Thermoplastic Waterstops
Open the catalog to page 1Concerning the actual state of the DIBt (german institute of civil engineering) in consultation with the authorities of construction inspection of the federal states created building regulations, for protection against pressing water, not pressing water and soil humidity, it´s only allowed to use waterstops in accordance with : DIN 18541 thermoplastic waterstops, weldable Elastomeric waterstops, vulcanisable or waterproofing systems with AbP (general construction supervision certificate) In DIN 18197 planning, dimensioning, conditioning, handling and the installation of waterstops are...
Open the catalog to page 2Construction joint waterstops for sealing of construction joints in watertight concrete Combination construction joint waterstops, (KAB...) floor/wall without floor setting edge Construction joint waterstops, internal, reinforced, (SFA... / ISA ...) Construction joint waterstops, internal, (A...) Construction joint waterstops, external, (AA...) Joint tubes © LESCHUPLAST GLT for precise controlling and sealing of shrinkage cracks in watertight concrete Expansion joint waterstops for sealing of expansion joints in watertight concrete Waterstops for high demands (A...+ D...) Expansion joint...
Open the catalog to page 3Combination construction joint waterstop (KAB) the simple, easy and safe sealing of construction joints Functional principle water pressure marking strip ribbed sealing part swelling rubber part The KAB - combination construction joint waterstop is a waterstop with an integrated TPE - round swelling rubber profile used for the sealing of construction joints in concrete structures. The KAB - combination construction joint waterstop consists of a PVC-P material and a splash water protected TPE -round swelling rubber profile. The sealing capabilities of the KAB - combination construction joint...
Open the catalog to page 4Combination construction joint waterstop (KAB) the simple, easy and safe sealing of construction joints The marking strip of 2,5 cm width is located at a height of 2,5 cm up to 5,0 cm and serves as an installation control. The max. linking depth of the profile bottom with the swelling rubber is 5,0 cm. Joints can be connected and installed in different ways: With terminal strips, which were especially developed for combination construction joint waterstops. Basic principle are 3 TPE - swelling rubber profiles with a capacity for high volume expansion and terminal strips of 2 mm thickness,...
Open the catalog to page 5Construction joint waterstops, internal, with extruded reinforcement and fixing loops, black, LECOTRIL DIN 18541 reinforcing by harder adjusted PVC P cords 4,5 Construction joint waterstops with fixing loops are reinforced one - sided with harder adjusted PVC P cords and have fixing loops on both edges of the waterstop. The protruding loops are for fastening the waterstop to the reinforcement (clamps are not required). Construction joint waterstops, internal, with internal flat steel bar - reinforcement, black, LECOTRIL DIN 18541 3,5 reinforcing by internal flat steel bar 4,0
Open the catalog to page 6Construction joint waterstops, internal, black, LECOTRIL DIN 18541 Construction joint waterstops, internal, black, Standard Specification with AbP thickness of expansion part comparable profiles according to DIN 18541 total width width of expansion part PVC-P Standard Specification
Open the catalog to page 7Construction joint waterstops,external,
Open the catalog to page 8Angle type profiles black, LECOTRIL DIN 18541, part 2 without illustration: anchoring ribs internal anchoring ribs external anchoring ribs internal/external 120 without illustration: anchoring ribs internal anchoring ribs external anchoring ribs internal/external 165 Construction joint waterstops, external, black, Standard Specification with AbP PVC-P Standard Specification total width anchoring ribs width of thickness of comparable profiles expansion part expansion part height quantity according to DIN 18541
Open the catalog to page 9Joint tube for sealing of shrinkage- and construction joints in watertight concrete walls crack inducer controlling of cracks (predetermined breaking point) sealing of cracks by anchoring ribs reinforcement with PVC-U-pipe quick and efficient installation performance-proven by long experience crack inducer reinforcement with PVC-U-pipe for concrete cross sections from 24 up to 35 cm for concrete cross sections from 35 up to 50 cm for concrete cross sections from 17 up to 24 cm (especially for pre-cast double walls) Installation example trapezoid ledge combination construction joint...
Open the catalog to page 10Joint tube for sealing of shrinkage- and construction joints in watertight concrete walls Cross section of a multifloor basement garage in watertight concrete construction joint waterstop, external 2x3 Installation instructions Before installation, the joint tube has to be-cut inacross to the smooth crack inducer. The joint tube has to be cut into lengths according to total height of the walls, on building site. additional reinforcement against shrinkage in tube area joint tube Attaching the joint tube on top of KAB, which is installed for sealing the connection floor level/wall. Pay...
Open the catalog to page 11Joints for high demands black, LECOTRIL DIN 18541, part 2
Open the catalog to page 12Expansion joint waterstops, internal, black, LECOTRIL DIN 18541 Expansion joint waterstops, internal, black, Standard Specification with AbP comparable profiles according to DIN 18541 total width width of expansion part thickness of expansion part PVC-P Standard Specification
Open the catalog to page 13Expansion joint waterstops, internal, black, LECOTRIL DIN 18541 Expansion joint waterstops, internal, with extruded reinforcement and fixing loops, black, LECOTRIL DIN 18541 4,0 The expansion joint waterstops with fixing loops are reinforced one sided with harder adjusted PVC - P cords and have fixing loops on both edges of the waterstop. The PVC - loops consist of high impact resisting harder adjusted PVC - P. They have a thickness of 6 mm and stabilise the waterstop. The loops are arranged outside the expansion part, which keeps the expansion part free. reliable fastening quick...
Open the catalog to page 14Expansion joint waterstops, external,
Open the catalog to page 15Angle type profiles black, LECOTRIL DIN 18541, part 2 anchoring ribs external anchoring ribs internal/external anchoring ribs external anchoring ribs internal/external Expansion joint waterstops, external, black, Standard Specification with AbP