SafetyGel® Technical Specifications Continuous, watertight, crack-resistant elastic gel membrane for the waterproofing of swimming pools, terraces, balconies and showers, and for the prevention of cracks when laying tiles of all types and sizes, as well as natural stone. Formula based on 6-Dimensional Elasticity technology, for which an international patent application has been filed. Waiting time between the 1st and 2nd coats: 2 hours. Waiting time before fitting the cladding: 2 hours. Product description Continuous, watertight, crack-resistant elastic gel membrane for the waterproofing of swimming pools, terraces, balconies and showers, and for the prevention of cracks when laying tiles of all types and sizes, as well as natural stone. Formula based on 6-Dimensional Elasticity technology, for which an international patent application has been filed. Ready to use, quick-drying (rainproof in 2 hours), requires no reinforcement mesh, tapes or strips for waterproofing corners and edges. It is easily applied with a roller, brush, smooth steel trowel or airless sprayer, creating a continuous, joint-free barrier for waterproofing swimming pools, outdoor areas and damp environments; it also acts as an elastic, crack-bridging membrane for sealing cracks, offering exceptional tensile adhesion thanks to its latest-generation gel properties enhanced with polymerised quartz microspheres. It guarantees structural adhesion even on non-absorbent substrates such as old tiles, fibreglass, PVC, metal and wood. Classified as DM 02 P – EN 14891 SafetyGel® combined with PowerGel® S1+ forms the High-Adhesion AntiFracture System – TileSafe® System, engineered for the installation of largeformat tiles and slabs of any type and size in high-traffic areas, even on cracked substrates (up to 3 mm). The elastic system helps to dissipate and neutralise movements in the substrate and expansion of the cladding, whilst distributing heavy loads Technical Specific
Open the catalog to page 1evenly without causing stress. TileSafe® System is a highly innovative Litokol invention protected by patent application no. 102025000025363 Gel formula with an international patent application filed SafetyGel® is a highly innovative Litokol invention with an international patent application filed under No. 102025000025348. Elastomeric gel with a proprietary blend of polymer resins 3D structure with polymerised quartz microspheres and inorganic microfillers Reinforced with natural lamellar magnesium silicates Hydrophobic protective booster based on reactive groups with a weatherproofing action...
Open the catalog to page 2Continuity. SafetyGel® is engineered using 6-dimensional elasticity technology, which ensures perfect adhesion even on uneven or difficult surfaces, such as cracked flooring or complex structures, guaranteeing longlasting elasticity and flexibility, even at joints and 90° angles. It has no joints because the gel self-cures at joints or connections through a chemical process in which the material’s molecules bond together to form a three-dimensional covalent network. The continuous gel membrane thus provides uninterrupted protection, eliminating any vulnerable points that might develop around...
Open the catalog to page 32. PowerGel® S1+ – a smart, elastic, crack-resistant tri-polymer gel, enhanced with Crack Prevention® technology, capable of protecting the internal bond area from micro-cracks and mechanical stress. Acts as a smart structural interface, protecting the adhesive transition zone (ITZ) and promoting a flexible, long-lasting bond. Together, these two elements form an active integrated system that works by adhesion: the interaction between the two technologies drastically reduces stress concentration, prevents the vertical and lateral propagation of micro-cracks and increases the mechanical durability...
Open the catalog to page 4Gel Performance Damping Membrane Safety gel membrane with uniform load distribution 100% pure gel in H₂O phase Does not contain solvents or plasticisers It does not contain cement or acetic polymers Not hazardous to the applicator Not hazardous to the environment Not hazardous for transport – ADR-compliant Non-corrosive and non-toxic Continuous system free from rubber, plastic and PVC (rolls, membranes and tapes) Ready to use, reusable, minimises waste and material wastage Retains elasticity and all performance characteristics even after being reopened and reused Improves resource efficiency...
Open the catalog to page 5Screeds Self-levelling compounds Levelling Compounds Plaster and skim coats Existing tiles Radiant heating systems Concrete and reinforced concrete Plasterboard Plaster and anhydrite Fibre-cement sheets Wood and engineered wood panels Metals Plastics and PVC Fibreglass Lightweight panels Existing cement-polymer waterproofing products Interior – exterior Floors – walls Overlay Indoor wet areas, bathrooms and showers Swimming pools and fountains Terraces and balconies SPA and Hammam Facades Industrial flooring Residential, public, commercial and street furniture Areas subject to heavy footfall...
Open the catalog to page 6TechnicalSpecifications installation and for 72 hours after application Apply the finish to the membrane within 72 hours in external applications to avoid prolonged exposure to ultraviolet rays; alternatively, cover with sunshade sheets; in applications exposed to traffic and abrasion, cover with suitable protection systems against direct abrasion until the finish is applied Do not apply to wet surfaces, damp substrates (> 3% relative humidity) or those subject to rising damp Do not apply in thicknesses > 1 mm per coat Do not apply if there is condensation on the surfaces Do not apply to uneven...
Open the catalog to page 7Dimensional stability Waterproof after 48 hours Cut resistance on concrete For porcelain stoneware Initial adhesion after 7 days Adhesion after immersion Initial bond strength after 28 days Initial bond strength after 12 weeks Adhesion after immersion in water for 100 days Growth of mould, fungi and microorganisms Shear strength on tiles Initial adhesion after 7 days Adhesion after immersion in water Initial bond strength after 28 days Adhesion after ageing Point load test Insulation against cracks (openings) Preparation of the gel mixture pH of the mixture Specific gravity of the mixture Total...
Open the catalog to page 83 Pages
3 Pages
3 Pages
3 Pages
3 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
8 Pages
3 Pages
4 Pages
4 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
4 Pages
6 Pages
2 Pages
2 Pages
4 Pages
4 Pages
7 Pages
7 Pages
6 Pages
8 Pages
10 Pages
8 Pages
7 Pages
3 Pages
4 Pages
5 Pages
4 Pages
5 Pages
4 Pages
6 Pages
3 Pages
1 Page
9 Pages
9 Pages
4 Pages
8 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
10 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
8 Pages
10 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
8 Pages
12 Pages
8 Pages
10 Pages
6 Pages
5 Pages
6 Pages
13 Pages
5 Pages
13 Pages
7 Pages
10 Pages
12 Pages
6 Pages