Ottoseal S117 SINGLE-COMPONENT NEUTRAL CROSS-LINKING GROUT. FOR INTERIORS AND EXTERIORS. ZHERORISK TECHNOLOGY OFFERS VERY LOW VOLATILE ORGANIC COMPOUND EMISSION RATE. Single-component silicone- and oxime-based, neutral cross-linking grout, free from methylethyl ketone oxime. Does not cause corrosion (rust) on unprotected metal surfaces. ADVANTAGES / FEATURES • Product with very low volatile organic compound (VOC) emission rate, compliant with class A+ (Émission dans l’air intérieur – French Regulations) • Excellent resistance to weathering, aging and UV rays • Resistant to mold and bacteria • Ideal for wall coverings • Flexibility • Non-corrosive • Ready to use • No restrictions for transport over road, sea, air and rail • Suitable for natural stone 10.4 U.S. oz. (310 ml) cartridge (boxes with 20 pcs) Sealing of marble and all natural stone, e.g. sandstone, quartz, granite, gneiss, porphyry, etc. in interiors and exteriors. Sealing of expansion joints on walls and facades. The surfaces to be grouted or bonded must be perfectly clean, dry and free of dust, grease, oil and old paint. Cleaning non-porous surfaces: clean with OTTO Cleaner T (drying time about 1 minute) and a dry fiber-free cloth. Cleaning porous surfaces: clean the surfaces mechanically, e..g with a steel brush or a smoothing disc to remove loose particles. Remove the top part of the threaded part of the cartridge, screw in the plastic nozzle and cut it to the right angle depending on the desired diameter and profile. Insert the cartridge in a manual or air gun (with telescopic piston) and extrude the adhesive grout, being careful to avoid the entrainment of air. Once opened, the packages must be used in a relatively short time. The ideal operating temperature for the substrate and grout is between 59°F (15°C) and 77°F (25°C). The joints must be finished within the grout open time. Avoid contact with solvents during cross-linking. In the case of non-polished natural stone in particular, take care not to soil the areas around the joint because the product residue is difficult to remove. Especially in the case of sensitive, rough and absorbent natural stone surfaces, such as sandstone and limestone, it is recommended to apply an adhesive on the edges of the joints to prevent the seal from being pressed into the surface of the natural stone during polishing. This may cause stains which may not be able to be removed afterwards. Dust deposits on silicone residue can cause further impurities. It is not recommended to use other commonly commercially available smoothing products (e.g. soap detergents) given the tendency to form stains of typical some types of more delicate marble and natural stone. given the large number of factors which influence the treatment and the application of the product, the user should
Open the catalog to page 1always perform a test treatment and application. • Spread the product at temperatures between 40°F and 95°F • In warm climates, keep the packaged product in a cool and dry place away from the sun before use • Prima di applicare il prodotto è necessario assicurarsi che i materiali costruttivi con i quali si verrà a contatto siano compatibili con il prodotto stesso e tra loro e che non possano danneggiare o alterare le caratteristiche del prodotto • In the case of construction materials that will subsequently be worked at the point where the product has been applied, the user must verify that the...
Open the catalog to page 2Zinc, galvanized iron Sandstone KEY GOOD ADHESION WITHOUT PRIMER NOT SUITABLE RECOMMENDED TEST Linear meters of joint that can be obtained with a 310 ml cartridge Width Width Width Width 1/4" (6 mm) 8 mm (0.31in) 10 mm (0.39 in) 15 mm (0.59in) ± 10 m (32.8 ft) ± 8 m (26.25 ft) ± 6 m (19.68 ft) ± 6 m (19.68 ft) ± 4.5 m (14.76 ft) ± 3 m (9.84 ft) ± 3 m (9.84 ft) ± 2 m (6.56 ft) ± 1.5 m (4.92 ft) ± 1 m (3.28 ft) IDENTIFICATION DATA Polymerization Consistency of mix Specific gravity Film-forming time Setting in 24 hours Acceptable application temperatures Recommended application temperatures Serviceability...
Open the catalog to page 3Powered by TCPDF (www.tcpdf.org) COLOR TABLE Data detection at temperature +73.4°F (+23 °C ), R.H. 50% and with no wind. May vary depending on the specific conditions of the installation site. Form n. 814 Revision n. 0 Date: March 2021 The information and provisions contained in this technical data sheet reflect our best experience. Given the impossibility of directly intervening on the conditions of the work site and execution of the works, they represent indications of a general nature, which are in no way binding on our Company. It is therefore advisable to perform a spot test to check the...
Open the catalog to page 424 Pages
4 Pages
4 Pages
4 Pages
4 Pages
5 Pages
5 Pages
6 Pages
6 Pages
5 Pages
6 Pages
7 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
3 Pages
5 Pages
4 Pages
4 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
4 Pages
6 Pages
6 Pages
3 Pages
2 Pages
4 Pages
2 Pages
3 Pages
6 Pages
2 Pages
2 Pages
2 Pages
5 Pages
3 Pages
2 Pages
3 Pages
2 Pages
4 Pages
4 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
7 Pages
3 Pages
3 Pages
3 Pages
2 Pages
8 Pages
3 Pages
3 Pages
3 Pages
3 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
5 Pages
5 Pages
5 Pages
7 Pages
7 Pages
8 Pages
3 Pages
5 Pages
7 Pages
7 Pages
10 Pages
6 Pages
6 Pages
4 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
9 Pages
9 Pages
7 Pages
11 Pages
100 Pages
4 Pages
2 Pages
17 Pages
21 Pages
34 Pages
100 Pages
25 Pages
2 Pages
113 Pages
12 Pages