apply a thin, even coat of the mixture using the smooth side of the trowel and, immediately afterwards, apply the desired thickness using the notched side. The notching of the trowel must be chosen according to the size of the material to be laid and the substrate. In accordance with the UNI 11493-1 standard, use the double-coating technique, applying the gel to the back of the tiles as well to ensure they are fully wetted, for outdoor installations or in areas subject to particularly high stress. To ensure complete transfer of the gel to...
Open the catalog to page 7More stubborn marks can be removed with Starlike® Care Pro epoxy resin cleaning gel even several days later, whilst older product residues must be removed with Starlike® Remover epoxy residue cleaning gel. Technical Specifications
Open the catalog to page 8For the elastic sealing of expansion joints, partition joints and perimeter joints, use sealants from the Pixel 3D range. For the correct maintenance and protection of surfaces, use the specific Litokol cleaning products from the X-Cleaner range. Given the variations in quality across global ceramic production (e.g. polished porcelain stoneware), the wide range of morphological types of marble and natural stone, and the different compositions used in the manufacture of mosaics available on international markets, it is recommended that a preliminary grouting test be carried out to identify any...
Open the catalog to page 93 Pages
3 Pages
3 Pages
3 Pages
3 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
8 Pages
3 Pages
4 Pages
4 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
4 Pages
6 Pages
2 Pages
2 Pages
4 Pages
4 Pages
7 Pages
7 Pages
6 Pages
8 Pages
10 Pages
8 Pages
7 Pages
3 Pages
4 Pages
5 Pages
4 Pages
5 Pages
4 Pages
6 Pages
3 Pages
1 Page
9 Pages
9 Pages
4 Pages
8 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
10 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
8 Pages
10 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
8 Pages
12 Pages
8 Pages
10 Pages
6 Pages
5 Pages
6 Pages
13 Pages
5 Pages
13 Pages
12 Pages
7 Pages
10 Pages
6 Pages