li ndab | ceiling diffusers Plain diffuser CRL is a circular diffuser with an unperforated adjustable face plate. CRL can be used both for supply and exhaust air. The diffuser can be switched between horizontal and vertical supply air, and is therefore suitable for the horizontal supply of cooled air or vertical supply of heated air. Installing a CRL diffuser in a plenum box type MBB can help to achieve a stable airflow to the diffuser as well as realise the potential for individual adjustment. It is also possible to install a damper directly in the diffuser to enable adjustment without a box. * ØU = Ceiling grid opening Dispersal patterns CRL is supplied with vertical supply air as standard. The dispersal pattern can be changed to horizontal supply air by moving the face plate. • Suitable for both supply and exhaust air • Suitable for horizontal or vertical supply air patterns • A damper can be installed on the diffuser to achieve adjustment The face plate can be removed to enable cleaning of internal parts or to gain access to the duct or plenum box. The visible parts off the diffuser can be wiped with a damp cloth. Order code Product Type CRL Grille box: Face plate: Standard finish: Standard colour: Aluminium Galvanised steel Powder-coated White RAL 9010, gloss 30 The diffuser is available in other colours. Please contact Lindab’s sales department for further information. We reserve the right to make changes without prio
Open the catalog to page 1lindab | ceil ing di ffusers Plain diffuser Accessories Order code - accessoreies Product Type Size USING CRL + MBB => ALWAYS USE MBZ * Using accessory MBZ the H dimension will increase: Ød2 = 100 - 200 mm => H +40 mm Ød2 = 250 - 315 mm => H +60 mm Ød2 = 400 mm => H +80 mm Order code Product Type Function S = Supply air E = Exhaust We reserve the right to make changes without prior notice
Open the catalog to page 2li ndab | ceiling diffusers Plain diffuser Technical data Capacity Air flow qv [l/s] and [m3/h], total pressure Δpt [Pa], throw l0.2 [m] and sound power level LWA [dB(A)] can be seen in the diagrams. The throw is specified at a terminal velocity of 0.2 m/s. Diagram below shows throw l0.2 for horizontal supply air. CRL Frequency-related sound effect level The sound effect level in the frequency band is defined as LWA+Kok. Kok values are specified in charts beneath the diagrams on the following pages. Kok values for CRL without a box are available on request. Quick selection, supply air...
Open the catalog to page 3lindab | ceiling diffusers Plain diffuser Technical data Throw \0 2/ turning point l0.o Throw l02 [m] is specified at a speed of 0.2 m/s. Turning point l0.o [ml is specified for +5 K, +10 K respectively. We reserve the right to make changes without prior notice
Open the catalog to page 4li ndab | ceiling diffusers Plain diffuser Technical data CRL 100 + MBB - Supply air pt [Pa] CRL-100+MBB-100-100-S 250 200 13 14 15 16 17 18 We reserve the right to make changes without prior notice
Open the catalog to page 5lindab | ceiling diffusers Plain diffuser Technical data We reserve the right to make changes without prior notice
Open the catalog to page 6lindab | ceiling diffusers Plain diffuser Technical data We reserve the right to make changes without prior notice
Open the catalog to page 7lindab | ceil ing di ffusers Plain diffuser Technical data CRL + MBB - Supply air Correction vertical supply air, sound power level ( LWA ) and pressure loss ( Δpt ) Correction factor We reserve the right to make changes without prior notic
Open the catalog to page 8lindab | ceiling diffusers Plain diffuser Technical data We reserve the right to make changes without prior notice
Open the catalog to page 9lindab | ceil ing di ffusers Plain diffuser Technical data We reserve the right to make changes without prior notice
Open the catalog to page 10li ndab | ceiling diffusers Plain diffuser Technical data CRL 200 + MBB - Exhaust air pt [Pa] CRL-200+MBB-200-200-E 250 200 We reserve the right to make changes without prior notice
Open the catalog to page 11lindab | ceil ing di ffusers Plain diffuser Technical data We reserve the right to make changes without prior notice
Open the catalog to page 12All Lindab catalogs and technical brochures
-
Lindab Group Q3 2017
22 Pages
-
roof drainage system
24 Pages
-
roof drainage system inspiration
16 Pages
-
roof drainage system assembly
16 Pages
-
Plenum box - H
1 Pages
-
Facade Cassettes
28 Pages
-
sandwich wall panels
1 Pages
-
Lindab Tile Effect Roofing
16 Pages
-
Exterior Wall Profiles
14 Pages
-
Standing Seam Roofing
14 Pages
-
Garage doors
12 Pages
-
Sandwich panels
10 Pages
-
Rainwater systems
18 Pages
-
Corporate brochure
15 Pages
-
Fasteners
8 Pages
-
Flashings
8 Pages
-
Facade cassettes:
8 Pages
-
Comfort Water
461 Pages
-
Product selector
24 Pages
Archived catalogs
-
profiled sheeting
24 Pages
-
Tile effect roofing
14 Pages
-
Catalogue Ventilation 2010
678 Pages
-
Lindab Group Presentation
36 Pages