Ottoseal S125 SINGLE-COMPONENT ALCOHOL-BASED GROUT. FOR INTERIORS AND EXTERIORS. ZHERORISK TECHNOLOGY OFFERS VERY LOW VOLATILE ORGANIC COMPOUND EMISSION RATE. Single-component silicone- and alkoxy-based neutral cross-linking grout. ADVANTAGES / FEATURES • Product exhibiths Very low volatile organic compound (VOC). Complies with the most stringent Global Air Quality Regulations. • Excellent resistance to weathering, aging and UV rays • Resistant to mold and bacteria • Ready to use • Flexibility • Non-corrosive 10.4 U.S. oz. (310 ml) cartridge (boxes with 20 pcs) Floor joints and connection joints for plastic and design joints in rubber, linoleum, vinyl and PVC. Expansion joints and connection joints in sanitary areas. For the external sealing of mirrors in combination with materials, such as ceramic, metal, glass, etc. Sealing of connection joints on windows and doors in wood, metal and plastic. Sealing of facades, parapets, roller shade cassettes and metal construction elements. Expansion joints or connection joints for pre-fabricated cement. The surfaces to be grouted or bonded must be perfectly clean, dry and free of dust, grease, oil and old paint. Cleaning non-porous surfaces: clean with OTTO Cleaner T (drying time about 1 minute) and a dry fiber-free cloth. Cleaning porous surfaces: clean the surfaces mechanically, e..g with a steel brush or a smoothing disc to remove loose particles. Remove the top part of the threaded part of the cartridge, screw in the plastic nozzle and cut it to the right angle depending on the desired diameter and profile. Insert the cartridge in a manual or air gun (with telescopic piston) and extrude the adhesive grout, being careful to avoid the entrainment of air. Once opened, the packages must be used in a relatively short time. The ideal operating temperature for the substrate and grout is between 59°F (15°C) and 77°F (25°C). The joints must be finished within the grout open time. Avoid contact with solvents during cross-linking. given the large number of factors which influence the treatment and the application of the product, the user should always perform a test treatment and application. • Spread the product at temperatures between 40°F and 95°F • In warm climates, keep the packaged product in a cool and dry place away from the sun before use • Prima di applicare il prodotto è necessario assicurarsi che i materiali costruttivi con i quali si verrà a contatto siano compatibili con il prodotto stesso e tra loro e che non possano danneggiare o alterare le caratteristiche del prodotto • In the case of construction materials that will subsequently be worked at the point where the product has been applied, the user must verify that the solid or volatile components to be used does compromise or alter the
Open the catalog to page 1characteristics of the product - Where necessary, the user must contact the manufacturer of the building materials used • During setting, minimal quantities of alcohol are slowly released • During application and setting, good ventilation is required • The vulcanization times vary depending on the thickness of the silicone joint • Single-component silicones are not suitable for full-surface bonding, except for specific construction requirements • If the silicone grout needs to be applied in a layer over 5/8" (15 mm), please call our technical help service first • Avoid contact with bituminous...
Open the catalog to page 2NOT SUITABLE RECOMMENDED TEST Linear meters of joint that can be obtained with a 310 ml cartridge Width Width Width Width 1/4" (6 mm) 8 mm (0.31in) 10 mm (0.39 in) 15 mm (0.59in) ± 10 m (32.8 ft) ± 8 m (26.25 ft) ± 6 m (19.68 ft) ± 6 m (19.68 ft) ± 4.5 m (14.76 ft) ± 3 m (9.84 ft) ± 3 m (9.84 ft) ± 2 m (6.56 ft) ± 1.5 m (4.92 ft) ± 1 m (3.28 ft) IDENTIFICATION DATA Polymerization Consistency of mix Specific gravity Film-forming time Setting in 24 hours Acceptable application temperatures Recommended application temperatures Serviceability Temperatures Set to light foot traffic Ready for use APPLICATION...
Open the catalog to page 3Powered by TCPDF (www.tcpdf.org) COLOR TABLE Data detection at temperature +73.4°F (+23 °C ), R.H. 50% and with no wind. May vary depending on the specific conditions of the installation site. Form n. 815 Revision n. 0 Date: March 2021 The information and provisions contained in this technical data sheet reflect our best experience. Given the impossibility of directly intervening on the conditions of the work site and execution of the works, they represent indications of a general nature, which are in no way binding on our Company. It is therefore advisable to perform a spot test to check the...
Open the catalog to page 424 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
6 Pages
6 Pages
5 Pages
6 Pages
7 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
5 Pages
4 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
4 Pages
6 Pages
6 Pages
3 Pages
2 Pages
4 Pages
2 Pages
3 Pages
6 Pages
2 Pages
2 Pages
2 Pages
5 Pages
3 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
7 Pages
3 Pages
3 Pages
3 Pages
2 Pages
8 Pages
3 Pages
3 Pages
3 Pages
3 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
5 Pages
5 Pages
5 Pages
7 Pages
7 Pages
8 Pages
3 Pages
5 Pages
7 Pages
7 Pages
10 Pages
6 Pages
6 Pages
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
9 Pages
9 Pages
7 Pages
11 Pages
100 Pages
4 Pages
2 Pages
17 Pages
21 Pages
34 Pages
100 Pages
25 Pages
2 Pages
113 Pages
12 Pages