HydroCrystal® Technical Specifications Hydro-reactive, active capillary-action, low-cement-content mineral crystallising coating for the restoration and structural waterproofing of concrete structures subject to negative and positive hydrostatic pressure. Seals the capillary pores in the concrete, preventing the penetration of water and moisture. Product description Hydro-reactive mineral crystallising coating with active capillary action and low cement content for the restoration and structural waterproofing of concrete structures subject to negative and positive hydrostatic pressure. By interacting with the moisture present in the substrate, it seals the capillary pores and micro-channels through which water passes in the concrete, transforming the substrate into a structural waterproof barrier. The coating guarantees high resistance to severe chemical attack, direct abrasion and wet-dry cycles. It helps to protect concrete structures from degradation processes, such as carbonation and salt penetration, thereby extending their long-term durability. The crystalline barrier forms within the substrate matrix and is not subject to surface delamination. Specifically designed for waterproofing applications against counterpressure. Classified as 2 (MC), 6 (RC) and 8 (IR) – EN 1504-2 (C) Proprietary formula Hydro-reactive mineral coating with crystallising action Mineral blend under our own licence, offering extended durability under continuous immersion Low Portland cement content (< 30%) Reactive silicates Technical Specification
Open the catalog to page 1High mineral aggregate content HydroCrystal® embodies Litokol’s ongoing scientific progress. It is formulated using innovative raw materials to improve the application experience, enhance safety and reduce environmental impact. CrystalCore® technology Core crystallisation CrystalCore® Crystallising Technology is a chemical treatment which, when applied as an interpenetrating membrane, waterproofs the concrete and extends its service life (longevity). The mineral coating, which undergoes crystallisation, chemically interacts with the moisture present in the concrete, forming a compact internal...
Open the catalog to page 2Technical Specifications
Open the catalog to page 3Concrete and reinforced concrete Heavy masonry and stone masonry Reinforced plasters and concrete screeds Uses Interior - exterior Floors - walls Foundations and retaining walls Basements, lift shafts, service rooms and damp rooms Tanks, reservoirs, channels, outdoor swimming pools and hydraulic Damp substrates (relative humidity <8%) Residential, public, commercial and street furniture Areas subject to heavy footfall and high stress Limitations Refer to national regulations The ambient and surface temperatures must be above +5°C at the time of installation and for 48 hours after application...
Open the catalog to page 4Water resistance under negative pressure >1.5 bar Consistency of the mix Mix preparation Dough proving time Pot life pH of the mixture Specific gravity of the mixture Total thickness (dry) Permissible application temperatures Drying time between the first and second coats Operating temperature Cleaning of equipment Superfluid and thixotropic Water = 22-26% - 4.4-5.2 l/20 kg 5 minutes Smooth steel trowel, roller or brush From +5°C to +35°C 5 hours With water when the product is fresh. Mechanically once the product has hardened. Data recorded at a temperature of +23 °C, 50% RH and in the absence...
Open the catalog to page 5Create transition chamfers at wall-to-wall and wall-to-floor junctions using HydroLevel® 1-30 mixed with BoostGel diluted in water in a 1:1 ratio; before creating the transition chamfer, use a power tool to cut out a suitable recess at the junction, remove any dust and dampen the area. Next, apply the first coat of HydroCrystal® evenly directly onto the substrate using a smooth steel trowel, roller or brush, applying firm pressure to achieve a consistent thickness of approximately 1 mm; coat the entire surface to be waterproofed. It is recommended that the mortar be worked thoroughly into the...
Open the catalog to page 6Powered by TCPDF (www.tcpdf.org) bind our Company. We therefore recommend carrying out a preliminary test to verify the product’s suitability for the intended use; in any case, anyone intending to use it is required to determine whether or not it is suitable for the intended use and, in any event, assumes all liability that may arise from its use. Always refer to the latest updated version of the Technical Data Sheet, available on the website www.litokol.com Specification item The waterproofing of foundations, retaining walls, underground rooms, lift shafts, service rooms, damp rooms, basins,...
Open the catalog to page 73 Pages
3 Pages
3 Pages
3 Pages
3 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
8 Pages
3 Pages
4 Pages
4 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
4 Pages
6 Pages
2 Pages
2 Pages
4 Pages
4 Pages
7 Pages
7 Pages
6 Pages
8 Pages
10 Pages
8 Pages
3 Pages
4 Pages
5 Pages
4 Pages
5 Pages
4 Pages
6 Pages
3 Pages
1 Page
9 Pages
9 Pages
4 Pages
8 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
10 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
8 Pages
10 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
8 Pages
12 Pages
8 Pages
10 Pages
6 Pages
5 Pages
6 Pages
13 Pages
5 Pages
13 Pages
12 Pages
7 Pages
10 Pages
12 Pages
6 Pages