Catalog excerpts
Energy Management The Smart Choice for Lighting Control and Energy Solutions
Open the catalog to page 1For most companies, the last time they reaped significant financial benefit from a change in their lighting systems was with an upgrade to more efficient lamps and electronic ballasts. But a lot has changed since then. Now, in virtually every business, there is an opportunity to significantly reduce existing lighting costs further by adopting newly developed energy management control systems. WHY ADOPT ENERGY MANAGEMENT CONTROLS NOW? IT’S THE CODE. Energy codes are now the law of the land. From the ASHRAE 90.1 Energy Standard and IECC, to LEED, CA Title 20/24 and more, federal and state...
Open the catalog to page 2Sensing Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Energy Harvesting Wireless Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Wall Switch Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Line Voltage Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Low Voltage Sensors . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 3LEVITON COMMERCIAL LIGHTING CONTROL SOLUTIONS Every industry, facility and application has different lighting control needs. Some needs can be met with a simple solution, such as an occupancy sensor, while others require the advanced customization and control of GreenMAX® and Sector®. Leviton offers a spectrum of lighting control and energy management strategies to meet any application: • Occupancy Sensing Control - A complete line of PIR, ultrasonic and multi-technology occupancy sensors • Room Control - LevNet RF™ Energy Harvesting Solutions, Classroom Lighting Control Solutions and...
Open the catalog to page 5Lighting Control Solutions | Commercial Leviton Lighting Control Solutions can be selected and tailored to commercial, institutional and industrial applications including: • Retail spaces • Single, small, midsize and large office complexes • Municipalities • K-12 schools and college campuses • Prison and correctional facilities • Museums, convention centers and lecture halls • Houses of worship • Health care and hospital facilities • Shopping malls and complexes • Warehouses • Airports • Restaurants • National parks and monuments • Government facilities Leviton Lighting Control Solutions...
Open the catalog to page 6From Task Lighting (20%) From Daylight Harvesting (35%) From Occupancy Sensors (18%) Source: Midwest Energy Efficiency Alliance BENEFITS FROM DAYLIGHT HARVESTING • Energy savings • Reduce peak electric load • Allow continued operation during power outages • Connecting people to their external environment • Improved productivity and health Lighting, heating and air conditioning account for up to 70% of all energy being consumed in today’s modern buildings. Daylight harvesting controls are the best way to optimize the low cost, natural resource of daylight. Key energy saving points for...
Open the catalog to page 7Lighting Control Solutions | Commercial OCCUPANCY SENSING CONTROL Occupancy sensors deliver one of the simplest and most effective methods of reducing energy usage. Basic rooms such as restrooms, private offices, medical exam rooms and meeting rooms will see a significant drop in lighting costs when an occupancy sensor is installed. GOOD SOLUTION OCCUPANCY SENSOR WITH AUTO ON/OFF CONTROL PROBLEM: Facility contains rooms that are sporadically occupied and do not require manual override capabilities. SOLUTION: A single auto ON/OFF occupancy sensor takes the burden of lighting control off the...
Open the catalog to page 8Power Pack OCCUPANCY SENSOR MULTI-ZONE/BI-LEVEL SWITCHING SOLUTION PROBLEM: Room is used in multiple applications, and the same levels of light are not always desired. SOLUTION: By dividing a space into zones, lighting becomes more versatile. Multi-zone/bi-level switching, controlled by an occupancy sensor, allows occupants to accommodate A/V presentations, computer usage and other tasks where full overhead lighting is not desired. The integration of Occupancy Sensors OSCxx-Rxx with HVAC relay lends the option of incorporating heating and cooling systems into the occupancy sensor control...
Open the catalog to page 9Lighting Control Solutions | Commercial 10 BEST SOLUTION OCCUPANCY SENSOR STAIRWELL SOLUTION PROBLEM: Stairwell contains two relays that are always ON regardless of occupied state and available natural light. Relays burnout quickly adding to increased energy costs. SOLUTION: By using the ODC Dual Relay Multi-Technology Occupancy Sensors, load controls are balanced with alternating relays while taking Daylight Harvesting and natural light into account to extend the life of the relays. • Both loads will automatically turn ON when occupancy is detected • Load 1 and load 2 alternate between ON...
Open the catalog to page 10Leviton Room Control solutions build on the foundation of occupancy sensing to add value and convenience for facilities. Room controls introduce daylight harvesting capabilities, which takes advantage of natural light entering a space from windows, skylights and other open spaces. Utilizing daylight to evenly light a room while improving productivity and user experience diminishes the amount of overhead lighting necessary to light the space. GOOD SOLUTION LEVNET RF MULTI-LOCATION SWITCHING SOLUTION PROBLEM: Facility wants to implement an occupancy sensing and daylight harvesting solution,...
Open the catalog to page 11Lighting Control Solutions | Commercial GOOD SOLUTION miniZ INTELLIGENT DAYLIGHT HARVESTING DUAL-ROOM SOLUTIONS PROBLEM: Similar office spaces share fixtures on separate zones, but will be used by occupants at different times. SOLUTION: The miniZ Dual Room system allows separate spaces to be controlled on separate zones. Connected occupancy sensors and photocells account for different levels of light and/or occupancy in each unique space. miniZ switching solutions keep lights OFF when the room is unoccupied. The miniZ switching module controls two zones, which allows for switching the...
Open the catalog to page 12All LEVITON Lighting catalogs and technical brochures
-
Educational Solutions
38 Pages
-
MDU Solutions
30 Pages
-
Hospitality Solutions
32 Pages
-
Healthcare Solution
40 Pages
-
Food & Beverages Solutions
28 Pages
-
Rhino-Hide Multi-Pin Connectors
36 Pages
-
Rhino-Hide Single Pole Devices
60 Pages
-
Bitwise AV Controls Solutions
16 Pages
-
Catalog - Network Solutions 2015
260 Pages
-
Catalog - Renu
20 Pages
-
renu in a snap!
20 Pages
-
GFCI Products Buying Guide
7 Pages
-
Smart Selling. Smart Solutions.
226 Pages
-
Architectural Lighting Controls
34 Pages
-
Entertainment Products
48 Pages
-
Connected Home Catalog 2014
106 Pages
-
L-300 Catalog
816 Pages
Archived catalogs
-
Entertainment Products
19 Pages
-
Residential Catalog
278 Pages