CrackRepair Technical Specifications Solvent-free, two-component structural epoxy crack repair compound for the monolithic repair of cracks and fissures in screeds, renders and concrete. Product description Solvent-free, two-component structural epoxy crack repair compound for the monolithic repair of cracks and fissures in screeds, renders and concrete. Crack Repair has a Fluidotixo consistency, making it suitable for application on both floors and walls. Once cured, it does not prevent the adhesion of high-performance gels based on Litokol technology. It is suitable for fresh-on-fresh joints between concrete and screeds. It has high elasticity and excellent adhesion to both absorbent and nonabsorbent substrates; it does not require auxiliary steel reinforcement. EC1 Plus Gev Emicode A+ Indoor air emissions EPD Environmental Product Declaration Screeds Self-levelling compounds Levelling Compounds Existing tiles Radiant heating systems Concrete and reinforced concrete Fibre-cement sheets Technical Specifications
Open the catalog to page 1Lightweight panels Interior – exterior Floors – walls Overlay Heated screeds Sulphate/anhydrite-based screeds Swimming pools, baths and fountains SPA and Hammam Indoor wet areas (bathrooms, showers) Facades Industrial flooring Residential, public and commercial construction Do not mix partial quantities of the components without using scales; incorrect mixing ratios would result in the product failing to set properly Do not add lime, cement or other foreign materials to the product Do not use on underfloor heating systems that have not been properly prepared; on substrates subject to rising damp...
Open the catalog to page 2Abrasion/wear resistance Impact resistance Adhesion to the substrate Static punching UV resistance Shrinkage Elastic modulus Moisture resistance > 4,000 MPa In-house method Excellent Resistance to temperature fluctuations Excellent Ageing resistance Excellent Preparation of Substrates must be clean, dry, sound, compact, sufficiently cured and free . . . from rising damp. auugu Existing paints or varnishes must be removed and the substrate dust-free. Surface finishes based on lime, cement or plaster applied in a thin layer must be removed and the substrate dust-free. Preparation of the mix Pour...
Open the catalog to page 3with joints of a width appropriate to their size (minimum 2 mm). For grouting in damp areas, we recommend using Starlike® Pro or Starlike® Easy. Take account of any partition or structural joints and provide suitable expansion, partition and perimeter joints. In hot weather, store the product packs in a cool place away from direct sunlight before use Observe the mixing ratio Apply the product at temperatures between +5°C and +30°C The pot life of the mixture is approximately 60 minutes at a temperature of +23°C. It is recommended to mix only the quantity of product that can be used within this...
Open the catalog to page 4Powered by TCPDF (www.tcpdf.org) Product details No. 126 Revision 0 Date: 04 25 Litokol Lab Spa Via G. Falcone 13/1 42048 Rubiera RE Italy Tel. +39 0522 622811 [email protected] www.litokol.com Technical Specifications
Open the catalog to page 53 Pages
3 Pages
3 Pages
3 Pages
3 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
5 Pages
5 Pages
8 Pages
3 Pages
4 Pages
4 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
4 Pages
6 Pages
2 Pages
2 Pages
4 Pages
4 Pages
7 Pages
7 Pages
6 Pages
8 Pages
10 Pages
8 Pages
7 Pages
3 Pages
4 Pages
5 Pages
4 Pages
5 Pages
4 Pages
6 Pages
3 Pages
1 Page
9 Pages
9 Pages
4 Pages
8 Pages
3 Pages
5 Pages
5 Pages
4 Pages
10 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
4 Pages
4 Pages
8 Pages
10 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
10 Pages
8 Pages
12 Pages
8 Pages
10 Pages
6 Pages
5 Pages
6 Pages
13 Pages
5 Pages
13 Pages
12 Pages
7 Pages
10 Pages
12 Pages
6 Pages